Seismic behavior of R.C. structures with floating columns / by Moamen Elsayed Mohamed Ahmed Elhattab ; Supervisors Prof.Dr. Hany Ahmed Abdalla.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2025Description: 140 pages : illustrations ; 30 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • السلوك الزلزالي للمنشآت الخرسانية ذات الأعمدة العائمة [Added title page title]
Subject(s): DDC classification:
  • 624.1
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2025. Summary: This research investigates the seismic behavior of reinforced concrete structures with floating columns, Floating columns discontinued vertical load paths result in a poorer structure’s seismic behavior compared to one using ordinary Columns and increase the chance of encountering soft storey at the transfer floor. In this research using ETABS Software, 18 cases of G+10 structures with different floating column layouts, different end conditions with transfer beams, and different shear wall cases were investigated. The study monitored four structural aspects: Storey displacements, Inter-Storey Drift, Storey Stiffness, and Storey Shear Force. Results showed that narrowing the spans between floating columns, using fixed connection between floating columns and transfer beams, and using shear walls has greatly enhanced the floating column’s structure seismic behavior and reduce the chances of forming soft-storeySummary: يتناول هذا البحث دراسة السلوك الزلزالي للمباني الخرسانية الهيكلية ذات الأعمدة العائمة نظرا لكثره استخدام النظام في المباني الحديثة. تنقل الأعمدة العادية الأحمال الرأسية مباشره الي الأساسات بينما تنقل الأعمدة العائمة الأحمال بصوره غير مباشره عن طريق عنصر أفقي مثل الكمرات الناقلة للأحمال. ينتج عن ذلك سلوك زلزالي أقل كفائه مقارنه بالمباني العادية مع زيادة احتماليه تكون طابق لين في الطوابق المجاورة للطابق الانتقالي. تمت الدراسة باستخدام برنامج ETABS على 18 حاله مختلفة لمنشأ خرساني مكون من 11 طابقا تختلف فيها الأبعاد بين الأعمدة العائمة ونوع الأتصال بين الأعمدة العائمة وبين الكمرات الناقلة و وجود حوائط مسلحة في المنشأ. ركزت الدراسة على أربع نتائج رئيسية وهي الإزاحات بين الطوابق، الإنحياد بين الطوابق، جساءة الطوابق، وقوى القص في الطوابق. وقد أظهرت النتائج ان التقارب بين الأعمدة العائمة مع استخدام وصلات تمنع الدوران بينها وبين الكمرة الناقلة مع وجود حوائط قص الي تحسن كبير في الأداء الزلزالي مع تقليل احتمالية تكون طابق لين.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)

Thesis (M.Sc)-Cairo University, 2025.

Bibliography: pages 126-125.

This research investigates the seismic behavior of reinforced concrete structures with floating columns, Floating columns discontinued vertical load paths result in a poorer structure’s seismic behavior compared to one using ordinary Columns and increase the chance of encountering soft storey at the transfer floor.
In this research using ETABS Software, 18 cases of G+10 structures with different floating column layouts, different end conditions with transfer beams, and different shear wall cases were investigated. The study monitored four structural aspects: Storey displacements, Inter-Storey Drift, Storey Stiffness, and Storey Shear Force.
Results showed that narrowing the spans between floating columns, using fixed connection between floating columns and transfer beams, and using shear walls has greatly enhanced the floating column’s structure seismic behavior and reduce the chances of forming soft-storey

يتناول هذا البحث دراسة السلوك الزلزالي للمباني الخرسانية الهيكلية ذات الأعمدة العائمة نظرا لكثره استخدام النظام في المباني الحديثة. تنقل الأعمدة العادية الأحمال الرأسية مباشره الي الأساسات بينما تنقل الأعمدة العائمة الأحمال بصوره غير مباشره عن طريق عنصر أفقي مثل الكمرات الناقلة للأحمال. ينتج عن ذلك سلوك زلزالي أقل كفائه مقارنه بالمباني العادية مع زيادة احتماليه تكون طابق لين في الطوابق المجاورة للطابق الانتقالي. تمت الدراسة باستخدام برنامج ETABS على 18 حاله مختلفة لمنشأ خرساني مكون من 11 طابقا تختلف فيها الأبعاد بين الأعمدة العائمة ونوع الأتصال بين الأعمدة العائمة وبين الكمرات الناقلة و وجود حوائط مسلحة في المنشأ. ركزت الدراسة على أربع نتائج رئيسية وهي الإزاحات بين الطوابق، الإنحياد بين الطوابق، جساءة الطوابق، وقوى القص في الطوابق. وقد أظهرت النتائج ان التقارب بين الأعمدة العائمة مع استخدام وصلات تمنع الدوران بينها وبين الكمرة الناقلة مع وجود حوائط قص الي تحسن كبير في الأداء الزلزالي مع تقليل احتمالية تكون طابق لين.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library