Immediate implant placement in the esthetic zone : Socket shield technique versus empty socket technique for preservation of labial alveolar bone integrity / Ahmed Gamal Khater Ali ; Supervised Mohamed Galal Gamal Eldin Beheiri , Mostafa Ibrahim Shindy , Samer Abduljabar Noman

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ahmed Gamal Khater Ali , 2016Description: 87 P. : charts , facsimiles , photoghraphs ; 25cmOther title:
  • وضع الزرعات الفورية في المنطقة الجمالية : تقنية الدرع مقابل تقنية زرع الاسنان في الحال في الحفاظ على مستوى العظام [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery Summary: Objective:The purpose of this study is to evaluate the clinical and radiographic outcomes of socket shield technique compared with conventional immediate implant placement. Materials and Methods:The selected patients will be randomly assigned to the test group (n=10 cases) or the control group (n=10 cases). 20 patients of both genders (17males and 3 females),aged between 18-58 years (average of mean 36 years ) who had remaining roots in the esthetic zone with intact periodontal condition indicated for extraction were included according to the following criteria. Results:The maximum period of treatment will be fixed at nine months. The patient will be examined preoperative and immediate postoperative then nine months during the study period. Conclusion:From our point of view Socket shield technique (SST) was considered as one of successful techniques in preservation of alveolar bone integrity specially in terms of minimal or no alveolar bone loss which is recommended specially in the esthetic zone
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2016.Ah.I (Browse shelf(Opens below)) Not for loan 01010110077934000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2016.Ah.I (Browse shelf(Opens below)) 77934.CD Not for loan 01020110077934000

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery

Objective:The purpose of this study is to evaluate the clinical and radiographic outcomes of socket shield technique compared with conventional immediate implant placement. Materials and Methods:The selected patients will be randomly assigned to the test group (n=10 cases) or the control group (n=10 cases). 20 patients of both genders (17males and 3 females),aged between 18-58 years (average of mean 36 years ) who had remaining roots in the esthetic zone with intact periodontal condition indicated for extraction were included according to the following criteria. Results:The maximum period of treatment will be fixed at nine months. The patient will be examined preoperative and immediate postoperative then nine months during the study period. Conclusion:From our point of view Socket shield technique (SST) was considered as one of successful techniques in preservation of alveolar bone integrity specially in terms of minimal or no alveolar bone loss which is recommended specially in the esthetic zone