header

Evaluation of post-operative sensitivity of bulk fill resin composite versus the Nano resin composite : (Record no. 75123)

MARC details
000 -LEADER
fixed length control field 03110cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032435.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191111s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.03.Ph.D.2017.Sa.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Sarah Mahmoud Hussien Afifi
245 10 - TITLE STATEMENT
Title Evaluation of post-operative sensitivity of bulk fill resin composite versus the Nano resin composite :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Sarah Mahmoud Hussien Afifi ; Supervised Mohamed Riad Farid , Mohamed Foaud Haridy
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم حساسية ما بعد الحشوات بمادة الرانتنج بتفنية الكتلة مقابل الرانتنج المعدل بالنانو تكنولوجي :
Remainder of title تجربه اكلينيكيه عشوائيه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Sarah Mahmoud Hussien Afifi ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 81 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry
520 ## - SUMMARY, ETC.
Summary, etc. In this present study there is no difference in postoperative sensitivity between a two-step etch-and-rinse adhesive and one-step self-etch adhesive strategies used under different placement techniques of composite resins to restore occlusal preparations in permanent molars.The clinical technique may play a more important role in postoperative sensitivity than the type of adhesive. The results of the present study are in line with a recent systematic review of the literature (Reis A et al., 2015),that systematic review concluded that the type of adhesive strategy used in bonding procedures in posterior composite resin restorations does not influence the risk and intensity of postoperative sensitivity immediately after the restorative procedure. The results of postoperative sensitivity in this study were in agreement with (Blanchard et al 2013) who concluded that the change in greatest sensitivity was associated with the type of dentin bonding agent used. This result was in favor with (Costa et al., 2017) (Ermis et al., 2009) (Cassetti and Martin 2006) (Jorge Perdigao et al., 2003) they stated that the clinical technique may be more relevant for the development of postoperative sensitivity than is the type of adhesive itself. Academic environment versus clinical practice setting: Finally, the limitations of the present study design; the present study was conducted in a university setting in which restorations are placed under ideal conditions to produce restorations as near perfect as possible, moisture control was usually done cotton rolls and saliva ejector, preventing contamination of the operative field
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Bulk fill resin
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Nano resin composite
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Post-operative sensitivity
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Foaud Haridy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Riad Farid ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.03.Ph.D.2017.Sa.E 01010110079871000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.03.Ph.D.2017.Sa.E 01020110079871000 22.09.2023 CD - Rom 79871.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library