Clinical study comparing the internal adaptation and marginal fit of all-ceramic zirconia fixed restorations obtained from conventional and digital intra oral impression techniques : (Record no. 78110)

MARC details
000 -LEADER
fixed length control field 03664cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032609.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 201006s2019 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2019.Ri.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Rivan Mahmoud Gamal Mohamed Elboghdady
245 10 - TITLE STATEMENT
Title Clinical study comparing the internal adaptation and marginal fit of all-ceramic zirconia fixed restorations obtained from conventional and digital intra oral impression techniques :
Remainder of title Randomized controlled clinical trial /
Statement of responsibility, etc. Rivan Mahmoud Gamal Mohamed Elboghdady ; Supervised Suzan Mahmoud Elsaid , Rabab Mohamed Ibrahim
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة اكلينيكية لمقارنة التكيف الداخلى و تناسب هامشية تركيبات الزركون الثابتة التى تم الحصول عليها من التقنية التقليدية وتقنية الانطباع الرقمية داخل الفم :
Remainder of title تجربه اكلينيكيه عشوائيه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Rivan Mahmoud Gamal Mohamed Elboghdady ,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent 99 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine- Department of Prosthodontic
520 ## - SUMMARY, ETC.
Summary, etc. The success of dental restorations is determined by four main factors: biocompatibility, aesthetic value, resistance to fracture and marginal adaptation. An inadequate marginal fit may compromise the longevity of the restoration since cement film exposure to the oral environment can lead to its dissolution.The consequent plaque accumulation increases the risk of secondary caries, micro leakage, endodontic inflammation and periodontal diseases causing the failure of the restoration. Marginal and internal fit can be influenced by several factors, starting from the impression phase to the final cementation process. In general dental practice impressions using elastomeric materials are a conventional procedure. These can be made with monophase or multiphase consistencies as well as one- or two-step technique. Although high quality impressions are achievable by these impression techniques and workflows, several mistakes associated with the intraoral phase or laboratory procedures may occur, leading to inaccuracies. The computer aided design/computer aided manufacturing (CAD/CAM) techniques for dental restorations have been developed to optimize the quality of the restorations as well as the efficiency of the workflow. Another target is the production of high resistance ceramic restorations which, up to date, can only be produced with these techniques. This randomized clinical study was done to compare the marginal fit and internal adaptation of the ceramic zirconia fixed restorations obtained from two impression techniques: Conventional technique dual mix two step technique and Digital Intra-oral technique. Thirty two monolithic zirconia single crowns were fabricated using in Coris TZI C zirconia blocks. The patients were selected according to eligibility criteria and divided into two groups according to the impression technique Group 1 (control group) Conventional impression technique. Group 2 (intervention group) intra-oral digital impression techniques
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CAD/CAM
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Internal adaptation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Zirconia
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Rabab Mohamed Ibrahim ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Suzan Mahmoud Elsaid ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2019.Ri.C 01010110081703000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2019.Ri.C 01020110081703000 22.09.2023 CD - Rom 81703.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library