A Head to Head Comparison between Computed Tomography Derived Fractional Flow Reserve and Single-Photon Emission Computerized Tomography in the Diagnosis of Myocardial Ischemia / by Mohamed Ahmed Zakaria Zaki Osemy ; Supervised Prof. Dr. Mohammad Ali Salem, Dr. Ahmed Hamdy Abdel Ghany Heussein, Dr. Ahmed Shehata Mohamed Ismail

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2025Description: 113 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • مقارنة بين تقييم ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية و التصوير المقطعي المحوسب أحادي الفوتون لتشخيص إقفار عضلة القلب [Added title page title]
Subject(s): DDC classification:
  • 616.0757
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2025. Summary: Myocardial ischemia is a significant global health concern with profound implications for morbidity and mortality. Accurate and timely diagnosis is critical for guiding appropriate clinical management and improving patient outcomes. Computed Tomography (CT)-derived fractional flow reserve (FFR) and Single- Photon Emission Computed Tomography (SPECT) represent two advanced non- invasive imaging modalities that aid in evaluating myocardial ischemia, particularly in patients with intermediate pre-test probability (PTP) of coronary artery disease (CAD). This study compared the diagnostic performance of CT-derived FFR and SPECT in detecting myocardial ischemia in 85 patients with intermediate PTP of CAD. Both modalities were assessed for sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall diagnostic accuracy. CT-derived FFR demonstrated high specificity (83.1%), exceptional NPV (92.8%), and an overall diagnostic accuracy of 80.9%, making it a reliable tool for ruling out myocardial ischemia. Subgroup analyses revealed variability in the performance of CT-derived FFR across different coronary territories, with the highest diagnostic accuracy observed for left anterior descending artery (LAD) ischemia. CT-derived FFR provides functional insights complementary to anatomical data from coronary CT angiography, offering a safe, efficient, and cost-effective alternative to invasive procedures. This study highlights the potential of CT- derived FFR as a preferred diagnostic tool in clinical settings, particularly for intermediate-risk patients. These findings underscore the importance of incorporating CT-derived FFR into routine practice to enhance diagnostic precision and improve patient outcomes. Summary: تبحث هذه الرسالة مقارنة مباشرة بين ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية و التصوير المقطعي المحوسب أحادي الفوتون لتشخيص إقفار عضلة القلب لدى المرضى الذين لديهم احتمال متوسط للإصابة بمرض الشريان التاجي. أُجريت الدراسة على ٩٤ مريضًا، وتم تقييم أداء كل من بين ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية و التصوير المقطعي المحوسب أحادي الفوتون من حيث الحساسية والدقة والقيمة التنبؤية الإيجابية والسلبية. أظهرت النتائج أن احتياطي الجريان الجزئي المستخلص من التصوير المقطعي يتمتع بدقة عالية في استبعاد نقص التروية القلبية (قيمة تنبؤية سلبية بلغت ٩٢.٨٪)، وحساسية ٧٠.٦٪ ودقة إجمالية بلغت ٨٠.٩٪، مما يجعله أداة فعالة وآمنة في تشخيص نقص التروية القلبية لدى المرضى ذوي المخاطر المتوسطة. أظهرت الدراسة أن ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية يتميز بتقديم رؤية تكاملية تجمع بين التقييم الوظيفي والتشريحي مقارنة بالتصوير النووي، الذي يعتمد بشكل أساسي على تقييم التروية القلبية باستخدام المواد المشعة. ومع ذلك، وجد أن أداء ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية يتفاوت بين الأوعية الشريانية، حيث أظهر أفضل دقة في تشخيص نقص التروية بالشريان الأمامي النازل مقارنة بالشرايين الأخرى. توصلت الدراسة إلى أن ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية يمثل خيارًا تشخيصيًا مبتكرًا وغير جراحي يمكن أن يقلل من الحاجة إلى التدخلات الجراحية غير الضرورية، خاصة في الحالات التي يتعذر فيها إجراء الاختبارات الغازية. ومع ذلك، يوصى بإجراء أبحاث إضافية تشمل مقارنة مباشرة مع الاحتياطي الجريان الجزئي الغازي لدعم هذه النتائج.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.31.M.Sc.2025.Mo.H (Browse shelf(Opens below)) Not for loan 01010110092500000

Thesis (M.Sc)-Cairo University, 2025.

Bibliography: pages 97-113.

Myocardial ischemia is a significant global health concern with profound
implications for morbidity and mortality. Accurate and timely diagnosis is critical
for guiding appropriate clinical management and improving patient outcomes.
Computed Tomography (CT)-derived fractional flow reserve (FFR) and Single-
Photon Emission Computed Tomography (SPECT) represent two advanced non-
invasive imaging modalities that aid in evaluating myocardial ischemia,
particularly in patients with intermediate pre-test probability (PTP) of coronary
artery disease (CAD).
This study compared the diagnostic performance of CT-derived FFR and SPECT
in detecting myocardial ischemia in 85 patients with intermediate PTP of CAD.
Both modalities were assessed for sensitivity, specificity, positive predictive
value (PPV), negative predictive value (NPV), and overall diagnostic accuracy.
CT-derived FFR demonstrated high specificity (83.1%), exceptional NPV
(92.8%), and an overall diagnostic accuracy of 80.9%, making it a reliable tool
for ruling out myocardial ischemia. Subgroup analyses revealed variability in the
performance of CT-derived FFR across different coronary territories, with the
highest diagnostic accuracy observed for left anterior descending artery (LAD)
ischemia.
CT-derived FFR provides functional insights complementary to anatomical data
from coronary CT angiography, offering a safe, efficient, and cost-effective
alternative to invasive procedures. This study highlights the potential of CT-
derived FFR as a preferred diagnostic tool in clinical settings, particularly for
intermediate-risk patients. These findings underscore the importance of
incorporating CT-derived FFR into routine practice to enhance diagnostic
precision and improve patient outcomes.

تبحث هذه الرسالة مقارنة مباشرة بين ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية و التصوير المقطعي المحوسب أحادي الفوتون لتشخيص إقفار عضلة القلب لدى المرضى الذين لديهم احتمال متوسط للإصابة بمرض الشريان التاجي.
أُجريت الدراسة على ٩٤ مريضًا، وتم تقييم أداء كل من بين ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية و التصوير المقطعي المحوسب أحادي الفوتون من حيث الحساسية والدقة والقيمة التنبؤية الإيجابية والسلبية. أظهرت النتائج أن احتياطي الجريان الجزئي المستخلص من التصوير المقطعي يتمتع بدقة عالية في استبعاد نقص التروية القلبية (قيمة تنبؤية سلبية بلغت ٩٢.٨٪)، وحساسية ٧٠.٦٪ ودقة إجمالية بلغت ٨٠.٩٪، مما يجعله أداة فعالة وآمنة في تشخيص نقص التروية القلبية لدى المرضى ذوي المخاطر المتوسطة.
أظهرت الدراسة أن ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية يتميز بتقديم رؤية تكاملية تجمع بين التقييم الوظيفي والتشريحي مقارنة بالتصوير النووي، الذي يعتمد بشكل أساسي على تقييم التروية القلبية باستخدام المواد المشعة. ومع ذلك، وجد أن أداء ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية يتفاوت بين الأوعية الشريانية، حيث أظهر أفضل دقة في تشخيص نقص التروية بالشريان الأمامي النازل مقارنة بالشرايين الأخرى.
توصلت الدراسة إلى أن ٳحتياطي التدفق الجزئي المشتق من الأشعة المقطعية يمثل خيارًا تشخيصيًا مبتكرًا وغير جراحي يمكن أن يقلل من الحاجة إلى التدخلات الجراحية غير الضرورية، خاصة في الحالات التي يتعذر فيها إجراء الاختبارات الغازية. ومع ذلك، يوصى بإجراء أبحاث إضافية تشمل مقارنة مباشرة مع الاحتياطي الجريان الجزئي الغازي لدعم هذه النتائج.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library