Comparative study between dynamic hip screw with trochanteric stabilizing plate versus short gamma nail in management of unstable trochanteric fractures : (Record no. 77338)

MARC details
000 -LEADER
fixed length control field 03420cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032545.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200823s2020 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.25.M.Sc.2020.Ra.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ramy Emad Younan
245 10 - TITLE STATEMENT
Title Comparative study between dynamic hip screw with trochanteric stabilizing plate versus short gamma nail in management of unstable trochanteric fractures :
Remainder of title Regarding radiological and functional outcome /
Statement of responsibility, etc. Ramy Emad Younan ; Supervised Mohamed Kamel Goda , Mohamed Aboelsoud , Elsayed Mohamed Kassem
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة مقارنة بين برغى الورك الديناميكى مع صفيحة التثبيت المدببة مقابل مسمار جاما القصير فى عظم الفخد غير المستقر المكسور
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ramy Emad Younan ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 112 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Orthopedics Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Objective: the aim of this study is to compare between dynamic hip screw with trochanteric stabilizing plate and short gamma nail in unstable trochanteric fractures regarding functional and radiological outcome. Introduction: Intertrochanteric femoral fractures are common in the elderly. They account for more than 50% of all hip fractures and are a common orthopedic problem in this age group (1).They are extra capsular fractures of the proximal femur between the greater and lesser trochanters. Due to the mortality and significant morbidity associated with these fractures, they constitute a major challenge to all orthopedic surgeons (2), (3). There are many classification systems for these fractures.The most classic one is Evans classification which divides them into stable and unstable fractures based on the fracture pattern (4). Management of stable trochanteric femoral fractures by dynamic hip screw (DHS) is proven to be the best option However, there is a high DHS failure rate with unstable trochanteric femoral fractures. Hence, various fixation devices have been introduced to replace DHS in unstable fractures.These include the add-on trochanteric stabilizing plates, fixed angle blade plates, proximal femoral locked plates and different designs of cephalomedullary nails (6). Patient and method:A total of 34 patients with unstable trochanteric fractures treated surgically between June 2019 and September 2019 were included into the study and followed up for at least 6 months. Study duration: from June 2019 to February 2020.Seventeen patients underwent fixation by short gamma nail and seventeen patients underwent fixation by DHS with TSP.The mean age in DHS with TSP was 64.69 while mean age in Gamma nail group was 69.17. In DHS with TSP group there was 11 male and 6 females while in Gamma nail group there was 10 males and 7 females
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Dynamic hip screw (DHS)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Intertrochanteric
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Unstable
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Elsayed Mohamed Kassem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Aboelsoud ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Kamel Goda ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.25.M.Sc.2020.Ra.C 01010110081304000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.25.M.Sc.2020.Ra.C 01020110081304000 22.09.2023 CD - Rom 81304.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library