The effect on stability Using Max VPC screw vs. lag screw in the treatment of mandibular symphysis fracture : A pilot study / by Sherif Hany Shams El Din ; Supervisors Dr. Mohamed Galal Beheiri, Dr. Mohamed Khashaba.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2021Description: 80 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • التاثير علي التثبيت باستخدام مسمار(ماكس في بي سي)بالمقارنة مع مسمار (لاج سكرو) في علاج كسور الذقن : دراسة أولية [Added title page title]
Subject(s): DDC classification:
  • 617.605
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (Ph.D)-Cairo University, 2021. Summary: stability after osteosynthesis with MAX VPC screw Methodology: 10 patients with symphyseal fractures were included in this study, they were divided on 2 groups of 5, the patients were assessed by Multislice CT scans. Study group received treatment with 2 Max Vpc screws, the control group received treatment with 2 lag screws. The outcomes that were studied were hardware installation time,stability of occlusion, interfragmentary stability, and pain. Results: The study was conducted on 10 patients, all cases went uneventful, the only significant difference was found in the hardware installation time favoring the study group. In all the other parameters (stability of occlusion, interfragmentary stability, and pain) no statistical difference was recorded. Conclusions: Treatment of symphyseal mandibular fractures with Max Vpc headless compression screws is a valid treatment modality that is comparable to other treatment modalities and presented a faster method of treatment.Summary: الغرض من هذه الرسالة هو دراسة التاثير علي التثبيت باستخدام مسمار(ماكس في بي سي)بالمقارنة مع مسمار (لاج سكرو) في علاج كسور الذقن. (دراسة أولية) . وقد تم اختيار 10 مريضا يعانون من كسور الذقن بعد أخذ الموافقة الشفهية للاشتراك في هذه الرسالة من كل مريض، تم شرح الخطوات العلاجية وأخذ التاريخ المرضي واجراء القياسات اللازمة تم علاج المرضي عن طريق وضع وضع مسمارين لتثبيت الكسر
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.Ph.D.2021.Sh.E (Browse shelf(Opens below)) Not for loan 01010110092095000

Thesis (Ph.D)-Cairo University, 2021.

Bibliography: pages 75-79.

stability after osteosynthesis with MAX VPC screw
Methodology: 10 patients with symphyseal fractures were included in this study, they were divided on 2 groups of 5, the patients were assessed by Multislice CT scans. Study group received treatment with 2 Max Vpc screws, the control group received treatment with 2 lag screws. The outcomes that were studied were hardware installation time,stability of occlusion, interfragmentary stability, and pain.
Results: The study was conducted on 10 patients, all cases went uneventful, the only significant difference was found in the hardware installation time favoring the study group.
In all the other parameters (stability of occlusion, interfragmentary stability, and pain) no statistical difference was recorded.
Conclusions: Treatment of symphyseal mandibular fractures with Max Vpc headless compression screws is a valid treatment modality that is comparable to other treatment modalities and presented a faster method of treatment.

الغرض من هذه الرسالة هو دراسة التاثير علي التثبيت باستخدام مسمار(ماكس في بي سي)بالمقارنة مع مسمار (لاج سكرو) في علاج كسور الذقن. (دراسة أولية)
. وقد تم اختيار 10 مريضا يعانون من كسور الذقن
بعد أخذ الموافقة الشفهية للاشتراك في هذه الرسالة من كل مريض، تم شرح الخطوات العلاجية وأخذ التاريخ المرضي واجراء القياسات اللازمة
تم علاج المرضي عن طريق وضع وضع مسمارين لتثبيت الكسر

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library