TY - GEN AU - Karim Ahmed Sharkawy AU - Nasser Osman , AU - Tarek Helmy Abd El Shafy , TI - Locking Compression Plate / PY - 2006/// CY - Cairo : PB - Karim Ahmed Sharkawy , KW - Combination hole KW - Compression KW - internal fixator KW - Locking N1 - Thesis (M.Sc.) - Cairo University - Faculty Of Medicine - Department Of Orthopaedic Surgery; Issued also as CD N2 - Plating techniques remain the mainstay for managing most periarticular and selected long bone fracturesHowever , movement toward more biologically appropriate plating techniques is occurring in an attempt to minimize soft - tissue stripping , decrease the need for bone grafting , and improve union ratesThe locked compression plate (LCP) is a newly developed plating system based on scientific insights into bone biology especially with reference to its blood supply UR - http://172.23.153.220/th.pdf ER -