000 01699cam a2200337 a 4500
003 EG-GiCUC
005 20250223030522.0
008 111130s2011 ua e f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.13.05.M.Sc.2011.Ha.D
100 0 _aHazem Hossam Eldin Elanwar
245 1 0 _aDynamic identification for linear stsems using numerical and analytical approaches /
_cHazem Hossam Eldin Elanwar ; Supervised Hesham S. Sayed , M. Hassanien Serror
246 1 5 _aتعيين معامل الأضمحلال باستخدام الطرق التحليلية و المعملية
260 _aCairo :
_bHazem Hossam Eldin Elanwar ,
_c2011
300 _a93 P. :
_bplans ;
_c30cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering
520 _aDamping ratio became one of the most important factors that govern the structural response due to lateral loads. Despite its significance, there is no accurate mathematical representation for it. This research aims to develop a procedure that identifies the damping ratio using system identification technique and measured dynamic responses. The proposed procedure was applied on a laboratory experiment utilizing shaking table device
530 _aIssued also as CD
653 4 _aDamping identification
653 4 _aLaboratory experiment
653 4 _aShaking table
700 0 _aHesham Sobhy Sayed ,
_eSupervisor
700 0 _aMohamed Hassanien Serror ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aSamia
_eCataloger
942 _2ddc
_cTH
999 _c36401