صور من OpenLibrary

Effect of archwire gauge on the rate of canine retraction in adults : a randomized clinical trial / by Aml Saeed Mohamed Akl ; Supervised Amr Hussein Labib , Fouad A. El Sharaby , Heba M. Dehis.

بواسطة: المساهم: نوع المادة : نصاللغة: الإنجليزية لغة الملخص: الإنجليزية, العربية المنتج: 2022الوصف: 184 pages : illustrations ; 25 cm. + CDنوع المحتوى:
  • text
نوع الوسائط:
  • Unmediated
نوع الناقل:
  • volume
عنوان آخر:
  • تأثير مقياس السلك على معدل سحب الناب في البالغين : تجربة سريرية عشوائية [عنوان مضاف عنوان الصفحة]
الموضوع: تصنيف ديوي العشري:
  • 610
Available additional physical forms:
  • Issues also as CD.
ملاحظة الأطروحة: Thesis (M.Sc.)-Cairo University- Faculty of Oral and Dental Medicine ملخص: The current study was conducted to investigate the effect of wire gauge on rate and type of tooth movement during sliding mechanics and its effect on root resorption of the teeth moved and amount of anchorage loss. Total of 36 canines of eighteen adult female patients with age range (16-26) years old who had dento-alveolar maxillary protrusion necessitating extraction of the maxillary first premolars were investigated in the study. Canines were retracted using Ni-Ti coil spring extending between canines’ brackets and second molars’ tubes which was used for anchorage while no additional anchorage means were used. Canines were retracted with 1.5 N force over three archwire gauges (0.016Ⅹ0.022”, 0.017Ⅹ0.025” and 0.19Ⅹ0.025”) St.St wires in three-arm parallel group study. 3D digital models were used in the assessment of monthly canine retraction rate, which was the primary outcome of the study and amount of first molar anchorage loss that was secondary outcome. CBCT images were used in the assessment of other secondary outcomes; amount of canine root resorption, change in canine tipping, torque and rotation occurred after 6 months of retraction. The results revealed that there was small difference in the mean rate of canine retraction between the three groups as canine was retracted by 1.01, 0.67 and 0.7 mm/month in 0.016Ⅹ0.022”, 0.017Ⅹ0.025” and 0.19Ⅹ0.025” St.St groups, respectively with no statistical significant difference between all groups (P-value=0.2). Canine tipping increased with the decrease in archwire gauge yet that tipping was of no statistical or clinical significant difference (P-value=0.085, CI= 8.15-11.42). Root resorption was significantly higher in 0.19Ⅹ0.025” St.St group 1.39±1.23 mm than the other two groups (0.5±0.66 and 0.41±0.55) mm in 0.016Ⅹ0.022” and 0.017Ⅹ0.025” St.St groups (pvalue=0.024). Additionally, there was statistical significant difference between 0.016Ⅹ0.022” and 0.017Ⅹ0.025” St.St groups regarding amount of anchorage loss (P-value=0.028) with no statistical significance between any other two groups. The mean value of anchorage loss was 1.71, 2.99 and 2.72 mm in 0.016Ⅹ0.022”, 0.017Ⅹ0.025” and 0.19Ⅹ0.025” St.St correspondingly. For the other outcomes, there was no significant difference among the groups. Within the limitation of the current study, archwire gauge has little effect on rate of canine retraction, tipping, torque or rotation with no statistical or clinical significance. Smaller archwire gauges have less adverse effect on anchor units and root resorption compared to larger archwiresملخص: •الدراسه المقدمه اجريت من اجل تقييم تأثير حجم السلك على معدل و طريقة حركة الناب خلال سحبه و تأثيره على تآكل جذر الناب المسحوب على السلك و على كميه خسارة الإرساء المقابل لحركة الاسنان. •إجمالي 32 ناب تم فحصهم في 18 بنت بالغه عمرهم يترواح بين 16-26 سنه واللاتي كان لديهم في بروز في الفك العلوي مما يتطلب خلع الضواحك الاولى لعلاج هذا البروز. تم شد الناب بإستخدام الزنبرك الملفوف المصنوع من النيكل و التايتانيوم و الذي امتد بين فص الناب و فص الضرس الثاني المستخدم في الارساء. تم شد الناب بقوة 1.5 نيوتن على ثلاثة احجام مختلفه من الاسلاك المعدنيه (”0.016Ⅹ0.022”,0.017Ⅹ0.025”,0.019Ⅹ0.025) في تجربه سريريه لها ثلاثة ذراع. نماذج ثلاثية الابعاد استخدمت في حساب الغرض الاولي من الدراسه وهو المعدل الشهري لحركة الناب و مسافة تحرك الاسنان المرساه والذي كان غرض ثانوي من البحث. تم استخدام الاشعه المقطعيه ثلاثية الابعاد في حساب اغراض ثويه اخرى وهي: تآكل جذر الناب, التغير في امالة الناب و عزمه و التفافه بعد ستة اشهر من شد الناب. • نتائج البحث اظهرت اختلاف صغير بين الاسلاك في متوسط الشد الشهري لحركة الناب, لقد تحرك بمعدل 1.01 مليميتر و 0.67 مليميتر و 0.7 مليميتر في (”0.016Ⅹ0.022”,0.017Ⅹ0.025”,0.019Ⅹ0.025) بالترتيب ولكن هذا الفرق لم يكن ذو اهميه احصائيه. امالة الناب ازدادت مع تناقص حجم السلك و لكن ايضا لم يكن الفرق ذو اهميه احصائيه او عمليه. ظهر تآكل الناب مع السلك المعدني ”0.019Ⅹ0.025 بمتوسط 1.39± 1.23.بينما كان تآكل الجذر بمتوسط 0.5±0.66 و 0.41±0.55 مع السلكان الاخران و هذا الفارق كان ذو اهميه احصائيه. بالاضافه الى ذلك كمية تحرك الاسان المرساه مع السلك المعدني ”0.017Ⅹ0.025 مقارنة بالسلكان الاخران كان ذو اهميه احصائيه مقارنة بالسلكان الاخران. •في ضوء القيود المفروضه على الدراسه يمكن استنتاج ما يلي: قد يكون هناك تاثير لاحجام الاسلاك المختلفه على حركة الناب و امالته اثناء شده و لكن بدون اهميه احصائيه. ولكن التاثير السلبي علي الاسنان المستخدمه في الارساء و تآكل الجذر اثناء الحركه يكون اقل مع الاسلاك المعدنيه ضغيرة الحجم
وسوم من هذه المكتبة: لا توجد وسوم لهذا العنوان في هذه المكتبة. قم بتسجيل الدخول لإضافة الوسوم.
التقييم باستخدام النجوم
    متوسط التقييم: 0.0 (0 صوتًا)
المقتنيات
نوع المادة المكتبة الحالية المكتبة الرئيسية رقم الاستدعاء حالة الباركود
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.06.M.Sc.2022.Am.E (استعراض الرف(يفتح أدناه)) Not for loan 01010110086564000

استعرض المكتبة المركزبة الجديدة - جامعة القاهرة رفاً إغلاق مستعرض الرف (يخفي مستعرض الرف)

Thesis (M.Sc.)-Cairo University- Faculty of Oral and Dental Medicine

Bibliography: pages 174-180.

The current study was conducted to investigate the effect of wire gauge on rate and type of
tooth movement during sliding mechanics and its effect on root resorption of the teeth moved and
amount of anchorage loss.
Total of 36 canines of eighteen adult female patients with age range (16-26) years old who
had dento-alveolar maxillary protrusion necessitating extraction of the maxillary first premolars were
investigated in the study. Canines were retracted using Ni-Ti coil spring extending between canines’
brackets and second molars’ tubes which was used for anchorage while no additional anchorage
means were used. Canines were retracted with 1.5 N force over three archwire gauges (0.016Ⅹ0.022”,
0.017Ⅹ0.025” and 0.19Ⅹ0.025”) St.St wires in three-arm parallel group study. 3D digital models were
used in the assessment of monthly canine retraction rate, which was the primary outcome of the study
and amount of first molar anchorage loss that was secondary outcome. CBCT images were used in
the assessment of other secondary outcomes; amount of canine root resorption, change in canine
tipping, torque and rotation occurred after 6 months of retraction.
The results revealed that there was small difference in the mean rate of canine retraction
between the three groups as canine was retracted by 1.01, 0.67 and 0.7 mm/month in 0.016Ⅹ0.022”,
0.017Ⅹ0.025” and 0.19Ⅹ0.025” St.St groups, respectively with no statistical significant difference
between all groups (P-value=0.2). Canine tipping increased with the decrease in archwire gauge yet
that tipping was of no statistical or clinical significant difference (P-value=0.085, CI= 8.15-11.42).
Root resorption was significantly higher in 0.19Ⅹ0.025” St.St group 1.39±1.23 mm than the other
two groups (0.5±0.66 and 0.41±0.55) mm in 0.016Ⅹ0.022” and 0.017Ⅹ0.025” St.St groups (pvalue=0.024). Additionally, there was statistical significant difference between 0.016Ⅹ0.022” and
0.017Ⅹ0.025” St.St groups regarding amount of anchorage loss (P-value=0.028) with no statistical
significance between any other two groups. The mean value of anchorage loss was 1.71, 2.99 and
2.72 mm in 0.016Ⅹ0.022”, 0.017Ⅹ0.025” and 0.19Ⅹ0.025” St.St correspondingly. For the other
outcomes, there was no significant difference among the groups.
Within the limitation of the current study, archwire gauge has little effect on rate of canine
retraction, tipping, torque or rotation with no statistical or clinical significance. Smaller archwire
gauges have less adverse effect on anchor units and root resorption compared to larger archwires

•الدراسه المقدمه اجريت من اجل تقييم تأثير حجم السلك على معدل و طريقة حركة الناب خلال سحبه و تأثيره على تآكل جذر الناب المسحوب على السلك و على كميه خسارة الإرساء المقابل لحركة الاسنان.
•إجمالي 32 ناب تم فحصهم في 18 بنت بالغه عمرهم يترواح بين 16-26 سنه واللاتي كان لديهم في بروز في الفك العلوي مما يتطلب خلع الضواحك الاولى لعلاج هذا البروز. تم شد الناب بإستخدام الزنبرك الملفوف المصنوع من النيكل و التايتانيوم و الذي امتد بين فص الناب و فص الضرس الثاني المستخدم في الارساء. تم شد الناب بقوة 1.5 نيوتن على ثلاثة احجام مختلفه من الاسلاك المعدنيه (”0.016Ⅹ0.022”,0.017Ⅹ0.025”,0.019Ⅹ0.025) في تجربه سريريه لها ثلاثة ذراع. نماذج ثلاثية الابعاد استخدمت في حساب الغرض الاولي من الدراسه وهو المعدل الشهري لحركة الناب و مسافة تحرك الاسنان المرساه والذي كان غرض ثانوي من البحث. تم استخدام الاشعه المقطعيه ثلاثية الابعاد في حساب اغراض ثويه اخرى وهي: تآكل جذر الناب, التغير في امالة الناب و عزمه و التفافه بعد ستة اشهر من شد الناب.
• نتائج البحث اظهرت اختلاف صغير بين الاسلاك في متوسط الشد الشهري لحركة الناب, لقد تحرك بمعدل 1.01 مليميتر و 0.67 مليميتر و 0.7 مليميتر في (”0.016Ⅹ0.022”,0.017Ⅹ0.025”,0.019Ⅹ0.025) بالترتيب ولكن هذا الفرق لم يكن ذو اهميه احصائيه. امالة الناب ازدادت مع تناقص حجم السلك و لكن ايضا لم يكن الفرق ذو اهميه احصائيه او عمليه. ظهر تآكل الناب مع السلك المعدني ”0.019Ⅹ0.025 بمتوسط 1.39± 1.23.بينما كان تآكل الجذر بمتوسط 0.5±0.66 و 0.41±0.55 مع السلكان الاخران و هذا الفارق كان ذو اهميه احصائيه. بالاضافه الى ذلك كمية تحرك الاسان المرساه مع السلك المعدني ”0.017Ⅹ0.025 مقارنة بالسلكان الاخران كان ذو اهميه احصائيه مقارنة بالسلكان الاخران.
•في ضوء القيود المفروضه على الدراسه يمكن استنتاج ما يلي: قد يكون هناك تاثير لاحجام الاسلاك المختلفه على حركة الناب و امالته اثناء شده و لكن بدون اهميه احصائيه. ولكن التاثير السلبي علي الاسنان المستخدمه في الارساء و تآكل الجذر اثناء الحركه يكون اقل مع الاسلاك المعدنيه ضغيرة الحجم

Issues also as CD.

Text in English and abstract in Arabic & English.

لا توجد تعليقات على هذا العنوان.

شارك
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library