Image from OpenLibrary

Clinical evaluation of two fiber reinforced resin composites versus nanohybrid resin composite in posterior restorations : Randomized clinical trial / by Mohamed Hamdy Mohamed Kamal ; Supervision Prof. Dr. Rania Mosallam, Prof. Dr. Eman Abouauf.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2024Description: 128 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • التقييم السريرى لمركبان من الراتنج المقوى بالألياف مقابل مركب الراتنج النانوالهجين في الترميمات الخلفية: تجربة سريرية عشوائية [Added title page title]
Subject(s): DDC classification:
  • 617.695
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (Ph.D)-Cairo University, 2024. Summary: Aim: This study assessed the clinical performance of fiber reinforced resin composites either with short glass or polyethylene fibers compared to nanohybrid resin composite in restoration of class II MOD cavities over one-year follow-up period. Methodology: A total of 45 patients with 45 carious MOD lesions were recruited. Teeth were divided into three groups (n=15): Group (1): “fiber reinforcement” technique using short glass fiber reinforced resin composite (EverX Posterior) while Group (2): “fiber reinforcement” technique using polyethylene ribbon fibers (Ribbond-Ultra). Both groups (1) and (2) were layered with surface layer of nanohybrid composite (Filtek Z250). Group (3): Nanohybrid resin composite. The restorations were evaluated using the modified USPHS criteria at baseline, three, six, nine and 12 months. Intergroup and intragroup comparisons were performed using the Chi-Square test with statistical significance level set at (P ≤ 0.016). Results: There was no statistically significant difference between the three groups in all evaluated USPHS criteria at different follow-up periods except for color match. Short fiber reinforced restorations showed statistically significant less color match than other groups at different follow up periods; baseline, three, six, nine and 12 months. Conclusion: Direct fiber reinforced resin composite either with short glass or polyethylene ribbon fibers showed an acceptable clinical performance similar to nanohybrid resin composite in class II MOD restorations over the one-year follow-up period. Clinical significance: Fiber reinforcement techniques could be a viable restorative option for class II MOD cavities.Summary: يعد تطور تقوية الألياف أحد التحسينات في تقنية مركب الراتنج لدعم تطبيقاتها في الأسنان الخلفية ذات بنية الأسنان المتبقية المنخفضة إلى المتوسطة. يتم تعزيز نظام الحشو بتعزيز خارجي و داخلي بالألياف لمقاومة انتشار التشققات. يشتمل التعزيز الخارجي على مركب راتينج مقوى بألياف البولي إيثيلين )ريبوند(، في حين يشتمل التعزيز الداخلي على مركب راتينج مقوى بألياف زجاجية قصيرة يحتوي على ألياف زجاجية قصيرة متقطعة داخل نظام الحشو أجريت الدراسة الحالية لتقييم الأداء السريري لمادتين مختلفتين من المواد المركبة من الراتنج المقوى بالألياف )ألياف الزجاج القصيرة وألياف شريط البولي إيثيلين( في ترميم التجاويف من الدرجة الثانية الأنسية الأطباقية القاصية مقارنة بمركب الراتنج النانوي الهجين على مدار عام واحد. تم إجراء تصميم دراسة سريرية عشوائية على 45 تجاويف أنسية أطباقية قاصية من الدرجة الثانية في الأسنان الخلفية لدى 45 مريضًا بالغًا. لقد تلقوا بشكل عشوائي الأنواع الثلاثة من الترميمات ؛ أما أيفر اكس بوستريور )مركب راتينج مقوى بالألياف الزجاجية القصيرة(، أو ريبوند ألترا )مركب راتينج مقوى بألياف البولي إيثيلين( أو مركب راتنج النانو هجين بدون تقوية الألياف، تم تطبيق المواد وفقًا لتعليمات الشركات المصنعة، تم تقييم الترميمات بعد الترميم مباشرة، بعد ثلاثة ، ستة، تسعة أشهر وبعد عام واحد من قبل اثنين من المقيمين المدربين طبقا لنظام التقييم بالمعايير المعدلة للولايات المتحدة. تم استخدام اختبار مربع كاي للمقارنة بين أنواع الترميمات على فترات زمنية مختلفة و ذلك بعد تصحيح بونفيروني وتم تعيين مستوى الدلالة الإحصائية عند 0.05) ≤ (P و تم تعيين حد الثقة عند 95 ٪ مع قوة .80 وأظهرت النتائج عدم وجود فروق ذات دلالة إحصائية بين جميع المواد لجميع نتائج الاختبار. تم العثور على اختلافات كبيرة في تطابق اللون للفترات الزمنية المختلفة لصالح كل من المجموعات المركبة من الراتنج المقوى بالبولي إيثيلين والمجموعات المركبة من الراتنج النانو هجين. وبناءً على نتائج الدراسة، تم التوصل إلى أن مركب الراتينج المقوى بالألياف سواء بألياف البولي إيثيلين او الزجاجية القصيرة يمكن أن يكون مفيدًا في ترميم التجاويف الخلفية من الدرجة الثانية الأنسية الأطباقية القاصية.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.03.Ph.D.2024.Mo.C (Browse shelf(Opens below)) Not for loan 01010110092002000

Thesis (Ph.D)-Cairo University, 2024.

Bibliography: pages 119-127.

Aim: This study assessed the clinical performance of fiber reinforced resin composites either with short glass or polyethylene fibers compared to nanohybrid resin composite in restoration of class II MOD cavities over one-year follow-up period.
Methodology: A total of 45 patients with 45 carious MOD lesions were recruited. Teeth were divided into three groups (n=15): Group (1): “fiber reinforcement” technique using short glass fiber reinforced resin composite (EverX Posterior) while Group (2): “fiber reinforcement” technique using polyethylene ribbon fibers (Ribbond-Ultra). Both groups (1) and (2) were layered with surface layer of nanohybrid composite (Filtek Z250). Group (3): Nanohybrid resin composite. The restorations were evaluated using the modified USPHS criteria at baseline, three, six, nine and 12 months. Intergroup and intragroup comparisons were performed using the Chi-Square test with statistical significance level set at (P ≤ 0.016).
Results: There was no statistically significant difference between the three groups in all evaluated USPHS criteria at different follow-up periods except for color match. Short fiber reinforced restorations showed statistically significant less color match than other groups at different follow up periods; baseline, three, six, nine and 12 months.
Conclusion: Direct fiber reinforced resin composite either with short glass or polyethylene ribbon fibers showed an acceptable clinical performance similar to nanohybrid resin composite in class II MOD restorations over the one-year follow-up period.
Clinical significance: Fiber reinforcement techniques could be a viable restorative option for class II MOD cavities.

يعد تطور تقوية الألياف أحد التحسينات في تقنية مركب الراتنج لدعم تطبيقاتها في الأسنان الخلفية ذات بنية الأسنان المتبقية المنخفضة إلى المتوسطة. يتم تعزيز نظام الحشو بتعزيز خارجي و داخلي بالألياف لمقاومة انتشار التشققات. يشتمل التعزيز الخارجي على مركب راتينج مقوى بألياف البولي إيثيلين )ريبوند(، في حين يشتمل التعزيز الداخلي على مركب راتينج مقوى بألياف زجاجية قصيرة يحتوي على ألياف زجاجية قصيرة متقطعة داخل نظام الحشو
أجريت الدراسة الحالية لتقييم الأداء السريري لمادتين مختلفتين من المواد المركبة من الراتنج المقوى بالألياف )ألياف
الزجاج القصيرة وألياف شريط البولي إيثيلين( في ترميم التجاويف من الدرجة الثانية الأنسية الأطباقية القاصية مقارنة بمركب الراتنج النانوي الهجين على مدار عام واحد.
تم إجراء تصميم دراسة سريرية عشوائية على 45 تجاويف أنسية أطباقية قاصية من الدرجة الثانية في الأسنان الخلفية لدى 45 مريضًا بالغًا. لقد تلقوا بشكل عشوائي الأنواع الثلاثة من الترميمات ؛ أما أيفر اكس بوستريور )مركب راتينج مقوى بالألياف الزجاجية القصيرة(، أو ريبوند ألترا )مركب راتينج مقوى بألياف البولي إيثيلين( أو مركب راتنج النانو هجين بدون تقوية الألياف، تم
تطبيق المواد وفقًا لتعليمات الشركات المصنعة، تم تقييم الترميمات بعد الترميم مباشرة، بعد ثلاثة ، ستة، تسعة أشهر وبعد عام واحد
من قبل اثنين من المقيمين المدربين طبقا لنظام التقييم بالمعايير المعدلة للولايات المتحدة. تم استخدام اختبار مربع كاي للمقارنة بين أنواع الترميمات على فترات زمنية مختلفة و ذلك بعد تصحيح بونفيروني وتم تعيين مستوى الدلالة الإحصائية عند 0.05) ≤ (P و تم تعيين حد الثقة عند 95 ٪ مع قوة .80
وأظهرت النتائج عدم وجود فروق ذات دلالة إحصائية بين جميع المواد لجميع نتائج الاختبار. تم العثور على اختلافات كبيرة في تطابق اللون للفترات الزمنية المختلفة لصالح كل من المجموعات المركبة من الراتنج المقوى بالبولي إيثيلين والمجموعات المركبة من الراتنج النانو هجين.
وبناءً على نتائج الدراسة، تم التوصل إلى أن مركب الراتينج المقوى بالألياف سواء بألياف البولي إيثيلين او الزجاجية القصيرة يمكن أن يكون مفيدًا في ترميم التجاويف الخلفية من الدرجة الثانية الأنسية الأطباقية القاصية.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library