header

Use of ⁵⁵Mn (n, Þ)⁵⁶ Mn reaction in standard neutron dosimetry / (Record no. 81671)

MARC details
000 -LEADER
fixed length control field 03382cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032801.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210814s2021 ua d f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.02.M.Sc.2021.Kh.U
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Khaled Mostafa Mohamed Mohamed
245 10 - TITLE STATEMENT
Title Use of ⁵⁵Mn (n, Þ)⁵⁶ Mn reaction in standard neutron dosimetry /
Statement of responsibility, etc. Khaled Mostafa Mohamed Mohamed ; Supervised Abdallah Abdelsalam Mohamed , Ahmed Rashad Elsersy , Waffa Osman Bahr
246 15 - VARYING FORM OF TITLE
Title proper/short title فى قياس الجرعات العيارية للنيوترون Mn⁵⁵ (n, Þ)⁵⁶Mnاستخدام تفاعل
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Khaled Mostafa Mohamed Mohamed ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 66 P. :
Other physical details charts ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics
520 ## - SUMMARY, ETC.
Summary, etc. In this thesis, a prototype Manganese bath was designed and constructed. It is composed of three parts; the 1st part is a spherical 304 stainless steel vessel with a diameter of 34 cm.The 2nd part is a hydraulic system composed of a pump for circulating the manganese (⁵⁵Mn) sulphate solution between the bath and the detection system and filter from stainless steel to prevent impurities.The 3rd part is a detection system composed of a Marinelli beaker with a 1-liter volume attached to a 3"x3" Sodium Iodide doping with Thallium (NaI (TI)) crystal detector protected in a lead shield with its electronic system.A californium (²⁵²Cf) neutron source with a flux of order 103 (n. cm⁻². s⁻¹) was used. The output dose was measured by a calibrated neutron monitor.The output flux was calculated from the flux-dose relationship. It was found that the flux delivered by the used²⁵²Cf was 170.56 ± 6.41 n. cm2. s-1 as calculated from dose measured by the neutron monitor NM2. The photopeak efficiency (f) for 56Mn atom was measured by using standard Marinelli which contains different isotopes then calculated by analytical method from linear fitting. It was found that the photopeak efficiency for 56Mn atom was 2.85 x 10⁻³ ± 1.2 x 10⁻⁴. Different concentrations of ⁵⁵Mn solution were prepared with the molarity of 0.89,1.18 and 1.48 mol/l.252Cf source was supported in the center of the bath for 24 h for each concentration.The calculated fluxes were 194.48, 186.46, and 169.79 n.cm⁻². s⁻¹ for concentration 0.89, 1.18 and 1.48 mol/l respectively. The calculated flux was improved by increasing the concentration.The uncertainty for the measured fluxes is 8.32, 7.1 and 6.67 % for concentrations 0.89,1.18 and 1.48 mol/l respectively.The uncertainty value improved with the concentration increased.The obtained data of neutron fluxes for the concentrations 1.18 and 1.48 mol/l was in good agreement with the flux measured by the calibrated neutron monitor and the certificated value of the used source
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term ⁵⁵Mn (n, Þ) ⁵⁶Mn
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CF-252
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Primary neutron dosimetry
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Abdallah Abdelsalam Mohamed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Rashad Elsersy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Waffa Osman Bahr ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.02.M.Sc.2021.Kh.U 01010110083885000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.02.M.Sc.2021.Kh.U 01020110083885000 22.09.2023 CD - Rom 83885.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library