Respiratory changes in inferior vena cava diameter versus pulse pressure variation in predicting fluid responsiveness in mechanically ventilated septic patients /
دراسة مقارنة بين تغير قطر الوريد الأجوف السفلى أثناء التنفس و تغيرات ضغط النبض فى تقييم الإستجابة للسوائل فى مرضى الإنتناء المتنفسين صناعيا
Mohamed Bakry Aly ; Supervised Mohamed A. Hammouda , Ayman I. Elnaggar , Amr Salah Ibrahim
- Cairo : Mohamed Bakry Aly , 2013
- 216 P. : charts , facsimiles ; 25cm
Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Critical Care Medicine
Knowing whether or not a fluid infusion can improve cardiac output (fluid responsiveness) is a crucial when treating hemodynamically unstable patients. For this reason, new indices, the so-called dynamic indices of fluid responsiveness, have been recently introduced in clinical use. If stroke volume, or stroke volume derived parameters (pulse pressure and aortic flow) show wide variation during mechanical ventilation, a good response to fluid therapy can be predicted