Image from OpenLibrary

Evaluation of shear bond strength of vita lumex versus vita vm9 veneered to zirconia substructure : an in-vitro study by Sarah Abdulrazzaq Ali Almesbahi ; Supervisors Prof. Dr. Ahmed Hassanien Khalil, Dr. Eman Ezzat Youssef.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2024Description: 93 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تقييم قوة الرابطة القصية للفيتالوماكس وفيتا (في ام 9) المغطاة لقاعدة زركونيا : دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.69
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2024. Summary: Aim: This study was designed to evaluate the shear bond strength of VITA LUMEX Versus VITA VM 9 veneered on a high translucent zirconia substructure. And detect the mode of failure by Scanning Electron Microscope (SEM) analysis. Methodology: Twenty-eight discs of high translucent zirconia (7mm diameter and 3mm thickness) were milled from partially sintered zirconia (Ceramill Zolid ht+ white Blank). After the sintering procedure, all samples were air-abraded with 50µm aluminum oxide (Al2O3) particles at 2 bar pressure for 10 Seconds with a nozzle distance of approximately 10 mm. All samples were randomly divided into 2 groups based on the veneering materials used. Group LX (n= 14): layered with leucite- reinforced glass-ceramic (VITA LUMEX), and Group VM (n= 14): layered with feldspathic ceramic (VITA VM 9) with standardized dimensions of (4mm diameter and 3mm thickness). Samples were subjected to thermocycling (5,000 cycles) and shear bond strength was tested using a universal testing, by compressive static load applied at the veneer-substrate interface, at a cross-head speed of 1.0 mm/min, until failure occurred. The mean and standard deviation of shear bond strength for each group were calculated, and statistically compared using independent t-test. The failure modes of fractured samples were initially evaluated using a stereomicroscope followed by examination under a scanning electron microscope (SEM) and EDX. Results: The shear bond strength in Group LX (19.45 ± 5.51 Mpa) was insignificantly lower than in Group VM (22.44 ± 8.29 Mpa) with a (2.99 ± 2.66 Mpa) difference between them as P=0.27. Regarding the mode of failure assessment, all specimens in both groups exhibited mixed modes of failure, except for one specimen in Group LX, which showed cohesive failure. Conclusions: Leucite-reinforced veneering ceramic (VITA LUMEX) and feldspathic veneering ceramic (VITA VM9) exhibited comparable shear bond strength when used to veneer high translucent zirconia substructure (Ceramill® Zolid ht+ white). Both groups showed similar results, with a predominant mixed mode of failure. Summary: هدفت هذه الدراسة إلى تقييم قوة الترابط القصي بين VITA LUMEXوVITA VM 9 عند تغليفها على ركائز الزركونيا عالية الشفافية، وتحديد نمط الفشل باستخدام تحليل المجهر الإلكتروني الماسح (SEM). تم لهذا الغرض تصنيع ثمانية وعشرين قرصاً من الزركونيا عالية الشفافية بأبعاد (٧ × ٣ مم) من أقراص الزركونيا الملبدة جزئياً. تم تلبيد جميع العينات بالكامل عند درجة حرارة ١٤٥٠°C وفقًا لتعليمات الشركة المصنعة. وتم تنعيمها بجسيمات أكسيد الألومنيوم (Al2O3) بحجم ٥٠ ميكرومتر تحت ضغط ٢ بار لمدة ١٠ ثوانٍ، مع الحفاظ على مسافة الفوهة عند ١٠ ملم تقريبًا. تم تقسيم جميع العينات إلى مجموعتين: (مجموعة LX) التي تم تغليفها بخزف مقوى باللوكسايت (VITA LUMEX)، و (مجموعة VM) التي تم تغليفها بخزف فلسباثي (VITA VM 9) باستخدام تقنية الطبقات بأبعاد قياسية (٤ × ٣ مم). جميع الخطوات تمت وفقًا لتعليمات الشركة المصنعة. تم تعريض العينات لدورة حرارية تصل إلى ٥٠٠٠ دورة بين درجتي حرارة ٥°Cو٥٥°C، مع وقت بقاء ٣٠ ثانية عند كل درجة حرارة في الماء المقطر. جُهزت جميع العينات لتحميلها حتى الفشل باستخدام جهاز اختبار شامل. تم تقييم العينات الفاشلة باستخدام مجهر استريوسكوبي ثم فحصها باستخدام المجهر الإلكتروني الماسح (SEM) والتحليل الطيفي بالأشعة السينية (EDX) لتحديد نمط الفشل. أظهرت النتائج أن المتوسط والانحراف المعياري لمجموعة LX (١٩.٤٥ ± ٥.٥١ ميجا باسكال) كانت أقل بشكل غير دال عن مجموعة VM (٢٢.٤٤ ± ٨.٢٩ ميجا باسكال) بفارق (٢.٩٩ ± ٢.٦٦ ميجا باسكال) بينهما. بالنسبة لتقييم نمط الفشل، أظهرت جميع العينات في كلا المجموعتين أنماط فشل مختلطة، باستثناء عينة واحدة في مجموعة LX، التي أظهرت فشلًا تماسيًا. في هذه الدراسة، يمكن الاستنتاج أن: • الخزف المقوى بالليوسيت (VITA LUMEX) والخزف الزجاجي الفلسباثي (VITA VM9) أظهرا قوة ربط قص مقاربة عند استخدامهما لتغطية الهيكل الزيركوني العالي الشفافية (Ceramill® Zolidht+ white). • كلا المادتين أظهرتا قيم قوة ربط قص أعلى من الحد الأدنى المقبول سريريًا. • كلا المجموعتين أظهرتا نتائج مشابهة مع نمط فشل مختلط سائد.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2024.Sa.E (Browse shelf(Opens below)) Not for loan 01010110092776000

Thesis (M.Sc)-Cairo University, 2024.

Bibliography: pages 85-93.

Aim: This study was designed to evaluate the shear bond strength of VITA LUMEX Versus VITA
VM 9 veneered on a high translucent zirconia substructure. And detect the mode of failure by
Scanning Electron Microscope (SEM) analysis.
Methodology: Twenty-eight discs of high translucent zirconia (7mm diameter and 3mm thickness)
were milled from partially sintered zirconia (Ceramill Zolid ht+ white Blank). After the sintering
procedure, all samples were air-abraded with 50µm aluminum oxide (Al2O3) particles at 2 bar
pressure for 10 Seconds with a nozzle distance of approximately 10 mm. All samples were randomly
divided into 2 groups based on the veneering materials used. Group LX (n= 14): layered with leucite-
reinforced glass-ceramic (VITA LUMEX), and Group VM (n= 14): layered with feldspathic ceramic
(VITA VM 9) with standardized dimensions of (4mm diameter and 3mm thickness). Samples were
subjected to thermocycling (5,000 cycles) and shear bond strength was tested using a universal
testing, by compressive static load applied at the veneer-substrate interface, at a cross-head speed of
1.0 mm/min, until failure occurred. The mean and standard deviation of shear bond strength for each
group were calculated, and statistically compared using independent t-test. The failure modes of
fractured samples were initially evaluated using a stereomicroscope followed by examination under
a scanning electron microscope (SEM) and EDX.
Results: The shear bond strength in Group LX (19.45 ± 5.51 Mpa) was insignificantly lower than in
Group VM (22.44 ± 8.29 Mpa) with a (2.99 ± 2.66 Mpa) difference between them as P=0.27.
Regarding the mode of failure assessment, all specimens in both groups exhibited mixed modes of
failure, except for one specimen in Group LX, which showed cohesive failure.
Conclusions: Leucite-reinforced veneering ceramic (VITA LUMEX) and feldspathic veneering
ceramic (VITA VM9) exhibited comparable shear bond strength when used to veneer high translucent
zirconia substructure (Ceramill® Zolid ht+ white). Both groups showed similar results, with a
predominant mixed mode of failure.

هدفت هذه الدراسة إلى تقييم قوة الترابط القصي بين VITA LUMEXوVITA VM 9 عند تغليفها على ركائز الزركونيا عالية الشفافية، وتحديد نمط الفشل باستخدام تحليل المجهر الإلكتروني الماسح (SEM).
تم لهذا الغرض تصنيع ثمانية وعشرين قرصاً من الزركونيا عالية الشفافية بأبعاد (٧ × ٣ مم) من أقراص الزركونيا الملبدة جزئياً. تم تلبيد جميع العينات بالكامل عند درجة حرارة ١٤٥٠°C وفقًا لتعليمات الشركة المصنعة. وتم تنعيمها بجسيمات أكسيد الألومنيوم (Al2O3) بحجم ٥٠ ميكرومتر تحت ضغط ٢ بار لمدة ١٠ ثوانٍ، مع الحفاظ على مسافة الفوهة عند ١٠ ملم تقريبًا. تم تقسيم جميع العينات إلى مجموعتين: (مجموعة LX) التي تم تغليفها بخزف مقوى باللوكسايت (VITA LUMEX)، و (مجموعة VM) التي تم تغليفها بخزف فلسباثي (VITA VM 9) باستخدام تقنية الطبقات بأبعاد قياسية (٤ × ٣ مم). جميع الخطوات تمت وفقًا لتعليمات الشركة المصنعة.
تم تعريض العينات لدورة حرارية تصل إلى ٥٠٠٠ دورة بين درجتي حرارة ٥°Cو٥٥°C، مع وقت بقاء ٣٠ ثانية عند كل درجة حرارة في الماء المقطر. جُهزت جميع العينات لتحميلها حتى الفشل باستخدام جهاز اختبار شامل. تم تقييم العينات الفاشلة باستخدام مجهر استريوسكوبي ثم فحصها باستخدام المجهر الإلكتروني الماسح (SEM) والتحليل الطيفي بالأشعة السينية (EDX) لتحديد نمط الفشل.
أظهرت النتائج أن المتوسط والانحراف المعياري لمجموعة LX (١٩.٤٥ ± ٥.٥١ ميجا باسكال) كانت أقل بشكل غير دال عن مجموعة VM (٢٢.٤٤ ± ٨.٢٩ ميجا باسكال) بفارق (٢.٩٩ ± ٢.٦٦ ميجا باسكال) بينهما. بالنسبة لتقييم نمط الفشل، أظهرت جميع العينات في كلا المجموعتين أنماط فشل مختلطة، باستثناء عينة واحدة في مجموعة LX، التي أظهرت فشلًا تماسيًا.
في هذه الدراسة، يمكن الاستنتاج أن:
• الخزف المقوى بالليوسيت (VITA LUMEX) والخزف الزجاجي الفلسباثي (VITA VM9) أظهرا قوة ربط قص مقاربة عند استخدامهما لتغطية الهيكل الزيركوني العالي الشفافية (Ceramill® Zolidht+ white).
• كلا المادتين أظهرتا قيم قوة ربط قص أعلى من الحد الأدنى المقبول سريريًا.
• كلا المجموعتين أظهرتا نتائج مشابهة مع نمط فشل مختلط سائد.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library