Assessment of the accuracy of surgical guide designed from cbct with different voxel sizes in computer guided implantology : (Record no. 75483)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02988cam a2200337 a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | EG-GiCUC |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250223032448.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 191126s2019 ua do f m 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | EG-GiCUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GiCUC |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| 049 ## - LOCAL HOLDINGS (OCLC) | |
| Holding library | Deposite |
| 097 ## - Thesis Degree | |
| Thesis Level | M.Sc |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Classification number | Cai01.09.13.M.Sc.2019.Mo.A |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Mohammed Mohammed Ahmed Elhag Ibrahim |
| 245 10 - TITLE STATEMENT | |
| Title | Assessment of the accuracy of surgical guide designed from cbct with different voxel sizes in computer guided implantology : |
| Remainder of title | Randomized clinical trial / |
| Statement of responsibility, etc. | Mohammed Mohammed Ahmed Elhag ; Supervised Mushira M. Dahaba , Ahmed M. Abdalsamad |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | تقييم دقة الدليل الجراحى المصمم من التصوير المقطعى بالحاسوب مخروطى الشعاع باستخدام عناصر حجمية مختلفة فى زرع الأسنان بمعاونة الحاسوب : |
| Remainder of title | تجربة سريرية عشوائية |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Cairo : |
| Name of publisher, distributor, etc. | Mohammed Mohammed Ahmed Elhag Ibrahim , |
| Date of publication, distribution, etc. | 2019 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 72 P. : |
| Other physical details | charts , photographs ; |
| Dimensions | 25cm |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Objectives:The present study was designed to assess the effect of CBCT with different voxel sizes on the accuracy of surgical guide fabrication on computer guided implantolog. Material and methods:This study was conducted on eight patients selected from outpatient clinic, Faculty of dentistry, Cairo university. The patients were divided into two groups. One group received dental implants using surgical guides designed from CBCT with 0.2 mm voxel size while the other group received dental implants using surgical guides designed from CBCT with 0.4 mm voxel size. The surgical guides were designed using bluesky bio software. The patients were asked for post-operative CBCT to compare the accuracy the surgical guide. Linear and angular deviations were measured between planned and actual position in both groups. The results were tabulated and statistically analyze.Results:Surgical guides manufactured with CBCT of 0.2 mm voxel size showed statistically significantly lower median linear and angular deviation than surgical guides manufactured with CBCT of 0.4 mm voxel in BL direction. While there was no statistically significantly difference between the two groups in linear and angular deviation in MD direction. Conclusion: There was no clinical significantly clinical difference in linear and angular accuracy between surgical guides manufactured from CBCT with voxel size either 0.2mm or 0.4 mm |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Additional physical form available note | Issued also as CD |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Computer guided implantology |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Implant |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Surgical guides |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ahmed Mohamed Abdalsamad , |
| Relator term | |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mushira Mohamed Dahaba , |
| Relator term | |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
| 905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
| Cataloger | Nazla |
| Reviser | Revisor |
| 905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
| Cataloger | Samia |
| Reviser | Cataloger |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.13.M.Sc.2019.Mo.A | 01010110079975000 | 22.09.2023 | Thesis | ||
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.13.M.Sc.2019.Mo.A | 01020110079975000 | 22.09.2023 | CD - Rom | 79975.CD |