TY - BOOK AU - Khadega Hassan Fawzy Hassan, AU - Mohamed Abd El Gawad Zayed AU - Eman Yossri Frag TI - Study the electroanalytical performance of potentiometric electrodes for determination of some metal ions in real samples U1 - 541.372 PY - 2025/// KW - Metal ions KW - أيونات الفلزات KW - Al(III) KW - Flubendazole KW - AL(III)-flubendazole complex KW - CPE KW - Food Stuff KW - Real Water samples KW - DFT/B3LYP KW - Morphological Tools KW - Al(III) quantification KW - applications KW - soil sample KW - الومنيوم KW - ايونوفور N1 - Thesis (M.Sc)-Cairo University, 2025; Bibliography: pages 99-119.; Issues also as CD N2 - A study of structural and electroanalytical chemical properties for both flubendazole and the newly synthesized Al(III)-flubendazole complex (Al-FLU) are explored as potent effectively electroactive sensing ionpohores to construct novel well-defined working chemically modified carbon paste electrodes (CPEs), in both cases the suggested modifier is plasticized with TCP and highly pure graphite powder. Under the optimized conditional parameters, the CPEs (I) and (II) show a high response in the wide linear concentration range of Al(III) from 1.0×10−7 to 1.0×10−1 mole L−1 with limits of detection of 1.0×10−7 mole L−1 for both. They exhibit intended trivalent Nernstian slopes of 20.11± 0.47 mV decade−1 and 20.0± 0.683 mV decade−1 of Al(III) ion activity[Al3+] at 25±1◦C, respectively. Both electrodes showed a fast static response time for about 4.0 and 5.0 s with a reasonable thermal stability beyond the temperature range of 10 to 60°С. The potentiometric response of the electrodes was independent on the pH of the tested solutions in ranges of 3.5–5.0 and 3.4–5.5 for CPEs (I) and (II), respectively. Furthermore, in order to study the response mechanism of the proposed CPEs, the surfaces of the proposed CPEs were characterized using the morphological tools using energy-dispersive X-ray (EDX) equipped with scanning electron microscope (SEM) ,and Fourier Transform Infrared (FT-IR) technique is also applied to confrm the interaction between Al(III) and FLU. Morethan, fortunately this is the first time that Al(III)-flubendazole complex is synthesized and characterized by mass, elemental analysis and computational calculations (DFT and MPA). The developed CPEs are successfully applied quantitative determination of Al(III) ions in drinking water samples, medication(multivitamin syrup), food stuff and soil sample. As well as, CPE(II) is successfully applied for Al(III) ion quantification in both its pure form and for surface soil sample. In order to establish the electrode validation, In accordance with IUPAC recommendation, the validation of the proposed CPEs (I)&(II) are established through integration for both the yield results of the proposed potentiometric CPEs and ICP, that are found to meet the acceptable tolerances.; تضمنت الدراسة استخدام القياس الجهدى لتقدير ايون الألومنيوم بأستخدام اقطاب عجينة الكربون المعدلة كيميائيا باستخدام عقارالفليوبندازول أو مركب الفليوبندازول والألومنيوم حيث تم إستخدامه فى العجينه لقياس كاتيون الألومنيوم .وتم إيضاح العوامل المختلفة التي تؤثر على كفاءة الأقطاب بالتفصيل مثل درجه الحراره ودرجه الحموضه ووقت استجابتها والتداخل وأظهرت الأقطاب المتداخله حساسيه جيده لأيونات الالومنيوم فيما يتعلق بالأيونات المتداخله والكاتيونات الغير عضويه. تم تطبيق اقطاب عجينة الكربون بنجاح لتقدير كاتيون الالومنيوم فى عينات المياه و تم التحقق من هذه الأقطاب المستخدمه وقياس درجه الدقه والحيود والمدى المستقيم وكانت النتائج على اتقان جيد مع النتائج التى تم الحصول عليها بأستخدام الطريقه الرسميه ER -