Renewables hosting capacity maximization in electric distribution systems operating under non-sinusoidal conditions / by Sara Usama Ahmed Elzainy ; Supervisors Prof. Dr. Ahmed Mohamed Ibrahim.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2024Description: 98 pages : illustrations ; 30 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تعظيم قدرة إستضافة الطاقات المتجددة في أنظمة التوزيع الكهربية التي تعمل في ظل ظروف غير جيبية [Added title page title]
Subject(s): DDC classification:
  • 621.319
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2024. Summary: Using renewable sources as an alternative in modern distribution systems has been of a great interest nowadays due to its environmental benefits as well as the various technical benefits that can be gained. However, adding renewables to distribution systems may also cause complications in power grids if it’s not correctly placed or sized. Some of the common issues could be caused due to the mixture of nonlinear loads and inverter-based renewable sources, as well as over-voltages and under-voltages occurrences. These problems arise when the rating of distributed generation units exceeds the maximum allowable level of renewables penetration that is known as hosting capacity. This thesis deals with multiple types of inverter-based DG sources, such as Photovoltaics and fuel cells. Three optimization techniques are used to get the maximum allowed HC. These techniques are the wild horse optimization, whale optimization algorithm, and harris hawk optimization algorithms. A damped C-type passive filter is designed to reduce the harmonic distortion. Several constraints have been taken into consideration in addition to the IEEE 519 standard and the Egyptian distribution code to keep the system under the acceptable operational limits. The results obtained indicates that the approaches used was effective and the system had a significant improvement in its performance comparing to the other techniques used in the previous studies.Summary: لقد أصبح استخدام المصادر المتجددة كبديل في أنظمة التوزيع الحديثة يحظى باهتمام كبير في الوقت الحاضر نظرًا لفوائده البيئية بالإضافة إلى الفوائد التقنية المختلفة التي يمكن الحصول عليها. ومع ذلك، فإن إضافة مصادر الطاقة المتجددة إلى أنظمة التوزيع قد يسبب أيضًا تعقيدات في شبكات الطاقة إذا لم يتم وضعها أو اختيار حجمها بشكل صحيح. بعض المشكلات الشائعة قد تحدث نتيجة خليط الأحمال غير الخطية والمصادر المتجددة ذات العاكس، بالإضافة إلى إمكانية حدوث مشاكل الجهد الزائد أو الجهد المنخفض. تنشأ هذه المشاكل عندما يتجاوز تصنيف وحدات التوليد الموزعة الحد الأقصى المسموح به لانتشار مصادر الطاقة المتجددة والذي يعرف بقدرة الاستضافة. تتناول هذه الرسالة أنواعًا متعددة من مصادر وحدات التوليد الموزعة المعتمدة على العاكس، مثل الخلايا الكهروضوئية وخلايا الوقود. تم استخدام ثلاث تقنيات للتحسين للحصول على الحد الأقصى المسموح به من قدرة الاستضافة. هذه التقنيات هي تحسين الحصان البري، وخوارزمية تحسين الحيتان، وخوارزميات تحسين الصقور. تم تصميم مرشح مخمد غير فعال من النوع C لتقليل التشوه التوافقي. قد تم أخذ العديد من القيود بعين الاعتبار بالإضافة إلى توصياتIEEE 519 والكود المصري للكهرباء لإبقاء النظام ضمن الحدود التشغيلية المقبولة. تشير النتائج التي تم الحصول عليها إلى أن الأساليب المستخدمة كانت فعالة وأن النظام شهد تحسنا كبيرا في أدائه مقارنة بالتقنيات الأخرى المستخدمة في الدراسات السابقة.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2024.Sa.R (Browse shelf(Opens below)) Not for loan 01010110092970000

Thesis (M.Sc)-Cairo University, 2024.

Bibliography: pages 77-87.

Using renewable sources as an alternative in modern distribution systems has been of a great interest nowadays due to its environmental benefits as well as the various technical benefits that can be gained. However, adding renewables to distribution systems may also cause complications in power grids if it’s not correctly placed or sized. Some of the common issues could be caused due to the mixture of nonlinear loads and inverter-based renewable sources, as well as over-voltages and under-voltages occurrences. These problems arise when the rating of distributed generation units exceeds the maximum allowable level of renewables penetration that is known as hosting capacity. This thesis deals with multiple types of inverter-based DG sources, such as Photovoltaics and fuel cells. Three optimization techniques are used to get the maximum allowed HC. These techniques are the wild horse optimization, whale optimization algorithm, and harris hawk optimization algorithms. A damped C-type passive filter is designed to reduce the harmonic distortion. Several constraints have been taken into consideration in addition to the IEEE 519 standard and the Egyptian distribution code to keep the system under the acceptable operational limits. The results obtained indicates that the approaches used was effective and the system had a significant improvement in its performance comparing to the other techniques used in the previous studies.

لقد أصبح استخدام المصادر المتجددة كبديل في أنظمة التوزيع الحديثة يحظى باهتمام كبير في الوقت الحاضر نظرًا لفوائده البيئية بالإضافة إلى الفوائد التقنية المختلفة التي يمكن الحصول عليها. ومع ذلك، فإن إضافة مصادر الطاقة المتجددة إلى أنظمة التوزيع قد يسبب أيضًا تعقيدات في شبكات الطاقة إذا لم يتم وضعها أو اختيار حجمها بشكل صحيح. بعض المشكلات الشائعة قد تحدث نتيجة خليط الأحمال غير الخطية والمصادر المتجددة ذات العاكس، بالإضافة إلى إمكانية حدوث مشاكل الجهد الزائد أو الجهد المنخفض. تنشأ هذه المشاكل عندما يتجاوز تصنيف وحدات التوليد الموزعة الحد الأقصى المسموح به لانتشار مصادر الطاقة المتجددة والذي يعرف بقدرة الاستضافة. تتناول هذه الرسالة أنواعًا متعددة من مصادر وحدات التوليد الموزعة المعتمدة على العاكس، مثل الخلايا الكهروضوئية وخلايا الوقود. تم استخدام ثلاث تقنيات للتحسين للحصول على الحد الأقصى المسموح به من قدرة الاستضافة. هذه التقنيات هي تحسين الحصان البري، وخوارزمية تحسين الحيتان، وخوارزميات تحسين الصقور. تم تصميم مرشح مخمد غير فعال من النوع C لتقليل التشوه التوافقي. قد تم أخذ العديد من القيود بعين الاعتبار بالإضافة إلى توصياتIEEE 519 والكود المصري للكهرباء لإبقاء النظام ضمن الحدود التشغيلية المقبولة. تشير النتائج التي تم الحصول عليها إلى أن الأساليب المستخدمة كانت فعالة وأن النظام شهد تحسنا كبيرا في أدائه مقارنة بالتقنيات الأخرى المستخدمة في الدراسات السابقة.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library