    <title>Reliability of secondary caries detection around composite restoration using light induced fluorescence in comparison to visual tactile method</title>
    <subTitle>Diagnostic accuracy study</subTitle>
  </titleInfo>
  <titleInfo type="alternative">
    <title>فاعلية تحديد التسوس الثانوى حول الحشوات الراتنجية المركبة باستخدام الكاميرا ذات الاشعاع الضوئى فى مقابل الطريقة الحسية البصرية</title>
    <subTitle>دراسة الدقة التشخيصية</subTitle>
  </titleInfo>
  <name type="personal">
    <namePart>Haneen Ahmed Shafik Elmoselhy</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Mohamed Fouad Haridy</namePart>
    <role>
      <roleTerm type="text">Supervisor</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Olfat Elsayed Hassanein</namePart>
    <role>
      <roleTerm type="text">Supervisor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">ua</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Cairo</placeTerm>
    </place>
    <publisher>Haneen Ahmed Shafik Elmoselhy</publisher>
    <dateIssued>2019</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>94 P. :  charts , photographs ;  25cm</extent>
  </physicalDescription>
  <abstract>Aim of the study : The aim of this study was to assess the reliability and reproducibility of secondary caries diagnosis using light induced fluorescence device  2Soprolife3 in comparison to conventional visual-tactile method according to modified USPHS restoration assessment Methodology : A total of 29 volunteer patients were assigned in this study. Each patient had at least one defected posterior occlusal resin composite restoration. The restoration was evaluated by two diagnostic methods; the visual tactile examination and assessment using the modified USPHS criteria  and the light fluorescence device SOPROLIFE (SOPRO, ACTEON Group, La Ciotat, France). This method involves an intraoral LED light-emitting diode camera offering the ability to detect and locate differences in density, structures, and/or chemical composition of hard tooth tissues.The blue LED, selected by the device, emits at a 450 nm-wavelength which excites a light fluorescence signal re-transmitted by dentine. The spectrum of the fluorescence signal is green when the dentine is healthy and dark red when the dentine is infected (according to the SOPROLIFE manufacturer{u2019}s instructions). According to modified United States Public Health Service  USPHS/ Ryge criteria Direct Clinical Evaluation of Restoration , which states the use of an eye without any magnification device, only a dental mirror and an explorer, in a proper isolated field following the directions to assess secondary caries existence. Prior to the initiation of the study, calibration sessions were arranged for the 3 operators using the two methods separately in the examination site</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Haneen Ahmed Shafik Elmoselhy ; Supervised Olfat Elsayed Hassanein , Mohamed Fouad Haridy</note>
  <note>Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry</note>
  <note>Issued also as CD</note>
  <subject>
    <topic>Light induced fluorescence </topic>
  </subject>
  <subject>
    <topic>Secondary caries  </topic>
  </subject>
  <subject>
    <topic>Visual tactile method </topic>
  </subject>
  <identifier type="uri">http://172.23.153.220/th.pdf</identifier>
  <location>
    <url>http://172.23.153.220/th.pdf</url>
  </location>
  <recordInfo>
    <recordContentSource authority="marcorg">EG-GiCUC</recordContentSource>
    <recordCreationDate encoding="marc">200227</recordCreationDate>
    <recordChangeDate encoding="iso8601">20250223032528.0</recordChangeDate>
    <languageOfCataloging>
      <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
    </languageOfCataloging>
  </recordInfo>
</mods>