Dose optimization in computed tomography / (Record no. 72427)

MARC details
000 -LEADER
fixed length control field 02600cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032315.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190615s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.M.Sc.2018.Mo.D
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mona Mohamed Attia Elsayed Eletr
245 10 - TITLE STATEMENT
Title Dose optimization in computed tomography /
Statement of responsibility, etc. Mona Mohamed Attia Elsayed Eletr ; Supervised Anwar Abdelazim Elsayed , Haba Mohamed Fahmy Abdelbaky , Hossam Mahmoud Yassien
246 15 - VARYING FORM OF TITLE
Title proper/short title الجرعة المثلى في التصوير المقطعي
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mona Mohamed Attia Elsayed Eletr,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 63 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. Background: CT imaging is increasingly used in the field of medical diagnosis because of its advantages in the diagnosis, but the patient is given a high dose of radiation that does not match his weight and age because there is no optimal radiation dose source. Aim of the study: The aim of the present study is to make a comparative study for the measured radiation doses of the CT scans for pediatric head examinations. Materials and methods: Data obtained from 6 Egyptian hospitals is compared with the international dose reference levels, upon which, an optimization of the radiation doses can be deduced. The total sample size of this study is 295 patients having different CT scan examinations. The dose length product (DLP) and the volume CT dose index (CTDIvol) are calculated for each examination using the main parameters collected from the CT scanner, and by multiplying DLP by a conversion factor; the effective dose was also calculated. Results: The present results of DLP and CTDIvol show that sometimes the dose in Egypt CT examinations was lower and sometimes higher than published results from other countries. The present data from Egyptian CT scans indicated that the average DLP values for head examinations for pediatric patients aged {u2264} 5 are higher than the international dose reference levels
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Computed tomography
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CTDIvol
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term DLP
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Anwar Abdelazim Elsayed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Haba Mohamed Fahmy Abdelbaky ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hossam Mahmoud Yassien ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.M.Sc.2018.Mo.D 01010110078430000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.M.Sc.2018.Mo.D 01020110078430000 22.09.2023 CD - Rom 78430.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library