<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03610cam a2200337 a 4500</leader>
  <controlfield tag="003">EG-GiCUC</controlfield>
  <controlfield tag="005">20250223032517.0</controlfield>
  <controlfield tag="008">200122s2019    ua do  f m    000 0 eng d</controlfield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">EG-GiCUC</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">EG-GiCUC</subfield>
  </datafield>
  <datafield tag="041" ind1="0" ind2=" ">
    <subfield code="a">eng</subfield>
  </datafield>
  <datafield tag="049" ind1=" " ind2=" ">
    <subfield code="a">Deposite</subfield>
  </datafield>
  <datafield tag="097" ind1=" " ind2=" ">
    <subfield code="a">M.Sc</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2=" ">
    <subfield code="a">Cai01.09.03.M.Sc.2019.Sa.R</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Safinaz Hussien Fahmy Hassan</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Retention rate of hydroxyapatite nano-fiber reinforced flowable composite versus conventional resin-based flowable composite in initially demineralized pits and fissure : </subfield>
    <subfield code="b">A one year, randomized clinical trial / </subfield>
    <subfield code="c">Safinaz Hussien Fahmy Hassan ; Supervised Mona Ismail Riad , Mai Mamdouh Elsayed</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2="5">
    <subfield code="a">&#x642;&#x64A;&#x627;&#x633; &#x645;&#x639;&#x62F;&#x644; &#x627;&#x644;&#x628;&#x642;&#x627;&#x621; &#x644;&#x644;&#x643;&#x645;&#x628;&#x648;&#x632;&#x64A;&#x62A; &#x627;&#x644;&#x645;&#x639;&#x632;&#x632;  &#x628;&#x627;&#x644;&#x627;&#x644;&#x64A;&#x627;&#x641; &#x627;&#x644;&#x645;&#x62D;&#x62A;&#x648;&#x64A;&#x629; &#x639;&#x644;&#x649;  &#x627;&#x644;&#x647;&#x64A;&#x62F;&#x631;&#x648;&#x643;&#x633;&#x649; &#x627;&#x628;&#x627;&#x62A;&#x64A;&#x62A; &#x627;&#x644;&#x646;&#x627;&#x646;&#x648;&#x645;&#x62A;&#x631;&#x64A;&#x629; &#x645;&#x642;&#x627;&#x628;&#x644; &#x627;&#x644;&#x645;&#x631;&#x643;&#x628; &#x627;&#x644;&#x62A;&#x642;&#x644;&#x64A;&#x62F;&#x649; &#x627;&#x644;&#x642;&#x627;&#x626;&#x645; &#x639;&#x644;&#x649; &#x627;&#x644;&#x631;&#x627;&#x62A;&#x646;&#x62C; &#x627;&#x644;&#x642;&#x627;&#x628;&#x644; &#x644;&#x644;&#x62A;&#x62F;&#x641;&#x642; &#x641;&#x649; &#x628;&#x62F;&#x627;&#x64A;&#x629;  &#x646;&#x632;&#x639; &#x627;&#x644;&#x645;&#x639;&#x627;&#x62F;&#x646; &#x645;&#x646; &#x627;&#x644;&#x62D;&#x641;&#x631; &#x627;&#x644;&#x62F;&#x642;&#x64A;&#x642;&#x629; &#x648; &#x627;&#x644;&#x634;&#x642;&#x648;&#x642; &#x627;&#x644;&#x633;&#x646;&#x64A;&#x629; : </subfield>
    <subfield code="b">&#x62A;&#x62C;&#x631;&#x628;&#x629; &#x639;&#x645;&#x644;&#x64A;&#x629; &#x639;&#x634;&#x648;&#x627;&#x626;&#x64A;&#x629;</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Cairo : </subfield>
    <subfield code="b">Safinaz Hussien Fahmy Hassan , </subfield>
    <subfield code="c">2019</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">94 P.  : </subfield>
    <subfield code="b">charts , photographs ; </subfield>
    <subfield code="c">25cm</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">The study aim was to evaluate the retention rate of Hydroxyapatite Nanofiber reinforced flowable composite compared to conventional resin-based flowable composite during management of initial non cavitated pits and fissures carious lesion in adult population over a one-year period.  A total of 19 volunteer patients ranging in age from 18 to 28 years, diagnosed with at least 2 non-cavitated pit-and-fissure caries in the first and second molars were selected for this randomized split-mouth design trial. A total of 38 sealants, were placed. The teeth were sealed with NovaPro{u2122} Flow Hydroxyapatite Nanofiber reinforced flowable composite in one side, while Filtek{u2122} Z350 XT Flowable conventional resin-based composite on the contralateral. Each restoration was independently evaluated in terms of retention rate at 1, 6, and 12 months. Data were analyzed using Wilcoxon signed-rank test and Friedman{u2019}s test at p &lt; 0.05. The Results showed that NovaPro{u2122} Flow Hydroxyapatite showed complete retention with 100% at 1, 6, month evaluation periods, while Filtek{u2122} Z350 XT retention rates were 100%, 78.9%, respectively, for the same evaluation periods. At the 12-month recall, 2 (10.5%) total losses were observed in subjects treated with NovaPro{u2122} Flow and 2 total losses (15.8%) for Filtek{u2122} Z350 XT. No statistical significant difference in the retention rate in both sealants during different follow-up intervals (P&gt;0.05) Conclusions: The retention rate of both hydroxyapatite nanofibers reinforced flowable resin composite and the conventional nanofilled flowable resin composite after one year of follow up was comparable. Clinical relevance: The clinical survival rate of both tested materials may indicate them as effective approaches for preventing carious lesions in permanent teeth </subfield>
  </datafield>
  <datafield tag="530" ind1=" " ind2=" ">
    <subfield code="a">Issued also as CD</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2="4">
    <subfield code="a">Composite versus conventional resin-based</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2="4">
    <subfield code="a">Hydroxyapatite nano-fiber reinforced </subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2="4">
    <subfield code="a">Initially demineralized pits and fissure</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Mai Mamdouh Elsayed , </subfield>
    <subfield code="e">Supervisor</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Mona Ismail Riad , </subfield>
    <subfield code="e">Supervisor</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">http://172.23.153.220/th.pdf</subfield>
  </datafield>
  <datafield tag="905" ind1=" " ind2=" ">
    <subfield code="a">Asmaa</subfield>
    <subfield code="e">Cataloger</subfield>
  </datafield>
  <datafield tag="905" ind1=" " ind2=" ">
    <subfield code="a">Nazla</subfield>
    <subfield code="e">Revisor</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">ddc</subfield>
    <subfield code="c">TH</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">76436</subfield>
    <subfield code="d">76436</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="2">ddc</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">CUCL</subfield>
    <subfield code="b">cl210</subfield>
    <subfield code="d">2024-02-11</subfield>
    <subfield code="o">Cai01.09.03.M.Sc.2019.Sa.R</subfield>
    <subfield code="p">01010110080679000</subfield>
    <subfield code="r">2023-09-22 00:00:00</subfield>
    <subfield code="y">TH</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="2">ddc</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">CUCL</subfield>
    <subfield code="b">cl2u8</subfield>
    <subfield code="d">2024-02-11</subfield>
    <subfield code="o">Cai01.09.03.M.Sc.2019.Sa.R</subfield>
    <subfield code="p">01020110080679000</subfield>
    <subfield code="r">2023-09-22 00:00:00</subfield>
    <subfield code="t">80679.CD     </subfield>
    <subfield code="y">CD</subfield>
  </datafield>
</record>
