Assessment of safety, efficacy and predictability of a trifocal intra-ocular lens / (Record no. 79488)

MARC details
000 -LEADER
fixed length control field 02825cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032652.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210109s2020 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.24.Ph.D.2020.Ma.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Marian Girgis Soliman Mikhael
245 10 - TITLE STATEMENT
Title Assessment of safety, efficacy and predictability of a trifocal intra-ocular lens /
Statement of responsibility, etc. Marian Girgis Soliman Mikhael ; Supervised Mohamed Abdelmonem Hassaballa , Amr Abdellatif Osman , Sherif Ahmed Mostafa Eissa
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم أمان وفاعلية وتوقعية عدسة ثلاثية البؤرة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Marian Girgis Soliman Mikhael ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 97 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 ## - SUMMARY, ETC.
Summary, etc. AcrySof PanOptix trifocal IOL is one of the latest presbyopia correcting IOLs based on an optical technology which is different from other traditional trifocal IOLs, it is designed to help patients accomplish near and intermediate tasks with greater ease especially, at intermediate distance 60 cm not 80 cm. Our aim is to evaluate the performance of PanOptix trifocal IOL in terms of safety, efficacy, predictability and to compare contrast sensitivity, quality of vision and the aberrations induced between PanOptix trifocal IOL and Acrysof monofocol IOL. Methods :- our study is a prospective interventional non randomized study conducted on 38 eyes, 21 patients underwent phacoemulsification divided into 2 groups, group (A) implanted with PanOptix trifocal IOL,and group ( B) implanted with AcrySof monofocal IOL. Results:- PanOptix showed excellent safety, efficacy and predictability. In comparison to the monofocal group, contrast sensitivity was slightly impaired without affecting the daily activities of the patients. In addition, spectacle independence was significantly higher in the group implanted with PanOptix than the monofocal group. Conclusion :- we conclude that the success of implantation of AcrySof PanOptix IOL depends on many criteria to be fulfilled; like choosing the suitable biometry formula, thorough pre operative assessment including anterior and posterior segment examination, corneal topography, and choosing the best candidate
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term PanOptix
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Presbyopia
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Trifocal intra ocular lenses
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Abdellatif Osman ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Abdelmonem Hassaballa ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sherif Ahmed Mostafa Eissa ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.24.Ph.D.2020.Ma.A 01010110082494000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.24.Ph.D.2020.Ma.A 01020110082494000 22.09.2023 CD - Rom 82494.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library