The role of high end multi detector CT in coronary imaging / Ahmed Yehia Ahme ; Supervised Seif Eldien Abaza Abdelmonaem , Mohamed Ali Salem
Material type:
- دور الاجيال الحديثه من الأشعه المقطعية متعددة المقاطع في تصوير الشرايين التاجيه [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.31.M.Sc.2012.Ah.R (Browse shelf(Opens below)) | Not for loan | 01010110057681000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.31.M.Sc.2012.Ah.R (Browse shelf(Opens below)) | 57681.CD | Not for loan | 01020110057681000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.11.31.M.Sc.2012.Ah.N New imaging modalities in assessment of pediatric epilepsy / | Cai01.11.31.M.Sc.2012.Ah.N New developments and applications of MR imaging techniques in pancreatic diseases / | Cai01.11.31.M.Sc.2012.Ah.N New developments and applications of MR imaging techniques in pancreatic diseases / | Cai01.11.31.M.Sc.2012.Ah.R The role of high end multi detector CT in coronary imaging / | Cai01.11.31.M.Sc.2012.Ah.R The role of high end multi detector CT in coronary imaging / | Cai01.11.31.M.Sc.2012.Ah.R The role of percutaneous ct guided radiofequency ablation in the treatment of primary and secondry lung malignancis/ | Cai01.11.31.M.Sc.2012.Ah.R The role of percutaneous ct guided radiofequency ablation in the treatment of primary and secondry lung malignancis/ |
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
Prospective gating on 256-slice CT therefore provides a temporal resolution of 135 ms compared with 210 ms on 64-slice CT, the improvement in temporal resolution results in significantly improved image quality for all coronary vessels and reduction of the motion artifacts. The significant difference between 256-slice MDCT and 64-slice MDCT is that 256-slice MDCT requires only two image acquisition to be combined so reduces the stair-step artifact compared five to eight with 64 MDCT, so, the potential for stair-step artifacts is reduced with prospectively gated axial 256-slice CTCA even with higher heart rates
Issued also as CD
There are no comments on this title.