Smart touch radiofrequency catheter ablation versus cryoballoon ablation of pulmonary veins in patients with paroxysmal AF / (Record no. 72453)

MARC details
000 -LEADER
fixed length control field 02979cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032316.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190615s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.09.Ph.D.2018.Wa.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Walid Shehatta Hassan
245 10 - TITLE STATEMENT
Title Smart touch radiofrequency catheter ablation versus cryoballoon ablation of pulmonary veins in patients with paroxysmal AF /
Statement of responsibility, etc. Walid Shehatta Hassan ; Supervised Sherif Hamed , Kahled Hussein , Motaz Elhalag
246 15 - VARYING FORM OF TITLE
Title proper/short title الذبذبة الأذينية ما بين الكى الحرارى بموجات الراديو مستخدما قسطرة ذات خاصية إستشعار الضغط والكى بالتبريد
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Walid Shehatta Hassan ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 186 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Critical Care Medicine
520 ## - SUMMARY, ETC.
Summary, etc. Aims Evaluation of the safety and efficacy of PVI in PAF patients using two new different technologies, cryoballoon ablation and RFA with contact force-sensing catheters. Methods and results We performed a prospective single centre non-randomized controlled clinical trial that was conducted during the period between January 2016 and June 2018 in Critical Care Medicine Department{u2013} Cairo University.Twenty patients were enrolled in this study and were subjected to standardized PVI using RFA with CF sensing catheter (Thermocool® SmartTouch{u2122}, Biosense Webster (CF group, n=10 patients) and CB ablation (Arctic Front Advance{u2122}, Medtronic)(CB group n=10 patients).Twelve months follow up was used to assess procedure long term outcome and complications rate. Procedure duration was significantly shorter for CB group than for CF group (171.7+15.24 vs. 199.3+18.94 min, P = 0.002), however fluoroscopy duration and X-ray exposure were longer in CB group than CF group , however was not statistically significant (P = 0.1 and P = 0.22, respectively). Overall complication rate was similar in both groups: 2 (20%) in each group. Transient right phrenic nerve palsy occurred only in CB group (1 patient,10% vs none in the CF group); and transient ischemic acute stroke occurred only in one patient of the CB group (10% vs none in the CF group) ,severe non-lethal complications (Tamponade, and the uncommon complication, entrapment of circular mapping catheter into mitral valve ) occurred only in CF group (2 patients, 20%)
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Paroxysmal atrial fibrillation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Pulmonary veins
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Radiofrequency
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Kahled Hussein ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Motaz Elhalag ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sherif Hamed ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.09.Ph.D.2018.Wa.S 01010110078439000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.09.Ph.D.2018.Wa.S 01020110078439000 22.09.2023 CD - Rom 78439.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library