TY - BOOK AU - Omar Hashem Kamal Mohamed, AU - Nouran Abd Al Naby AU - Nada Sherin El Khourazaty TI - Retention of mandibular implant supported overdentures using CM-LOC and locator attachment systems : : A randomized in vitro study U1 - 617.69 PY - 2020/// KW - Prosthodontics KW - الاستعاضه الصناعية KW - Retention Of Mandibular Implant KW - Supported Overdentures KW - CM-LOC And Locator KW - Attachment Systems N1 - Thesis (M.Sc.)-Cairo University, 2020; Bibliography: pages 86-100; Issues also as CD N2 - Aim: Implant supported overdentures have proved to be a better treatment option compared to conventional dentures in treating edentulous jaws. The present study was carried out to compare the retention of two different types of attachments used to retain single implant supported mandibular overdenture using universal testing machine after mechanical aging that was done by chewing simulator. The two attachments used in this study were Locator and Cendres and Meteaux Locator (CM-LOC). Methodology: Ten epoxy resin models of completely edentulous mandible were constructed and prepared to receive a single implant in the midline area. Ten overdentures were constructed with steel rods fixed to the denture using auto polymerized acrylic resin at the geometric center, two attachment systems; Locator attachmrent with nylon matrix and Cendres &Meteaux Locator (CM-LOC) with a PEKK matrix were investigated, with each type of attachment, the pickup procedure consisted of attaching matrix to the fitting surface of the denture with self-cure acrylic resin. All of the overdentures were subjected to different chewing cycles 500 cycles = (3 month), 1000 cycles = (6 month), 1500 cycles = (9 month) and 2000 cycles = (12 month) , then retention was evaluated using universal testing machine.. Results: The Locator attachment have shown a decrease in retention when subjected to different chewing cycles (p=0.001), with pairwise comparison showing a statistically significant difference between baseline and 2000 cycles ( p=0.011), between 500 cycle and 2000 cycle ( p=0.024). While for the CM-LOC group there was a decrease in retention when subjected to 500, 1000, 1500 cylces ( p=0.001), and with a slight increase in retention after 2000 cycles. With pairwise comparisons there was statistically significant difference at 500 cycles = 3 month and 1500 cycles (9 month). Conclusion: Within in limitation of the present study in vitro study it can be concluded that both the Locator and CM-LOC attachment have shown acceptable retention values to support single implant mandibular retained overdentures. However both attachments have shown a decrease in retention when subjected to different chewing cycles , The CM-LOC attachment has shown significant better retention when compared to Locator attachment after 500 cycles .; اجريت هذه الرسالة لمقارنة القدرة الاحتياطية لنوعين مختلفين من الملحقات المستخدمة للاحتفاظ في الاطقم المدعومة بالزرعة الواحدة بواسطة ألة اختبار علمية بعد التقدم الميكانيكي الذي تم بواسطة جهاز محاكاة المضغ. بينما كانت مجموعة التدخل هي مجموعة CM-LOC وكانت مجموعة التحكم هيLOCATOR تم بناء نموذج ايبوكسي للفك السفلي عديم الاسنان تماماً وتجهيزه لتلقي زرعة واحدة في منطقة خط الوسط. تم بناء عشرة أطقم مفردة خمسة تحتوي على مصفوفة من النايلون وخمسة أخرى تحتوي على مصفوفة من PEEK ثم يتم قياس قيم الاحتفاظ عند خط الاساس باستخدام ألة اختبارعالمية ثم تعرضت الأطقم في كل مجموعة لدورات مضغ مختلفة 500 و 1000 و 1500 و 2000 دورة. تم قياس الاستبقاء طوال هذه الدورات لكلا المجموعتين ER -