Validity and Reliability of Modified Sphygmomanometer versus Jamar Dynamometer in Measuring Hand Grip Strength for Patients with Distal Radius Fractures / By Eman Hesham Anwar Rashwan; Under Supervision of Prof. Salwa Fadl Abd El Majeed, Dr. Mohamed Ezzat Mohamed, Dr. Emad Ahmed Abdel Ati

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 74 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • صلاحية وموثوقية مقياس ضغط الدم المعدل مقابل الجامر دينامومتر في قياس قوة قبضة اليد لمرضي كسور مفصل الرسغ [Added title page title]
Subject(s): DDC classification:
  • 615.82
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.)-Cairo University, 2024. Summary: Background: The modified sphygmomanometer and Jamar grip dynamometer are important instruments to measure the hand grip strength (HGS). Purposes: This study was conducted to test the concurrent validity, test–retest and interrater reliability of bag modified sphygmomanometer and Jamar grip dynamometer. Subjects and Methods: Seventy patients of distal radius fracture (67 colles’ and 3 smith fracture) with mean age 45.03 ± 10.45 years, were recruited to evaluate the grip strength by Jamar grip dynamometer and bag modified sphygmomanometer after modifying the (KBM) sphygmomanometer in a bag and calibrated in box of plates. Validity was explained by the correlation between hand grip strength that was assessed by modified sphygmomanometer and Jamar dynamometer by Person Correlation Coefficient. Test–retest reliability and inter–rater reliability was expressed as Intra–class Correlation Coefficients (ICCs). All data was analyzed by (SPSS) version 25 for windows. Results: There were correlations between hand grip strength that was assessed by modified sphygmomanometer and Jamar dynamometer in the study group was strong positive significant correlation in concurrent validity (r = 0.852, p = 0.001), The modified sphygmomanometer showed excellent in test–retest reliability with Intraclass correlation coefficient (ICC) was 0.996 and in interrater reliability with 0.993 Intraclass correlation coefficient. Conclusion: The bag modified sphygmomanometer is a concurrently valid, test–retest and interrater reliable instruments for measuring hand grip of distal radius fracture patients with different gender and fixation types.Summary: تم ضم سبعين مريضا بمتوسط عمر45.03 ± 10.45 عاما لتقييم قوة قبضة اليد بمقياس الجامر دينامومتر وحقيبة مقياس ضغط الدم المعدل وتم معايرته في علبة مع طارات وزن وتم اختبار هدف الدراسة من حيث الصلاحية بمعامل ارتباط بيرسون ومن حيث الموثوقية الاختبار وإعادة الاختبار وثبات النتائج مع تغيير المقيمين بمعاملات الارتباط داخل الطبقة.(ICCs) وقد تم تحليل جميع البيانات بواسطة برنامج (SPSS) الإصدار 25 لنظام التشغيل. حقيبة جهاز ضغط الدم المعدل تمتلك صلاحية متزامنة وموثوقية الاختبار وإعادة الاختبار وموثوقية ثبات النتائج مع تغيير المقيمين لقياس قوة قبضة اليد لمرضى كسور مفصل الرسغ مع اختلاف أنواع الثبيت ونوع المريض.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.21.03.M.Sc.2024.Em.V. (Browse shelf(Opens below)) Not for loan 01010110091113000

Thesis (M.Sc.)-Cairo University, 2024.

Bibliography: pages 66-73.

Background: The modified sphygmomanometer and Jamar grip
dynamometer are important instruments to measure the hand grip strength
(HGS). Purposes: This study was conducted to test the concurrent
validity, test–retest and interrater reliability of bag modified
sphygmomanometer and Jamar grip dynamometer. Subjects and
Methods: Seventy patients of distal radius fracture (67 colles’ and 3 smith
fracture) with mean age 45.03 ± 10.45 years, were recruited to evaluate
the grip strength by Jamar grip dynamometer and bag modified
sphygmomanometer after modifying the (KBM) sphygmomanometer in a
bag and calibrated in box of plates. Validity was explained by the
correlation between hand grip strength that was assessed by modified
sphygmomanometer and Jamar dynamometer by Person Correlation
Coefficient. Test–retest reliability and inter–rater reliability was expressed
as Intra–class Correlation Coefficients (ICCs). All data was analyzed by
(SPSS) version 25 for windows. Results: There were correlations between
hand grip strength that was assessed by modified sphygmomanometer and
Jamar dynamometer in the study group was strong positive significant
correlation in concurrent validity (r = 0.852, p = 0.001), The modified
sphygmomanometer showed excellent in test–retest reliability with
Intraclass correlation coefficient (ICC) was 0.996 and in interrater
reliability with 0.993 Intraclass correlation coefficient. Conclusion: The
bag modified sphygmomanometer is a concurrently valid, test–retest and
interrater reliable instruments for measuring hand grip of distal radius
fracture patients with different gender and fixation types.

تم ضم سبعين مريضا بمتوسط عمر45.03 ± 10.45 عاما لتقييم قوة قبضة اليد بمقياس الجامر دينامومتر وحقيبة مقياس ضغط الدم المعدل وتم معايرته في علبة مع طارات وزن وتم اختبار هدف الدراسة من حيث الصلاحية بمعامل ارتباط بيرسون ومن حيث الموثوقية الاختبار وإعادة الاختبار وثبات النتائج مع تغيير المقيمين بمعاملات الارتباط داخل الطبقة.(ICCs) وقد تم تحليل جميع البيانات بواسطة برنامج (SPSS) الإصدار 25 لنظام التشغيل. حقيبة جهاز ضغط الدم المعدل تمتلك صلاحية متزامنة وموثوقية الاختبار وإعادة الاختبار وموثوقية ثبات النتائج مع تغيير المقيمين لقياس قوة قبضة اليد لمرضى كسور مفصل الرسغ مع اختلاف أنواع الثبيت ونوع المريض.

Issued also as CD

Text in English and abstract in Arabic & English.