Clinical and radiographical evaluation of new bioactive dentine substitute (Biodentine) versus glass ionomer cement in treatment of very deep carious lesions : (Record no. 73415)

MARC details
000 -LEADER
fixed length control field 02971cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032344.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190820s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.03.Ph.D.2018.Om.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Omnia Magdy Moustafa
245 10 - TITLE STATEMENT
Title Clinical and radiographical evaluation of new bioactive dentine substitute (Biodentine) versus glass ionomer cement in treatment of very deep carious lesions :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Omnia Magdy Moustafa ; Supervised Mohamed Riad Farid , Rasha Raafat Hassan
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم سريري و بأستخدام الأشعه لبديل العاج النشط بيولوجيا (بيودينتين) في مقابل المتماثرات الشاردة الزجاجية في علاج نخور الاسنان العميقه جدا :
Remainder of title تجربة عشوائية مضبوطة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Omnia Magdy Moustafa ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 84 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry
520 ## - SUMMARY, ETC.
Summary, etc. This study was conducted to compare postoperative hypersensitivity in new bioactive dentine substitute (Biodentine) verses Glass Ionomer cement in treatment of very deep carious lesions. A total of 120 teeth of patients who fulfilled the inclusion criteria were selected to participate in the study. Then they were divided into two main groups (A1 receiving Fuji IX) and (A2 receiving Biodentine). Teeth with deep caries undergone caries removal with hand or rotary instrument after rubber dame isolation and the tested base materials were placed in the base of the cavity then composite were placed over as a final restoration. Postoperative hypersensitivity (using thermal test and percussion test) and periapicalpathosis (using digital periapical radiograph) were tested in this period at the baseline (T0), after one week (T1), after three months (T3) and after six months (T6). After follow up period only 98 teeth were statistically analyzed using (SPSS) version. 20. Results showed that both materials have the same effect postoperatively on the pulpal tissues confirmed with thermal, percussion tests and with digital radiograph. -Under the limitations of this study we concluded that: 1-Fuji IX and biodentine is considered clinically effective base material in treatment of deep carious lesions.2-Both materials are capable of maintaining pulp vitality in teeth with deep carious lesions
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Biodentine
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Glass ionomer cement
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Very deep carious lesions
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Riad Farid ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Rasha Raafat Hassan ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.03.Ph.D.2018.Om.C 01010110079095000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.03.Ph.D.2018.Om.C 01020110079095000 22.09.2023 CD - Rom 79095.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library