Oral health related quality of life and peri-implant condition in single implant mandibular overdenture retained by CM LOC versus ball attachment : (Record no. 75401)

MARC details
000 -LEADER
fixed length control field 03052cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032445.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191123s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.Ph.D.2019.Ma.O
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Marwa Abdelaal Mohammed
245 10 - TITLE STATEMENT
Title Oral health related quality of life and peri-implant condition in single implant mandibular overdenture retained by CM LOC versus ball attachment :
Remainder of title A randomized controlled trial /
Statement of responsibility, etc. Marwa Abdelaal Mohammed ; Supervised Mahmoud Mokhtar Elfar , Nora Mohamed Cheta , Ahmed Emad Fayyad
246 15 - VARYING FORM OF TITLE
Title proper/short title و المرفق الكروى CM LOC جودة الحياة المرتبطة بصحة الفم و تفاعل الانسجة الرخوة فى الاطقم المحملة على زرعة واحدة باستخدام مرفق :
Remainder of title تجربة سريرية عشوائية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Marwa Abdelaal Mohammed ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 120 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Single implant mandibular overdenture had been reported to achieve satisfactory patient centered results. Two groups (Ball and CM LOC attachments) were chosen to retain the over-denture. 30 subjects were recruited for non-submerged healing protocol. Implants were installed based on CBCT planning and after patients{u2019} approval confirmed by a written consent. A healing cap was left for three months after which randomization was done prior to attachment pick up to select from either ball or CM LOC attachments OHIP-EDENT which is a type of oral health related quality of life and peri-implant soft tissue reactions were reported at 3,6,9, &12 months interval of time. Results had shown statistically insignificant results between the two groups regarding the OHRQOL although CM LOC attachment had expressed relatively higher satisfaction compared to ball. Regarding soft tissue reactions, gingival inflammation and plaque accumulation were more observed around and over ball respectively. expressing relatively worse results than that of CM LOC attachment. The results for the different domains of the OHRQOL suggested that the replacement of CDs with mandibular overdentures retained by a single implant caused immediate improvements in decreased oral pain and discomfort, late improvement in oral function (mastication), and no influences on physiological or social aspects of discomfort or disability over a 1-year period regardless of the attachment type
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CMLOC
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Oral health
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Quality of life
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Emad Fayyad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Mokhtar Elfar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nora Mohamed Cheta ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.Ph.D.2019.Ma.O 01010110080168000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.Ph.D.2019.Ma.O 01020110080168000 22.09.2023 CD - Rom 80168.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library