header
Image from OpenLibrary

Patient satisfaction, marginal adaptation and biocompatibility of milled biohpp polyetheretherketone (peek) single anterior crowns veneered with two different techniques : Randomized controlled clinical trial / By Mohamed Salah Mohamed Qasem; Supervisors Prof. Dr. Omnia Mohamed Abdel hamid El shihy, Omnia Nabil Ahmed.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 138 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • رضا المريض والتكيف الهامشي والتوافق الحيوي للتيجان الأمامية المفردة المخروطة من مادة البيو اتش بي بي بولى ايثر ايثر كيتون والمغطاة بتقنيتين مختلفتين : تجربة سريرية عشوائية [Added title page title]
Subject(s): DDC classification:
  • 617.692
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D)-Cairo University, 2024. Summary: BioHPP, a modified PEEK with 20% ceramic fillers, is highly biocompatible and non-allergic. High-quality prosthetic restorations could be produced because to BioHPP's exceptional stability, great ideal polishable characteristics, and aesthetically pleasing white tone. This clinical investigation goal was to compare milled BioHPP PEEK copings veneered with CAD/CAM composite resin to milled BioHPP PEEK copings veneered manually in order to assess patient satisfaction, marginal adaption, and biocompatibility. Thirty two PEEK crown veneered with composite (sixteen in each group) were fabricated for anterior teeth requiring full coverage restorations in esthetic zone. The patients were divided into two groups according to the type of veneering used. Group I: (control group) manual veneered crowns Group II: (intervention group) CAD/CAM veneered crowns The fabrication of the crowns was performed using CAM\CAM milling for the coppings Coping were air abraded with 110 μm Al2O3 powder at 2.5 bar and conditioned using visio.link ,the venerring was done manually for group I and the milling CAD/CAM veneer for group II the and cemented to copings using combo.lign resin cement . All teeth surfaces were dried gently for 5 seconds. Luting resin cemen1 was applied to the fitting surfaces of the crown. Patient satisfaction was evaluated according to the rating score while Marginal adaptation and Biocompatibility were evaluated according to the United States Public Health Services (USPHS) criteria. Patient satisfaction results at baseline, the mean satisfaction scores were similar between groups, with no significant difference (p=0.1536). After 6 months, scores increased in both groups, but the difference between groups remained non-significant (p=0.0660). By 1 year, scores were identical between groups (means both 1.750).Summary: ال PEEK المعدل يحتوي على 20% من حشوات السيراميك المعروفة باسم BioHPP لا تسبب الحساسية وتتمتع بقابلية حيوية عالية. تساعد إمكانية التصحيحات والثبات الممتاز وخصائص التلميع المثالية والظل الأبيض الجمالي لـ BioHPP على إنتاج ترميمات اصطناعية عالية الجودة تم إجراء هذا البحث السريري لتحقيق رضا المريض والتكيف الهامشي والتوافق الحيوي لأغطية BioHPP PEEK المطحونة والمكسوة براتنج مركب CAD/CAM ومقارنتها بأسطح BioHPP PEEK المطحونة والمكسوة بطبقات يدوية تم تصنيع اثنين وثلاثين تاجًا مكسوًا بمركب (ستة عشر في كل مجموعة) للأسنان الأمامية التي تتطلب ترميمات تغطية كاملة في المنطقة الجمالية. تم تقسيم المرضى إلى مجموعتين حسب نوع القشرة المستخدمة. المجموعة الأولى: (المجموعة الضابطة) التيجان المكسوة يدويًا المجموعة الثانية: (مجموعة التدخل) التيجان المكسوة بتقنية CAD/CAM تم تصنيع التيجان باستخدام طحن CAM\CAM للأغلفة، وتم كشطها بالهواء بمسحوق Al2O3 بقطر 110 ميكرومتر عند ضغط 2.5 بار وتم تكييفها باستخدام visio.link، وتم عمل القشرة يدويًا للمجموعة الأولى وقشرة طحن CAD/CAM لـ المجموعة الثانية وتم لصقها على الواجهات باستخدام أسمنت راتينج combo.lign. تم تجفيف كافة أسطح الأسنان بلطف لمدة 5 ثواني. تم تطبيق مادة الراتنج cemen1 على الأسطح المناسبة للتاج. تم تقييم رضا المرضى وفقًا لدرجة التصنيف بينما تم تقييم التكيف الهامشي والتوافق الحيوي وفقًا لمعايير خدمات الصحة العامة بالولايات المتحدة (USPHS). نتائج رضا المرضى عند خط الأساس، كانت درجات الرضا المتوسطة متشابهة بين المجموعات، مع عدم وجود فرق كبير (ع = 0.1536). بعد 6 أشهر، زادت الدرجات في كلا المجموعتين، ولكن الفرق بين المجموعتين بقي غير كبير (ع = 0.0660). بحلول عام واحد، كانت النتائج متطابقة بين المجموعتين (يعني 1.750). كشفت مقارنة التكيف الهامشي بين المجموعتين (مكسوة يدويًا) و(مكسوة بـ CAD/CAM) عن وجود فرق غير معنوي بين المجموعتين (ع = 1.000) (ع = 0.6738) (ع = 0.6988). عند T0، T1، T2 على التوالي. تشير القيم p غير المهمة في جميع النقاط الزمنية إلى عدم وجود فروق ذات دلالة إحصائية في توزيع درجات ألفا/برافو بين مجموعتي المراقبة والتدخل. وكانت درجات التكيف الهامشية متشابهة بين المجموعات. تشير درجات التوافق الحيوي مع مرور الوقت إلى عدم وجود فرق كبير بين مجموعات المراقبة والتدخل في أي من النقاط الزمنية. وكان توزيع الدرجات مماثلاً عند خط الأساس، وستة أشهر، وسنة واحدة. في حين أن النسبة المئوية مع النتيجة (أ) زادت قليلا من خط الأساس إلى المتابعة في كلا المجموعتين، فإن الاختلافات لم تكن ذات دلالة إحصائية.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2024.Mo.P. (Browse shelf(Opens below)) Not for loan 01010110090945000

Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)

No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.Ph.D.2023.Sa.E. The Effect Of Ips Emax Versus Vita Enamic Superstructure Materials On Implant Stability In Implant Supported Restoration : Randomized Clinical Trial / Cai01.09.09.Ph.D.2023.So.R. Retention Of 3d Printed Bases Using Prefabricated Thermoplastic Trays And Conventional Custom Impression Trays : Randomized Controlled Trial / Cai01.09.09.Ph.D.2024.Am.R. Retention of cad metallic and poly ether ether ketone (peek) frameworks in mandibular kennedy class i cases : A randomized clinical trial / Cai01.09.09.Ph.D.2024.Mo.P. Patient satisfaction, marginal adaptation and biocompatibility of milled biohpp polyetheretherketone (peek) single anterior crowns veneered with two different techniques : Randomized controlled clinical trial / Cai01.09.09.Ph.D.2024.Na.S. Shade match, marginal adaptation and patient satisfaction of vita enamic multicolor versus ips e.max cad anterior laminate veneers : Randomized clinical trial / Cai01.09.10.M.Sc.1997.Im.S Shear bond strength of resin - modified glass ionomer and a polyacid - modified composite resin to enamel and dentin / Cai01.09.10.M.Sc.2006.Da.E The effect of two different types of resin cements on the marginal integrity and bond strength of composite inlays /

Thesis (Ph.D)-Cairo University, 2024.

Bibliography: pages 128-136.

BioHPP, a modified PEEK with 20% ceramic fillers, is highly biocompatible and non-allergic. High-quality prosthetic restorations could be produced because to BioHPP's exceptional stability, great ideal polishable characteristics, and aesthetically pleasing white tone. This clinical investigation goal was to compare milled BioHPP PEEK copings veneered with CAD/CAM composite resin to milled BioHPP PEEK copings veneered manually in order to assess patient satisfaction, marginal adaption, and biocompatibility. Thirty two PEEK crown veneered with composite (sixteen in each group) were fabricated for anterior teeth requiring full coverage restorations in esthetic zone. The patients were divided into two groups according to the type of veneering used. Group I: (control group) manual veneered crowns Group II: (intervention group) CAD/CAM veneered crowns
The fabrication of the crowns was performed using CAM\CAM milling for the coppings Coping were air abraded with 110 μm Al2O3 powder at 2.5 bar and conditioned using visio.link ,the venerring was done manually for group I and the milling CAD/CAM veneer for group II the and cemented to copings using combo.lign resin cement . All teeth surfaces were dried gently for 5 seconds. Luting resin cemen1 was applied to the fitting surfaces of the crown. Patient satisfaction was evaluated according to the rating score while Marginal adaptation and Biocompatibility were evaluated according to the United States Public Health Services (USPHS) criteria. Patient satisfaction results at baseline, the mean satisfaction scores were similar between groups, with no significant difference (p=0.1536). After 6 months, scores increased in both groups, but the difference between groups remained non-significant (p=0.0660). By 1 year, scores were identical between groups (means both 1.750).

ال PEEK المعدل يحتوي على 20% من حشوات السيراميك المعروفة باسم BioHPP لا تسبب الحساسية وتتمتع بقابلية حيوية عالية. تساعد إمكانية التصحيحات والثبات الممتاز وخصائص التلميع المثالية والظل الأبيض الجمالي لـ BioHPP على إنتاج ترميمات اصطناعية عالية الجودة تم إجراء هذا البحث السريري لتحقيق رضا المريض والتكيف الهامشي والتوافق الحيوي لأغطية BioHPP PEEK المطحونة والمكسوة براتنج مركب CAD/CAM ومقارنتها بأسطح BioHPP PEEK المطحونة والمكسوة بطبقات يدوية تم تصنيع اثنين وثلاثين تاجًا مكسوًا بمركب (ستة عشر في كل مجموعة) للأسنان الأمامية التي تتطلب ترميمات تغطية كاملة في المنطقة الجمالية. تم تقسيم المرضى إلى مجموعتين حسب نوع القشرة المستخدمة. المجموعة الأولى: (المجموعة الضابطة) التيجان المكسوة يدويًا المجموعة الثانية: (مجموعة التدخل) التيجان المكسوة بتقنية CAD/CAM تم تصنيع التيجان باستخدام طحن CAM\CAM للأغلفة، وتم كشطها بالهواء بمسحوق Al2O3 بقطر 110 ميكرومتر عند ضغط 2.5 بار وتم تكييفها باستخدام visio.link، وتم عمل القشرة يدويًا للمجموعة الأولى وقشرة طحن CAD/CAM لـ المجموعة الثانية وتم لصقها على الواجهات باستخدام أسمنت راتينج combo.lign. تم تجفيف كافة أسطح الأسنان بلطف لمدة 5 ثواني. تم تطبيق مادة الراتنج cemen1 على الأسطح المناسبة للتاج. تم تقييم رضا المرضى وفقًا لدرجة التصنيف بينما تم تقييم التكيف الهامشي والتوافق الحيوي وفقًا لمعايير خدمات الصحة العامة بالولايات المتحدة (USPHS). نتائج رضا المرضى عند خط الأساس، كانت درجات الرضا المتوسطة متشابهة بين المجموعات، مع عدم وجود فرق كبير (ع = 0.1536). بعد 6 أشهر، زادت الدرجات في كلا المجموعتين، ولكن الفرق بين المجموعتين بقي غير كبير (ع = 0.0660). بحلول عام واحد، كانت النتائج متطابقة بين المجموعتين (يعني 1.750). كشفت مقارنة التكيف الهامشي بين المجموعتين (مكسوة يدويًا) و(مكسوة بـ CAD/CAM) عن وجود فرق غير معنوي بين المجموعتين (ع = 1.000) (ع = 0.6738) (ع = 0.6988). عند T0، T1، T2 على التوالي. تشير القيم p غير المهمة في جميع النقاط الزمنية إلى عدم وجود فروق ذات دلالة إحصائية في توزيع درجات ألفا/برافو بين مجموعتي المراقبة والتدخل. وكانت درجات التكيف الهامشية متشابهة بين المجموعات. تشير درجات التوافق الحيوي مع مرور الوقت إلى عدم وجود فرق كبير بين مجموعات المراقبة والتدخل في أي من النقاط الزمنية. وكان توزيع الدرجات مماثلاً عند خط الأساس، وستة أشهر، وسنة واحدة. في حين أن النسبة المئوية مع النتيجة (أ) زادت قليلا من خط الأساس إلى المتابعة في كلا المجموعتين، فإن الاختلافات لم تكن ذات دلالة إحصائية.

Issued also as CD

Text in English and abstract in English.

There are no comments on this title.

to post a comment.
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library