Assessment of the accuracy of surgical guide designed from cbct with different voxel sizes in computer guided implantology : (Record no. 75483)

MARC details
000 -LEADER
fixed length control field 02988cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032448.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191126s2019 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2019.Mo.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammed Mohammed Ahmed Elhag Ibrahim
245 10 - TITLE STATEMENT
Title Assessment of the accuracy of surgical guide designed from cbct with different voxel sizes in computer guided implantology :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Mohammed Mohammed Ahmed Elhag ; Supervised Mushira M. Dahaba , Ahmed M. Abdalsamad
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم دقة الدليل الجراحى المصمم من التصوير المقطعى بالحاسوب مخروطى الشعاع باستخدام عناصر حجمية مختلفة فى زرع الأسنان بمعاونة الحاسوب :
Remainder of title تجربة سريرية عشوائية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohammed Mohammed Ahmed Elhag Ibrahim ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 72 P. :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Objectives:The present study was designed to assess the effect of CBCT with different voxel sizes on the accuracy of surgical guide fabrication on computer guided implantolog. Material and methods:This study was conducted on eight patients selected from outpatient clinic, Faculty of dentistry, Cairo university. The patients were divided into two groups. One group received dental implants using surgical guides designed from CBCT with 0.2 mm voxel size while the other group received dental implants using surgical guides designed from CBCT with 0.4 mm voxel size. The surgical guides were designed using bluesky bio software. The patients were asked for post-operative CBCT to compare the accuracy the surgical guide. Linear and angular deviations were measured between planned and actual position in both groups. The results were tabulated and statistically analyze.Results:Surgical guides manufactured with CBCT of 0.2 mm voxel size showed statistically significantly lower median linear and angular deviation than surgical guides manufactured with CBCT of 0.4 mm voxel in BL direction. While there was no statistically significantly difference between the two groups in linear and angular deviation in MD direction. Conclusion: There was no clinical significantly clinical difference in linear and angular accuracy between surgical guides manufactured from CBCT with voxel size either 0.2mm or 0.4 mm
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Computer guided implantology
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Surgical guides
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Abdalsamad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mushira Mohamed Dahaba ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2019.Mo.A 01010110079975000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2019.Mo.A 01020110079975000 22.09.2023 CD - Rom 79975.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library