header

Assessment of peri-implant tissues surrounding peek and porcelain fused to metal superstructures in posterior region : (Record no. 83733)

MARC details
000 -LEADER
fixed length control field 02918cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032905.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211227s2021 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.Ph.D.2021.Re.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Reem Mohamed Ali Gabr
245 10 - TITLE STATEMENT
Title Assessment of peri-implant tissues surrounding peek and porcelain fused to metal superstructures in posterior region :
Remainder of title A randomized controlled clinical trial /
Statement of responsibility, etc. Reem Mohamed Ali Gabr ; Supervised Hesham Alansary , Rana Sherif
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم الانسجة المحيطة بغرسات سنية ذات تركيبات فوقية مصنعة من البيك و تركيبات فوقية معدنية مغطاة بالبورسيلين في المنطقة الخلفية :
Remainder of title تجربة سريرية عشوائية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Reem Mohamed Ali Gabr ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 213 P. :
Other physical details charts , facsimiles , photoghraphs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Aim: This randomized clinical study aimed to compare the clinical performance of PEEK and PFM restorations with regard to the biological parameters, technical outcomes, and patient satisfaction.The study was conducted in participants receiving single posterior implant supported crowns Methodology : Twenty-three patients were enrolled in the study according to specific inclusion and exclusion criteria. Each patient received an implant to replace single missing tooth in posterior region. The patients were distributed among two groups.The first group (control) included (n=12) PFM implant supported crowns, the second group (comparator) included (n=11) PEEK implant supported crowns. Peri implant soft tissue parameters were evaluated using the (mPI, BOP, PD, and mGI), crestal bone loss was measured (CBL), technical complications (screw loosening, veneer chipping, fracture), implant survival, patient satisfaction (VAS), and FIPS. Results: there was no statistical significant difference between the mean of soft tissue parameters in the two groups, the mean crestal bone loss was statistically less in PEEK group the PFM. No statistical significant differences were found between the types of crows, with 100% implant survival. For the patient satisfaction regarding the crown esthetics PEEK crowns had statistically higher esthetic acceptance than PFM ones. No statistical significant differences were found for FIPS score in both groups
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term PEEK
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term PFM
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hesham Alansary ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Rana Sherif ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.Ph.D.2021.Re.A 01010110085090000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.Ph.D.2021.Re.A 01020110085090000 22.09.2023 CD - Rom 85090.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library