Accuracy of implant placement using a fully guided surgical guide designed using blenderfordental versus exoplan softwares : an in vitro study / by John Elia Farag Allah AbdelNoor ; Supervisors Prof. Nadia Ahmed Abbas, Prof. Mohamed Amr El khashab.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2025Description: 84 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • دقة وضع الغرسات باستخدام دليل جراحي موجه بالكامل مصمم بواسطة برنامج بلندر فور دينتال مقارنةً برنامج الاكذوبلان : دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.69
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2025. Summary: Aim: The aim of this in vitro study was to compare the accuracy of implant placement when using tooth supported surgical guide using a fully guided surgical guide design performed on different softwares of them are non-dental software (Blenderfordental) versus a dental software (Exoplan). Methodology: Twenty study models, simulating patients with a missing upper left first molar, were divided into two groups: Group I (Exoplan) and Group II (Blender). Each group underwent digital implant planning and surgical guide fabrication using their respective software. A typodont model was digitally scanned and segmented to create a virtual model. This model was further processed to serve as the basis for implant planning. DICOM data from a CBCT scan of a physical model were integrated into the planning software to enhance accuracy. Implant planning was performed using a top-down approach, considering prosthetic requirements and selecting an appropriate implant from the software's library. Surgical guides were designed and fabricated using the software's features, ensuring accurate implant placement and minimizing surgical invasiveness. After implant placement, scanbodies were attached to the implants, and postoperative scans were acquired. By superimposing the preoperative and postoperative scans, deviations in implant position were measured along the buccolingual, mesiodistal, and apico-coronal axes. Results: Normality tests (Shapiro-Wilk and Kolmogorov-Smirnov) confirmed the normal distribution of quantitative data (p > 0.05). No statistically significant differences were found between the two groups for buccolingual (p = 0.83), mesiodistal (p = 0.41), and depth (p = 0.75) dimensions. Mean values for buccolingual, mesiodistal, and depth measurements were comparable between groups. Conclusion: Open-source software designed for non-dental applications, such as Blender, can be utilized to create dental implant surgical guides with accuracy that is not significantly different from commercially available dental implant treatment planning software like Exoplan. Both Exoplan and Blender groups demonstrated statistically not significant deviations from the ideal implant position along all three axes. These findings suggest that open-source software can be used for dental implant surgical guide fabrication.Summary: أجريت هذه الدراسة للمقارنة بين دقة برنامج ) Blender ( الذي تم تطويره من قبل المنظمات المهنية غير المتخصصة في طب الأسنان و Exoplan لاختبار دقة المكتبات المضمنة ودقتها وقدرة أدواتها على جمع البيانات. بشكل صحيح لتكون ودودًا في استخدام الأسنان باستخدام أدلة جراحية مدعومة بالأسنان بالكامل في هذه الدراسة باستخدام تصميمات مسبقة الطباعة لتلائم هذا البحث وموحدة من خلال الدراسة بأكملها ، تم تصميم القالب باستخدام ضرس واحد مفقود وتم تحضيره كقالب مرجعي ، ثم تم تشميع الأسنان المفقودة ثم تم مسح نماذج الدراسة بشكل فردي باستخدام ماسح ضوئي خارج الفم. ثم تم إنشاء ملفات DICOM للمرجعية عن طريق مسح CBCT ، تم إجراء تخطيطين مختلفين للغرس باستخدام برنامج طب الأسنان ) Exoplan ( وبرنامج CAD غير خاص بالأسنان ) Blender ( ، كل منها يتضمن تخطيط الغرس ، ووضع الغرسة الافتراضية وتصنيع دليل جراحي مدعوم بالأسنان على أسنان متجاورة باستخدام نفس سير العمل العام لكل برنامج باستخدام تصميم دليل معياري ومتغيرات إنتاج توجيهية. تم وضع الغرسات في القوالب باستخدام مجموعة موجهة بالكامل باستخدام بروتوكول حفر متسلسل ، وتم تقييم كل دليل على الصب المرجعي للتحقق من المقاعد أولاً ، بعد الحفر ووضع الغرس الناجح ، تمت إعادة مسح المجموعة بأكملها باستخدام الماسح الضوئي فوق الغرسة المُدخلة بواسطة نفس الماسح الضوئي السابق خارج الفم ، تمت محاذاة كل عينة تقريبًا باستخدام أدوات محاذاة CAD خاصة من (exocad) للتصميم الرقمي المقابل لتحديد الانحراف وعدم المحاذاة بينهما. أكدت اختبارات التوزيع الطبيعي )شابيرو-ويلك وكولموغوروف-سميرنوف( توزيع البيانات الكمية بشكل طبيعي ) p > 0.05 (. والنتائج كانت غير ملموسة احصائيا ولكنها كانت ذات دلالة إكلينيكية بين المجموعتين فيما يتعلق بالأبعاد الخد اللساني ) p = 0.83 ( والانثي الوحشي) p = 0.41 ( والعمق ) p = 0.75 (. وكانت القيم المتوسطة للقياسات الخد اللساني والانثي الوحشي والعمق متشابهة بين المجموعتين. ومن نتائج هذه الدراسة يمكن استنتاج: إمكانية المنصات مفتوحة المصدر في تخطيط غرسة الأسنان وصناعة الأدلة الجراحية، مما يوفر بديلاً فعالاً من حيث التكلفة وأكثر سهولة الوصول إلى الأطباء.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2025.Jo.A (Browse shelf(Opens below)) Not for loan 01010110092268000

Thesis (M.Sc)-Cairo University, 2025.

Bibliography: pages 107-116.

Aim: The aim of this in vitro study was to compare the accuracy of implant placement when using tooth supported surgical guide using a fully guided surgical guide design performed on different softwares of them are non-dental software (Blenderfordental) versus a dental software (Exoplan).

Methodology: Twenty study models, simulating patients with a missing upper left first molar, were divided into two groups: Group I (Exoplan) and Group II (Blender). Each group underwent digital implant planning and surgical guide fabrication using their respective software. A typodont model was digitally scanned and segmented to create a virtual model. This model was further processed to serve as the basis for implant planning. DICOM data from a CBCT scan of a physical model were integrated into the planning software to enhance accuracy. Implant planning was performed using a top-down approach, considering prosthetic requirements and selecting an appropriate implant from the software's library. Surgical guides were designed and fabricated using the software's features, ensuring accurate implant placement and minimizing surgical invasiveness. After implant placement, scanbodies were attached to the implants, and postoperative scans were acquired. By superimposing the preoperative and postoperative scans, deviations in implant position were measured along the buccolingual, mesiodistal, and apico-coronal axes.

Results: Normality tests (Shapiro-Wilk and Kolmogorov-Smirnov) confirmed the normal distribution of quantitative data (p > 0.05). No statistically significant differences were found between the two groups for buccolingual (p = 0.83), mesiodistal (p = 0.41), and depth (p = 0.75) dimensions. Mean values for buccolingual, mesiodistal, and depth measurements were comparable between groups.

Conclusion: Open-source software designed for non-dental applications, such as Blender, can be utilized to create dental implant surgical guides with accuracy that is not significantly different from commercially available dental implant treatment planning software like Exoplan. Both Exoplan and Blender groups demonstrated statistically not significant deviations from the ideal implant position along all three axes. These findings suggest that open-source software can be used for dental implant surgical guide fabrication.

أجريت هذه الدراسة للمقارنة بين دقة برنامج ) Blender ( الذي تم تطويره من قبل المنظمات المهنية غير المتخصصة في
طب الأسنان و Exoplan لاختبار دقة المكتبات المضمنة ودقتها وقدرة أدواتها على جمع البيانات. بشكل صحيح لتكون ودودًا في استخدام الأسنان باستخدام أدلة جراحية مدعومة بالأسنان بالكامل
في هذه الدراسة باستخدام تصميمات مسبقة الطباعة لتلائم هذا البحث وموحدة من خلال الدراسة بأكملها ، تم تصميم القالب
باستخدام ضرس واحد مفقود وتم تحضيره كقالب مرجعي ، ثم تم تشميع الأسنان المفقودة ثم تم مسح نماذج الدراسة بشكل فردي
باستخدام ماسح ضوئي خارج الفم. ثم تم إنشاء ملفات DICOM للمرجعية عن طريق مسح CBCT ، تم إجراء تخطيطين مختلفين
للغرس باستخدام برنامج طب الأسنان ) Exoplan ( وبرنامج CAD غير خاص بالأسنان ) Blender ( ، كل منها يتضمن تخطيط
الغرس ، ووضع الغرسة الافتراضية وتصنيع دليل جراحي مدعوم بالأسنان على أسنان متجاورة باستخدام نفس سير العمل العام لكل
برنامج باستخدام تصميم دليل معياري ومتغيرات إنتاج توجيهية. تم وضع الغرسات في القوالب باستخدام مجموعة موجهة بالكامل
باستخدام بروتوكول حفر متسلسل ، وتم تقييم كل دليل على الصب المرجعي للتحقق من المقاعد أولاً ،
بعد الحفر ووضع الغرس الناجح ، تمت إعادة مسح المجموعة بأكملها باستخدام الماسح الضوئي فوق الغرسة المُدخلة بواسطة
نفس الماسح الضوئي السابق خارج الفم ، تمت محاذاة كل عينة تقريبًا باستخدام أدوات محاذاة CAD خاصة من (exocad) للتصميم
الرقمي المقابل لتحديد الانحراف وعدم المحاذاة بينهما.
أكدت اختبارات التوزيع الطبيعي )شابيرو-ويلك وكولموغوروف-سميرنوف( توزيع البيانات الكمية بشكل طبيعي ) p > 0.05 (. والنتائج كانت غير ملموسة احصائيا ولكنها كانت ذات دلالة إكلينيكية بين المجموعتين فيما يتعلق بالأبعاد الخد اللساني ) p = 0.83 ( والانثي الوحشي) p = 0.41 ( والعمق ) p = 0.75 (. وكانت القيم المتوسطة للقياسات الخد اللساني والانثي الوحشي والعمق
متشابهة بين المجموعتين.
ومن نتائج هذه الدراسة يمكن استنتاج: إمكانية المنصات مفتوحة المصدر في تخطيط غرسة الأسنان وصناعة الأدلة الجراحية، مما
يوفر بديلاً فعالاً من حيث التكلفة وأكثر سهولة الوصول إلى الأطباء.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library