Conventional versus automated three-dimensional breast ultrasound in the detection and characterization of breast masses / (Record no. 77363)

MARC details
000 -LEADER
fixed length control field 02996cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032546.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200824s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.31.M.Sc.2019.Ma.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Marwa Abdellatif Elsayed Hegazy
245 10 - TITLE STATEMENT
Title Conventional versus automated three-dimensional breast ultrasound in the detection and characterization of breast masses /
Statement of responsibility, etc. Marwa Abdellatif Elsayed Hegazy ; Supervised Fatma Mohamed Awad , Sherihan Waheed Yousry Gareer , Tamer Mostafa Manie
246 15 - VARYING FORM OF TITLE
Title proper/short title مقارنة الموجات فوق الصوتية الثلاثية الابعاد الألية والموجات فوق الصوتيه التقليديه فى إيجاد وتمييز كتل الثدى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Marwa Abdellatif Elsayed Hegazy ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 101 P. :
Other physical details charts , facaimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-Diagnosis
520 ## - SUMMARY, ETC.
Summary, etc. Background: Although mammography remains the gold standard for breast imaging, it has undergone increased criticism. HHUS and mammography find significantly more early-stage breast cancers than mammography alone. However, HHUS is time consuming and has a high number of false positives. New technologies for breast cancer screening have been developed, including ABUS. Purpose: The aim of this study is to evaluate the clinical utility of automated breast ultrasound (ABUS) against handheld ultrasound (HHUS) in detecting and characterizing breast masses. Patients and methods: This study included 47 female patients of different age groups, having breast mass(es) on conventional ultrasound. HHUS and ABUS were done for all patients and evaluated by two experienced radiologists. Assessment of the breast masses was performed using BIRADS lexicon. Statistical analysis of the collected data was carried out to compare the performance of HHUS versus ABUS. Results: ABUS and HHUS showed agreement in 53 breast lesions; 4 were BIRADS II,14 lesions were BIRADS III, 9 lesions were BIRADS IV and 26 lesions were BIRADS V. One lesion was given BIRADS IVC by HHUS but BIRADS III by ABUS and histopathologically was fibroadenoma. One mass was missed by HHUS being obscured by nipple shadow, detected by ABUS as BIRADS III.Conclusion: From this study, ABUS rather than HHUS should be implemented as an adjunct to mammography for better detection and characterization of breast masses
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 2D ultrasound
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 3D automated breast ultrasound
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Digital mammography
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Fatma Mohamed Awad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sherihan Waheed Yousry Gareer ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Tamer Mostafa Manie ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.31.M.Sc.2019.Ma.C 01010110081317000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.31.M.Sc.2019.Ma.C 01020110081317000 22.09.2023 CD - Rom 81317.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library