Outcome of internal fixation of intra-articular fractures of the distal radius using polyaxial volar plate / (Record no. 83251)

MARC details
000 -LEADER
fixed length control field 03306cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032850.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211122s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.25.M.Sc.2021.Ab.O
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Abdulrahman Mahmoud Abdelghani Alafandi
245 10 - TITLE STATEMENT
Title Outcome of internal fixation of intra-articular fractures of the distal radius using polyaxial volar plate /
Statement of responsibility, etc. Abdulrahman Mahmoud Abdelghani Alafandi ; Supervised Nasser Osman Elkoussy , Ahmed Ali Afifi
246 15 - VARYING FORM OF TITLE
Title proper/short title نتائج التثبيت الداخلى لكسور أسفلعظمة الكعبرة الممتدة لسطح مفصل الرسغ بواسطة شريحة أمامية متعددة المحاور
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Abdulrahman Mahmoud Abdelghani Alafandi ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 117 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Orthopedic Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Background and aims Distal radius fractures are common injuries that have a considerable impact on health care systems.The advent of variable angle volar locking plates designed specifically for fractures of the distal radius has resulted in a major shift away from fixed angle plates, conventional plates and percutaneous fixation of these injuries. However, comparative studies have not always showed better outcomes than those less expensive techniques.Variable angle locking plates are biomechanically sound for the management of intra-articular fractures of the distal radius.They also minimize the risk of joint perforation. The primary research objective was to determine whether the use of volar distal radius variable angle locking compression plates improves functional outcome of intra-articular distal radial fractures in the short and medium term. The secondary objectives were to determine whether this plate also improves clinical and radiological measurable outcomes and the complication rate Methods A prospective case series recruiting 20 skeletally mature patients with isolated intra-articular distal radius fractures, and conducted in a tertiary care institute. Outcome assessments were conducted at 6 months post operative. The primary outcome measure was the QuickDASH score. Secondary outcomes included range of motion and grip strength measurements, modified Mayo wrist score and radiological parameter measurements. The 2.4mm distal radius variable angle locking compression plate was used Results At the end of the 6 month follow up period, the mean QuickDASH score was 15. 80% of palmar/dorsiflexion and 90% of supination/pronation ranges of the uninjured contralateral side were regained and80.5% of Grip strengthof the uninjured contralateral side was regained.Radiologically, all unions were within normal anatomical ranges.The complication rate was 25%
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Distal radius
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Intraarticular fracture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Variable angle
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Ali Afifi ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nasser Osman Elkoussy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.25.M.Sc.2021.Ab.O 01010110084805000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.25.M.Sc.2021.Ab.O 01020110084805000 22.09.2023 CD - Rom 84805.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library