CFD simulation and parametric analysis of airflow distribution around chillers in a mechanically ventilated room / (Record no. 79749)

MARC details
000 -LEADER
fixed length control field 02868cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032700.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210130s2020 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2020.Mo.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Rashad Mohamed Ali
245 10 - TITLE STATEMENT
Title CFD simulation and parametric analysis of airflow distribution around chillers in a mechanically ventilated room /
Statement of responsibility, etc. Mohamed Rashad Mohamed Ali ; Supervised Essam E. Khalil Hassan Khalil , Muhammed Abdullah Hassan Ahmed
246 15 - VARYING FORM OF TITLE
Title proper/short title محاكاة لتوزيع الهواء حول مُبرد الهواء المركزى داخل غرفة ميكانيكية لأداء أفضل
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Rashad Mohamed Ali ,
Date of publication, distribution, etc. 2020
300 ## - PHYSICAL DESCRIPTION
Extent 80 P. :
Other physical details charts , facimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. For cases when it is difficult to introduce sufficient amounts of natural ventilation air to air-cooled chillers, mechanical ventilation is required. A typical example is mechanical/chiller rooms. Due to the confined space, part of the chillers{u2019} exhaust air is expected to be circulated back as part of the total intake air, eventually decreasing the coefficient of performance (COP) of the chillers. The objective of this study is to simulate the airflow distribution around chillers in such mechanical-rooms and to analyze the impact of room height, locations of the intake and exhaust louvers, number of chillers, and intake air velocity on the COP of chillers. This is achieved by developing a computational fluid dynamics (CFD) model in ANSYS® 19.0. The study shows that the locations of the intake and exhaust air-louvers and the intake louver air velocity are the most influential parameters that can significantly affect the performance of the chiller, and the lower this velocity is, the higher the chiller{u2019}s intake air temperature,the best results were achieved at an intake air velocity of 2 m/s. The best configuration for the air-louvers is to introduce the air from two side inlets and to locate the exhaust louver at the top of the room. Finally, the room{u2019}s clear height also affects the recirculation process, but it has a lower impact when compared to other parameters, the best results were achieved at a mechanical-room height of 6 m.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Air cooled chiller
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Indoor Package unit
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Mechanical-room
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam E. Khalil Hassan Khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Muhammed Abdullah Hassan Ahmed ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2020.Mo.C 01010110082671000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2020.Mo.C 01020110082671000 22.09.2023 CD - Rom 82671.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library