Simulation of haz in duplex and super duplex stainless steels by heating in the range 475 - 950{u00BA}C/ Maiada Sayed Mahmoud Mahmoud ; Supervised Mohamed R. Elkoussy , Nahed A. Abdelraheem , Randa M. Abdelkarim

By: Contributor(s): Material type: TextLanguage: eng Publication details: Cairo : Maiada Sayed Mahmoud Mahmoud , 2009Description: 130P. : charts , facsimiles ; 30cmOther title:
  • محاكاة المنطقة المتأثرة بالحرارة فى صلب الدوبلكس والسربر دوبلكس بالتسخين فى المنطقة من 475 حتى 950 درجة مئوية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Metallurgical Engineering Summary: The present study was aimed at : a) comparison of the behavior of duplex (DSS) and super duplex (SDSS) in conditions of overheating in the range 475 - 950{u00BA}C, b ) simulate excessive heat input during welding of DSS and SDSS by heating to the 475 - 900{u00BA}C for short time (10 minutes ), c) simulate the conditions of overheating during service and during slow cooling after hot forging of large pieces of SDSS and DSS by heating to the 475 - 950{u00BA}C for longer time (30 and 60 minutes)
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.12.M.Sc.2009.Ma.S (Browse shelf(Opens below)) Not for loan 01010110052544000
CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.12.M.Sc.2009.Ma.S (Browse shelf(Opens below)) 52544.CD Not for loan 01020110052544000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Metallurgical Engineering

The present study was aimed at : a) comparison of the behavior of duplex (DSS) and super duplex (SDSS) in conditions of overheating in the range 475 - 950{u00BA}C, b ) simulate excessive heat input during welding of DSS and SDSS by heating to the 475 - 900{u00BA}C for short time (10 minutes ), c) simulate the conditions of overheating during service and during slow cooling after hot forging of large pieces of SDSS and DSS by heating to the 475 - 950{u00BA}C for longer time (30 and 60 minutes)

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library