header
Image from OpenLibrary

Assessment Of Trueness And Internal Fit Of Glass Ceramic Crowns Constructed By Four And Five-Axis Milling Machines : An In Vitro Study / By Saba Faisal Saifan Ali; Supervisors’ Approval Prof. Dr. Carl Hany Halim, Ass. Prof. Noha Adel Elkhodary, Prof. Dr. Maha Ahmed Taymour, Prof. Dr. Marwa Mohamed Wahsh

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 97 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تقييم الثقه والتوافق الداخلى لتيجان السيراميك الزجاجيه المصنوعه بواسطة آلة الخرط رباعيه وخماسية المحاور : دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.692
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.)-Cairo University, 2024. Summary: Aim: This study aimed to assess trueness and internal fit of glass ceramic crowns (Lithium disilicate: IPS e.max CAD) constructed by four and five-axis milling machines. Methodology: A Mandibular first molar of a typodont model was prepared for full-coverage crowns. The prepared model was digitally scanned by intraoral scanner (primescan) and designed by CEREC software to fabricate 14 glass ceramic crowns (IPS e.max CAD).Group I: 4-axis ( MX CL ) and group II: 5-axis ( MCX5 ) milling machines (n =7). Then milled crowns were scanned and the internal and outer occlusal surfaces superimposed to the reference CAD model to measure the trueness by using difference analysis software (Geomagic Control X, 3D systems), while the internal gap was assessed using the silicon replica technique. Results: All areas of the crowns had higher trueness in 5- axis milling machine than the 4- axis milling machine (p < 0.05). Different crown areas had significantly different trueness values (p < 0.001, 44.07±9.78 ) in the in-lab MCX5 group and ( p < 0.001, 71.99±31.22 ) in the MC XL group. When comparing between both groups regarding internal fit, the 4-axis milling group had significantly higher internal gap than 5-axis milling group (p<0.05) for axial 2 and overall measurements. For other measurements, the difference was not statistically significant (p>0.05). Conclusions: Five-axis milling machine yielded higher trueness than the 4-axis. Four-axis milling group had significantly higher internal gap than 5-axis milling group. Summary: يعد الطحن خطوة حاسمة في إنتاج الترميمات بإستخدام أنظمة التصميم والتصنيع بمساعدة الكمبيوتر (CADCAM) أجريت هذه الدراسة لتقييم مدى الصدق والملاءمة الداخلية للتيجان الخزفية الزجاجية التي تم إنشاؤها بواسطة آلات طحن ذات أربعة محاور (تحكم) وخمسة محاور (تدخل). وفقا لحساب حجم العينة، تم إنشاء ما مجموعه أربعة عشر تاجاً من السيراميك الزجاجي (IPS e.max CAD block) والتي تم تقسيمها إلى مجموعتين متساويتين، سبع عينات لكل مجموعة وفقا لتقنية البناء. المجموعة (I): سبعة تيجان (ن=7) مصنعة بواسطة آلة طحن رباعية المحاور (تحكم). المجموعة (الثانية): سبعة تيجان (العدد=7) مصنعة بواسطة آلة طحن خماسية المحاور (تدخل). تم إعداد نموذج Typodont للرحى السفلية الأولى وفقاً للمعايير التالية: تقليل الإطباق بمقدار 2 مم، والتصغير المحوري الإجمالي بمقدار 1.5 مم، وخط النهاية المشطوف بعمق 1 مم، والتقارب الإطباق بمقدار 6 درجات. تم مسح النموذج المعد باستخدام الماسح الضوئي داخل الفم (الماسح الضوئي Primscan). ثم تم تصميم التاج التشريحي الكامل باستخدام برنامج CEREC وتم إنتاجه من كتل e.max CAD بواسطة آلات الطحن MCXL (4 محاور) وMCX5 (5 محاور). أظهرت النتائج أن جميع مناطق التيجان كانت لها دقة أعلى في آلة الطحن ذات 5 محاور مقارنة بآلة الطحن ذات 4 محاور. عند المقارنة بين المجموعتين فيما يتعلق بالملاءمة الداخلية، كان لمجموعة الطحن ذات 4 محاور فجوة داخلية أعلى بكثير من مجموعة الطحن ذات 5 محاور.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2024.Sa.A. (Browse shelf(Opens below)) Not for loan 01010110090640000

Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)

No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.M.Sc.2024.Ra.E. Effect of er, cr:ysgg laser surface treatment on microshear bond strength of monolithic extra translucent zirconia to resin cement : An in-vitro study / Cai01.09.09.M.Sc.2024.Ra.P Prevalence of tempromandibular joint disorders among egyptian university undergraduate students : a cross-sectional study / Cai01.09.09.M.Sc.2024.Ri.P Peri-implant stress distribution in maxillary "All-on-4" prostheses fabricated on multi-unit angled abutments with cobalt chromium framework versus those with polyether ketone (PEEK) framework : A 3D Finite Element Analysis / Cai01.09.09.M.Sc.2024.Sa.A. Assessment Of Trueness And Internal Fit Of Glass Ceramic Crowns Constructed By Four And Five-Axis Milling Machines : An In Vitro Study / Cai01.09.09.M.Sc.2024.So.E. Effect of two different sintering protocols on translucency of monolithic translucent zirconia : An invitro study / Cai01.09.09.M.Sc.2024.So.E Evaluation of marginal adaptation of two glass ceramic occlusal veneers under thermocycling : an in vitro study Cai01.09.09.M.Sc.2024.Ya.A Assessment of translucency and color stability of pressed versus milled zirconia- reinforced lithium silicate glass ceramics : an in vitro study /

Thesis (M.Sc.)-Cairo University, 2024.

Bibliography: pages 88-95.

Aim: This study aimed to assess trueness and internal fit of glass ceramic crowns (Lithium disilicate: IPS e.max CAD) constructed by four and five-axis milling machines.
Methodology: A Mandibular first molar of a typodont model was prepared for full-coverage crowns. The prepared model was digitally scanned by intraoral scanner (primescan) and designed by CEREC software to fabricate 14 glass ceramic crowns (IPS e.max CAD).Group I: 4-axis ( MX CL ) and group II: 5-axis ( MCX5 ) milling machines (n =7). Then milled crowns were scanned and the internal and outer occlusal surfaces superimposed to the reference CAD model to measure the trueness by using difference analysis software (Geomagic Control X, 3D systems), while the internal gap was assessed using the silicon replica technique.
Results: All areas of the crowns had higher trueness in 5- axis milling machine than the 4- axis milling machine (p < 0.05). Different crown areas had significantly different trueness values (p < 0.001, 44.07±9.78 ) in the in-lab MCX5 group and ( p < 0.001, 71.99±31.22 ) in the MC XL group. When comparing between both groups regarding internal fit, the 4-axis milling group had significantly higher internal gap than 5-axis milling group (p<0.05) for axial 2 and overall measurements. For other measurements, the difference was not statistically significant (p>0.05).
Conclusions: Five-axis milling machine yielded higher trueness than the 4-axis. Four-axis milling group had significantly higher internal gap than 5-axis milling group.

يعد الطحن خطوة حاسمة في إنتاج الترميمات بإستخدام أنظمة التصميم والتصنيع بمساعدة الكمبيوتر (CADCAM) أجريت هذه الدراسة لتقييم مدى الصدق والملاءمة الداخلية للتيجان الخزفية الزجاجية التي تم إنشاؤها بواسطة آلات طحن ذات أربعة محاور (تحكم) وخمسة محاور (تدخل).
وفقا لحساب حجم العينة، تم إنشاء ما مجموعه أربعة عشر تاجاً من السيراميك الزجاجي (IPS e.max CAD block) والتي تم تقسيمها إلى مجموعتين متساويتين، سبع عينات لكل مجموعة وفقا لتقنية البناء.
المجموعة (I): سبعة تيجان (ن=7) مصنعة بواسطة آلة طحن رباعية المحاور (تحكم).
المجموعة (الثانية): سبعة تيجان (العدد=7) مصنعة بواسطة آلة طحن خماسية المحاور (تدخل).
تم إعداد نموذج Typodont للرحى السفلية الأولى وفقاً للمعايير التالية: تقليل الإطباق بمقدار 2 مم، والتصغير المحوري الإجمالي بمقدار 1.5 مم، وخط النهاية المشطوف بعمق 1 مم، والتقارب الإطباق بمقدار 6 درجات. تم مسح النموذج المعد باستخدام الماسح الضوئي داخل الفم (الماسح الضوئي Primscan). ثم تم تصميم التاج التشريحي الكامل باستخدام برنامج CEREC وتم إنتاجه من كتل e.max CAD بواسطة آلات الطحن MCXL (4 محاور) وMCX5 (5 محاور).
أظهرت النتائج أن جميع مناطق التيجان كانت لها دقة أعلى في آلة الطحن ذات 5 محاور مقارنة بآلة الطحن ذات 4 محاور. عند المقارنة بين المجموعتين فيما يتعلق بالملاءمة الداخلية، كان لمجموعة الطحن ذات 4 محاور فجوة داخلية أعلى بكثير من مجموعة الطحن ذات 5 محاور.

Issued also as CD

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library