Accuracy of guided implant placement using double versus triple scan protocol in completely edentulous patients : (Record no. 72485)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02704cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223032317.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 190618s2018 ua do f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2018.Mo.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mostafa Mohamed Saleh Elmaghraby |
245 10 - TITLE STATEMENT | |
Title | Accuracy of guided implant placement using double versus triple scan protocol in completely edentulous patients : |
Remainder of title | Randomized clinical trial / |
Statement of responsibility, etc. | Mostafa Mohamed Saleh Elmaghraby ; Supervised Amal Fathy Kaddah , Amr Hosny Elkhadem |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دقة وضع الزرعه الموجهة باستخدام البروتوكول الثنائي مقابل البروتوكول الثلاثي في المرضى عديمي الأسنان |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mostafa Mohamed Saleh Elmaghraby , |
Date of publication, distribution, etc. | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 109 P. : |
Other physical details | charts , photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The present study was designed to compare the accuracy of guided implant placement by double scan technique versus triple scan technique. This study was conducted on twelve patients recruited from the Outpatient Clinic of the Faculty of Oral and Dental Medicine Cairo University. For each patient implants were placed in mandible arch using computer aided surgical guides. patients were divided into two groups: First group: implants placement by triple scan protocol. Second group: implants placement by double scan protocol. CBCT scanning with virtual implant planning were used to develop a computer based surgical guide which was used to place the implant according to the suggested protocols. Patients were scanned by C.B.C.T after two weeks from surgery to compare the accuracy of planned position and actual position of implants placement by double scan protocol versus triple scan protocol. Linear and angular deviations were measured between planned and actual position in both groups double scan and triple scan protocol. After results were tabulated and statistically analyzed, there was no statistically difference in linear and angular deviation between two groups of scanning protocols; double scanning and triple scanning protocol |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Double scan protocol |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Guided implant placement |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Triple scan protocol |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amal Fathy Kaddah , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amr Hosny Elkhadem , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Rania |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2018.Mo.A | 01010110078360000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2018.Mo.A | 01020110078360000 | 22.09.2023 | CD - Rom | 78360.CD |