Accuracy of cad/cam cutting guides and customized titanium plates for virtual planning transfer compared to classic model surgery in bimaxillary orthognathic surgeries : a randomized controlled clinical trial / by Mohamed Ali Zain El-Abden Abd El-Wahab ; Supervisors Prof. Maha Mohamed Hakam, Dr. Adel Hamdy Abou-ElFetouh, Dr. Mahmoud Hanafy Mahmoud.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 147 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • دقة أدلة القطع وشرائح التيتانيوم المخصصة للمريض لنقل التخطيط الافتراضي ومقارنتها بالنموذج الجراحي التقليدي في جراحات تقويم الفكين : تجربة سريرية بالإنتقاء العشوائي [Added title page title]
Subject(s): DDC classification:
  • 617.605
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (Ph.D)-Cairo University, 2024. Summary: Aim of the study: To evaluate the accuracy of CAD/CAM cutting guides and customized titanium plates in transferring the virtual plan in comparison to classic model surgery approach in bimaxillary orthognathic surgeries. Methods: A total of 18 patients indicated for bi-maxillary orthognathic surgery randomly assigned to 2 equal parallel groups; 9 patients were treated by CAD/CAM cutting guides and customized titanium plates (group 1) (intervention group) and 9 patients treated using classic model surgery (group 2) (control group). Accuracy of transfer and patient satisfaction were assessed for each group. Results: Both groups showed significant deviation in accuracy from the virtual plan. However, maxillary mediolateral linear deviation in group 1 showed statistically significant lower values (more accurate) than that in group 2. While mandibular vertical and anteroposterior linear deviation in group 1 showed statistically significant values (more accurate) than that in group 2. While for other planes and measurements, the difference in accuracy between the two groups was not statistically significant (p>0.05). The maxillary linear deviation didn’t exceed 1.37 mm in group 1, while in group 2 was up to 1.78 mm, and the maximum mandibular linear deviation in group 1 was 1.55 mm, while in group 2 was 1.61 mm. Conclusion: Computer-guided orthognathic surgery workflow provide more accuracy than classic model surgery. However both groups showed significant deviation from the virtual plan. Minor inaccuracies occurred in both groups did not affect the clinical outcome and patient quality of life in the included sample.Summary: • إن هدف هذه الدراسة هو تقييم دقة الجراحة التقويمية للفكين بمساعدة الحاسوب ومقارنتها بالنموذج الجراحي التقليدي لمرضى التشوهات السنية الفكية. • اشتملت الدراسة على ۱۸ مريض (۷ ذكور و۱۱ اناث) بمتوسط اعمار ۲۲.۵ (تتراوح من ۱۸ إلى ۲۷) يعانون من تشوهات سنية فكية تستلزم إجراء جراحة تقويمية للفكين. • خضع جميع المرضى للتجهيزات الجراحية ثلاثية الأبعاد ثم لمحاكاة جراحية افتراضية بمساعدة الحاسوب. ثم تم تقسيم المرضى عشوائيا إلى مجموعتين احتوت كل مجموعة على ۹ مرضى, حيث خضعت المجموعة الأولى (مجموعة الدراسة) إلى جراحة تقويمية للفكين بمساعدة الحاسوب, بينما استخدم النموذج الجراحي التقليدي في المجموعة الثانية (مجموعة المراقبة). • خضع جميع المرضى لنموذج استطلاع جودة الحياة لجراحات تقويم الفكين قبل الجراحة وبعدها بستة أشهر وتم تقييم المرضى سريريا وبالأشعة المقطعية ذات الشعاع المخروطي الشكل قبل الجراحة وبعدها بأسبوع على الأكثر وخضع المسح الإشعاعي إلى قياسات خطية للنقاط المرجعية في أبعاد الفراغ الثلاثة وتم مقارنة قراءات المجموعتين. • وصلت دقة الجراحة بالفك العلوي بمساعدة الحاسوب إلى متوسط انحراف عن الخطة الجراحية مقداره 0.81 مم رأسيا, 1.27 مم للأمام أو الخلف, 0.38 مم لليمين أو اليسار, بينما وصل متوسط انحراف النموذج التقليدي عن الخطة الجراحية للفك العلوي حتى 0.98 مم رأسيا, 1.62 مم للأمام أو الخلف, 0.69 مم لليمين أو اليسار. بينما وصلت دقة الجراحة بالفك السفلي بمساعدة الحاسوب إلى متوسط انحراف عن الخطة الجراحية مقداره 0.85 مم رأسيا, 1.13 مم للأمام أو الخلف, 0.52 مم لليمين أو اليسار, أما متوسط انحراف النموذج التقليدي عن الخطة الجراحية للفك السفلي فقد وصل حتى 1.21 مم رأسيا, 1.51 مم للأمام أو الخلف, 0.64 مم لليمين أو اليسار. في حين لم تظهر استطلاعات جودة الحياة اختلافا ذا دلالة إحصائية بين المجموعتين. • من خلال هذه الدراسة نستنتج: أ‌- تستطيع الجراحة التقويمية الموجهة بالحاسوب بالنموذج المقدم في هذه الدراسة الوصول إلى مستوى عال من الدقة. ب‌- هذه الدقة العالية تدعم استخدام هذه التقنية بشكل يومي لاسيما في المؤسسات ذات الطابع التدريبي. ت‌- أكبر العيوب الحالية في النموذج المقدم في هذه الدراسة يتمثل في التكلفة والوقت المستهلك لتحويل النموذج ثلاثي الأبعاد إلى نموذج يصلح للتصميم بمساعدة الحاسوب, ونظراً للمعدل الذي تتقدم به هذه التقنيات فمن المتوقع أن يقل الوقت والتكلفة حتى توازي نظيرتها في النموذج الجراحي التقليدي.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2024.Mo.A (Browse shelf(Opens below)) Not for loan 01010110091370000

Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)

No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.13.M.Sc.2024.Hu.E. Evaluation Of Minimally Invasive Alveolar Augmentation Procedure Of Anterior Maxillary Ridge Using Tunneling Surgical Technique / Cai01.09.13.M.Sc.2024.Mo.A Assessment of horizontal ridge augmentation in anterior mandible using computer guided autogenous cortical shell technique versus free hand technique : randomized clinical trial / Cai01.09.13.M.Sc.2024.Mo.A. Assessment of esthetic integration of patient specific peek dental implant versus conventional titanium implant for immediate tooth replacement in esthetic maxillary zone : Randomized clinical study / Cai01.09.13.M.Sc.2024.Mo.A Accuracy of cad/cam cutting guides and customized titanium plates for virtual planning transfer compared to classic model surgery in bimaxillary orthognathic surgeries : a randomized controlled clinical trial / Cai01.09.13.M.Sc.2024.Mo.E Efficiency of using osseodensification protocol for alveolar ridge expansion in casess of atrophic edentulous alveolar ridges RCT : randomized controlled trial / Cai01.09.13.M.Sc.2024.Mo.P Patient specific 3D printed titanium mesh versus computer guided calvarial bone graft for orbital floor reconstruction : A randomized clinical trial / Cai01.09.13.M.Sc.2024.Om.S. Simultaneous Implant Placement With Autogenous Bone Ring Transplant Vs. Autogenous Sticky Bone Graft In Maxillary Sinus Lifting : Randomization Clinical Trial /

Thesis (Ph.D)-Cairo University, 2024.

Bibliography: pages 132-144.

Aim of the study: To evaluate the accuracy of CAD/CAM cutting guides and customized titanium plates in transferring the virtual plan in comparison to classic model surgery approach in bimaxillary orthognathic surgeries.
Methods: A total of 18 patients indicated for bi-maxillary orthognathic surgery randomly assigned to 2 equal parallel groups; 9 patients were treated by CAD/CAM cutting guides and customized titanium plates (group 1) (intervention group) and 9 patients treated using classic model surgery (group 2) (control group). Accuracy of transfer and patient satisfaction were assessed for each group.
Results: Both groups showed significant deviation in accuracy from the virtual plan. However, maxillary mediolateral linear deviation in group 1 showed statistically significant lower values (more accurate) than that in group 2. While mandibular vertical and anteroposterior linear deviation in group 1 showed statistically significant values (more accurate) than that in group 2. While for other planes and measurements, the difference in accuracy between the two groups was not statistically significant (p>0.05). The maxillary linear deviation didn’t exceed 1.37 mm in group 1, while in group 2 was up to 1.78 mm, and the maximum mandibular linear deviation in group 1 was 1.55 mm, while in group 2 was 1.61 mm.
Conclusion: Computer-guided orthognathic surgery workflow provide more accuracy than classic model surgery. However both groups showed significant deviation from the virtual plan. Minor inaccuracies occurred in both groups did not affect the clinical outcome and patient quality of life in the included sample.

• إن هدف هذه الدراسة هو تقييم دقة الجراحة التقويمية للفكين بمساعدة الحاسوب ومقارنتها بالنموذج الجراحي التقليدي لمرضى التشوهات السنية الفكية.
• اشتملت الدراسة على ۱۸ مريض (۷ ذكور و۱۱ اناث) بمتوسط اعمار ۲۲.۵ (تتراوح من ۱۸ إلى ۲۷) يعانون من تشوهات سنية فكية تستلزم إجراء جراحة تقويمية للفكين.
• خضع جميع المرضى للتجهيزات الجراحية ثلاثية الأبعاد ثم لمحاكاة جراحية افتراضية بمساعدة الحاسوب. ثم تم تقسيم المرضى عشوائيا إلى مجموعتين احتوت كل مجموعة على ۹ مرضى, حيث خضعت المجموعة الأولى (مجموعة الدراسة) إلى جراحة تقويمية للفكين بمساعدة الحاسوب, بينما استخدم النموذج الجراحي التقليدي في المجموعة الثانية (مجموعة المراقبة).
• خضع جميع المرضى لنموذج استطلاع جودة الحياة لجراحات تقويم الفكين قبل الجراحة وبعدها بستة أشهر وتم تقييم المرضى سريريا وبالأشعة المقطعية ذات الشعاع المخروطي الشكل قبل الجراحة وبعدها بأسبوع على الأكثر وخضع المسح الإشعاعي إلى قياسات خطية للنقاط المرجعية في أبعاد الفراغ الثلاثة وتم مقارنة قراءات المجموعتين.
• وصلت دقة الجراحة بالفك العلوي بمساعدة الحاسوب إلى متوسط انحراف عن الخطة الجراحية مقداره 0.81 مم رأسيا, 1.27 مم للأمام أو الخلف, 0.38 مم لليمين أو اليسار, بينما وصل متوسط انحراف النموذج التقليدي عن الخطة الجراحية للفك العلوي حتى 0.98 مم رأسيا, 1.62 مم للأمام أو الخلف, 0.69 مم لليمين أو اليسار. بينما وصلت دقة الجراحة بالفك السفلي بمساعدة الحاسوب إلى متوسط انحراف عن الخطة الجراحية مقداره 0.85 مم رأسيا, 1.13 مم للأمام أو الخلف, 0.52 مم لليمين أو اليسار, أما متوسط انحراف النموذج التقليدي عن الخطة الجراحية للفك السفلي فقد وصل حتى 1.21 مم رأسيا, 1.51 مم للأمام أو الخلف, 0.64 مم لليمين أو اليسار. في حين لم تظهر استطلاعات جودة الحياة اختلافا ذا دلالة إحصائية بين المجموعتين.
• من خلال هذه الدراسة نستنتج:
أ‌- تستطيع الجراحة التقويمية الموجهة بالحاسوب بالنموذج المقدم في هذه الدراسة الوصول إلى مستوى عال من الدقة.
ب‌- هذه الدقة العالية تدعم استخدام هذه التقنية بشكل يومي لاسيما في المؤسسات ذات الطابع التدريبي.
ت‌- أكبر العيوب الحالية في النموذج المقدم في هذه الدراسة يتمثل في التكلفة والوقت المستهلك لتحويل النموذج ثلاثي الأبعاد إلى نموذج يصلح للتصميم بمساعدة الحاسوب, ونظراً للمعدل الذي تتقدم به هذه التقنيات فمن المتوقع أن يقل الوقت والتكلفة حتى توازي نظيرتها في النموذج الجراحي التقليدي.