header
Local cover image
Local cover image
Image from OpenLibrary

The role of high end multi detector CT in coronary imaging / Ahmed Yehia Ahme ; Supervised Seif Eldien Abaza Abdelmonaem , Mohamed Ali Salem

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ahmed Yehia Ahme , 2012Description: 122 P. : facsimiles ; 25cmOther title:
  • دور الاجيال الحديثه من الأشعه المقطعية متعددة المقاطع في تصوير الشرايين التاجيه [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis Summary: Prospective gating on 256-slice CT therefore provides a temporal resolution of 135 ms compared with 210 ms on 64-slice CT, the improvement in temporal resolution results in significantly improved image quality for all coronary vessels and reduction of the motion artifacts. The significant difference between 256-slice MDCT and 64-slice MDCT is that 256-slice MDCT requires only two image acquisition to be combined so reduces the stair-step artifact compared five to eight with 64 MDCT, so, the potential for stair-step artifacts is reduced with prospectively gated axial 256-slice CTCA even with higher heart rates
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.31.M.Sc.2012.Ah.R (Browse shelf(Opens below)) Not for loan 01010110057681000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.31.M.Sc.2012.Ah.R (Browse shelf(Opens below)) 57681.CD Not for loan 01020110057681000

Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis

Prospective gating on 256-slice CT therefore provides a temporal resolution of 135 ms compared with 210 ms on 64-slice CT, the improvement in temporal resolution results in significantly improved image quality for all coronary vessels and reduction of the motion artifacts. The significant difference between 256-slice MDCT and 64-slice MDCT is that 256-slice MDCT requires only two image acquisition to be combined so reduces the stair-step artifact compared five to eight with 64 MDCT, so, the potential for stair-step artifacts is reduced with prospectively gated axial 256-slice CTCA even with higher heart rates

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library