Image from OpenLibrary

Properties of concrete incorporating recycled lightweight aggregate from autoclaved aerated concrete (AAC) / by Zyad Mohamed Saad Morssy Saleh ; Supervisors Prof. Dr. Hatem Hassan Ali Ibrahim, Prof. Dr. Mohamed Karam Hussein Ismail.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2025Description: 80 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • خصائص الخرسانة المحتوية على ركام خفيف المعاد تدويره من الخرسانة الخلوية (Autoclave Aerated Concrete-AAC) [Added title page title]
Subject(s): DDC classification:
  • 624.1834
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2025. Summary: This study evaluates recycled autoclave-aerated concrete aggregate (AACA) as a sustainable substitute for natural coarse aggregate (NCA) in structural concrete. Sixteen mixtures spanning 0–100% AACA were produced, including optimized variants with silica fume (SF), tuned coarse-to-fine aggregate ratios (C/F), and hooked/corrugated steel fibers. A comprehensive program measured slump, dry density, compressive/splitting/flexural strengths, UPV, Schmidt rebound, water absorption, sorptivity, abrasion, and impact on cylinders and beams. Embodied energy for manual AACA processing was quantified experimentally via real-time metabolic energy expenditure to enable an energy-based sustainability appraisal. Increasing AACA generally reduced mechanical performance and increased transport properties. Targeted optimization mitigated penalties: SF densified the paste/ITZ and lowered transport, C/F tuning improved packing and reduced capillary connectivity, and steel fibers enhanced post-crack behavior and impact resistance. Select 75% AACA + 1% steel-fiber mixes achieved f′c ≥ 17 MPa with density < 1920 kg/m³ (meeting ACI 213R-14 lightweight criteria), while several ~30–50% AACA mixes met the CSA A23.1/23.3 structural strength threshold (f′c ≥ 20 MPa) within semi-lightweight density bands (1850–2150 kg/m³), supporting AACA’s use in lightweight/semi-lightweight applications when paired with moisture control, SF, C/F optimization, and fibers. Summary: تبحث هذه الدراسة جدوى استخدام ركام الخرسانة الخلوية المُعالجة بالأوتوكلاف والمعاد تدويره (AACA) كبديل مستدام للركام الخشن الطبيعي في الخرسانة الإنشائية. تم تطوير 16 خلطة خرسانية بنسب إحلال مختلفة لـ AACA (من 0% إلى 100%)، مع تطبيق تحسينات من خلال استخدام غبار السيليكا (SF)، وتعديل نسبة الركام الخشن إلى الناعم (C/F)، وتسليح الخلطات بألياف فولاذية خطّافية ومموجة.شمل التقييم خصائص الخرسانة في حالتيها الطازجة والمتصلدة، بما في ذلك: الهبوط، الكثافة الجافة، مقاومة الضغط، الشد غير المباشر، الانثناء، سرعة الموجات فوق الصوتية (UPV)، رقم ارتداد شميدت، الامتصاص الكلي، الامتصاصية الشعرية، مقاومة البري، ومقاومة الصدم. كما تم قياس الطاقة المطلوبة لإعادة تدوير AACA تجريبيًا لتحليل الجدوى البيئية.أظهرت النتائج أن زيادة نسبة إحلال AACA تؤدي إلى تراجع في الأداء الميكانيكي وارتفاع في النفاذية نتيجة لبنيته الخلوية عالية المسامية. ومع ذلك، ساهمت استراتيجيات التحسين (SF، الألياف الفولاذية، ضبط C/F) في تقليل هذه الآثار وتحقيق تحسّن في الأداء، مما يجعلها مناسبة لمتطلبات الخرسانة خفيفة الوزن. كما أثبتت خلطات أخرى فعالية مقبولة للاستخدامات الإنشائية.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2025.Zy.P (Browse shelf(Opens below)) Not for loan 01010110093700000

Thesis (M.Sc)-Cairo University, 2025.

Bibliography: pages 75-80.

This study evaluates recycled autoclave-aerated concrete aggregate (AACA) as a
sustainable substitute for natural coarse aggregate (NCA) in structural concrete. Sixteen
mixtures spanning 0–100% AACA were produced, including optimized variants with
silica fume (SF), tuned coarse-to-fine aggregate ratios (C/F), and hooked/corrugated steel
fibers. A comprehensive program measured slump, dry density,
compressive/splitting/flexural strengths, UPV, Schmidt rebound, water absorption,
sorptivity, abrasion, and impact on cylinders and beams. Embodied energy for manual
AACA processing was quantified experimentally via real-time metabolic energy
expenditure to enable an energy-based sustainability appraisal. Increasing AACA
generally reduced mechanical performance and increased transport properties. Targeted
optimization mitigated penalties: SF densified the paste/ITZ and lowered transport, C/F
tuning improved packing and reduced capillary connectivity, and steel fibers enhanced
post-crack behavior and impact resistance. Select 75% AACA + 1% steel-fiber mixes
achieved f′c ≥ 17 MPa with density < 1920 kg/m³ (meeting ACI 213R-14 lightweight
criteria), while several ~30–50% AACA mixes met the CSA A23.1/23.3 structural
strength threshold (f′c ≥ 20 MPa) within semi-lightweight density bands (1850–2150
kg/m³), supporting AACA’s use in lightweight/semi-lightweight applications when
paired with moisture control, SF, C/F optimization, and fibers.

تبحث هذه الدراسة جدوى استخدام ركام الخرسانة الخلوية المُعالجة بالأوتوكلاف والمعاد تدويره (AACA) كبديل مستدام للركام الخشن الطبيعي في الخرسانة الإنشائية. تم تطوير 16 خلطة خرسانية بنسب إحلال مختلفة لـ AACA (من 0% إلى 100%)، مع تطبيق تحسينات من خلال استخدام غبار السيليكا (SF)، وتعديل نسبة الركام الخشن إلى الناعم (C/F)، وتسليح الخلطات بألياف فولاذية خطّافية ومموجة.شمل التقييم خصائص الخرسانة في حالتيها الطازجة والمتصلدة، بما في ذلك: الهبوط، الكثافة الجافة، مقاومة الضغط، الشد غير المباشر، الانثناء، سرعة الموجات فوق الصوتية (UPV)، رقم ارتداد شميدت، الامتصاص الكلي، الامتصاصية الشعرية، مقاومة البري، ومقاومة الصدم. كما تم قياس الطاقة المطلوبة لإعادة تدوير AACA تجريبيًا لتحليل الجدوى البيئية.أظهرت النتائج أن زيادة نسبة إحلال AACA تؤدي إلى تراجع في الأداء الميكانيكي وارتفاع في النفاذية نتيجة لبنيته الخلوية عالية المسامية. ومع ذلك، ساهمت استراتيجيات التحسين (SF، الألياف الفولاذية، ضبط C/F) في تقليل هذه الآثار وتحقيق تحسّن في الأداء، مما يجعلها مناسبة لمتطلبات الخرسانة خفيفة الوزن. كما أثبتت خلطات أخرى فعالية مقبولة للاستخدامات الإنشائية.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library