Sutureless versus conventional deep scleretomy for open angle glaucoma / Shahenda Ahmed Mohamed ; Supervised Ahmed Mostafa Abdelrahman , Mohamed Sabry Mohamed , Hebatalla Samir Mahmoud Makled
Material type:
TextLanguage: English Publication details: Cairo : Shahenda Ahmed Mohamed , 2020Description: 78 P . : charts , facsimiles ; 25cmOther title: - استئصال الصلبة العميق بدون خياطة مقابل استئصال الصلبة العميق بالخياطة فى علاج المياه الزرقاء فى العيون مفتوحة الزوايا [Added title page title]
- Issued also as CD
| Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
|---|---|---|---|---|---|---|---|
Thesis
|
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.24.Ph.D.2020.Sh.S (Browse shelf(Opens below)) | Not for loan | 01010110082540000 | ||
CD - Rom
|
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.24.Ph.D.2020.Sh.S (Browse shelf(Opens below)) | 82540.CD | Not for loan | 01020110082540000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
Purpose: To compare and evaluate the safety and efficacy of sutureless deep sclerectomy as a substitute for the conventional deep sclerectomy. Design: a prospective clinical trial study. Methods: The study included 60 eyes of 40 patients with medically uncontrolled open angle glaucoma despite maximally tolerated medical therapy. Patients were randomized into two groups, {uF0D8}(Group 1): underwent sutureless deep sclerectomy {uF0D8}(Group 2): underwent conventional deep sclerectomy Intraocularpressure(IOP)wascheckedpreoperativelyand6months postoperatively. Ultrasound bio microscopy (UBM) was done at the first, third, and sixth months post- operatively to follow up the bleb and to evaluate Descemet window. Results: This study reported that percentage of IOP reduction at the sixth month was (51.9%±2), (63.5 % ± 3) compared with the preoperative IOP in group 1 and 2 respectively. Also, a significant difference was found between the number of preoperative and postoperative medications in both groups. P value {u02C2}0,001 No serious complications like endophthalmitis and choroidal detachment were reported during the six months follow up period in both groups.Conclusion: we recommend Sutureless deep sclerectomy as an efficient and safe substitute to conventional technique regarding IOP control and success rates in addition to less ocular irritation, and a better quality of patient{u2019}s life
Issued also as CD
There are no comments on this title.