Implantable cardiac device infections prevalence : (Record no. 78841)

MARC details
000 -LEADER
fixed length control field 03008cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032632.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 201117s2020 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.09.Ph.D.2020.He.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hend Yahia Zakaria
245 10 - TITLE STATEMENT
Title Implantable cardiac device infections prevalence :
Remainder of title Diagnostic and therapeutic implications /
Statement of responsibility, etc. Hend Yahia Zakaria ; Supervised Ashraf Wadie Andraos , Sameh Kamal Elmaraghi , Randa Ali Soliman
246 15 - VARYING FORM OF TITLE
Title proper/short title التلوث الميكروبى فى مرضى منظمات القلب الكهربية :
Remainder of title دراسة معدل الانتشار وطرق التشخيص والعلاج
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Hend Yahia Zakaria ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 126 P. :
Other physical details charts , facsmilies ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Critical Care Medicine
520 ## - SUMMARY, ETC.
Summary, etc. Background: The use of cardiac implantable electronic device (CIED) [permanent pacemakers, implantable cardioverter-defibrillators (ICD), cardiac re-synchronized therapy (CRT)], have been shown to improve mortality and quality of life in many different patient populations. Moreover, implantation rates have increased throughout the last several decades. CIED related infection is a serious complication with significant morbidity and mortality. Objectives: We sought to evaluate the prevalence of CIED related infection as well as time of onset of infection from the last device manipulation, risk factors, clinical and demographic characteristics, causative organisms and the management and outcome of patients presented in the Critical Care Department, Cairo University. Methods: A retrospective analysis was conducted of 1871 patients who had undergone cardiac device implantation with total number of devices of 1968 and 2270 procedures performed from January 2007 to December 2017. Results: Among 1871 patients we identified 59 infectious episodes with an estimated incidence of 2.99% of totally inserted devices and 2.6% of total procedures. The infection rate in patients who had undergone recurrent procedures was significantly higher than in patients a single procedure (9.27% vs. 1.18%; P<0.001). Patients with dual chamber ICD and CRTD had the highest infection rate of 6.25% & 6.85% respectively. Pocket infection was identified in 35 cases and CIED related endocarditis (CDE) was identified in 24 cases with an incidence in relation to total procedures of 1.54% & 1.06% respectively
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cardiac implantable electronic devices
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Incidence
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Infection
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ashraf Wadie Andraos ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Randa Ali Soliman ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sameh Kamal Elmaraghi ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Amira
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.09.Ph.D.2020.He.I 01010110082090000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.09.Ph.D.2020.He.I 01020110082090000 22.09.2023 CD - Rom 82090.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library