| 000 | 02706cam a2200349 a 4500 | ||
|---|---|---|---|
| 003 | EG-GiCUC | ||
| 005 | 20250223032057.0 | ||
| 008 | 181010s2018 ua dh f m 000 0 eng d | ||
| 040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
| 041 | 0 | _aeng | |
| 049 | _aDeposite | ||
| 097 | _aM.Sc | ||
| 099 | _aCai01.11.24.M.Sc.2018.Mo.I | ||
| 100 | 0 | _aMohammad Ashraf Bakr | |
| 245 | 1 | 0 |
_aIncidence of posterior vitreous detachment in patients undergoing femtosecond laser-assisted in-situ keratomileusis using a 200 KHZ femtosecond laser system / _cMohammad Ashraf Bakr ; Supervised Mohamed Hassan Hosny , Mohamed Anis , Sara Azzam |
| 246 | 1 | 5 | _aنسبة حدوث انفصال الجسم الزجاجي في مرضى الفمتوليزك بإستخدام جهاز فمتوليزر ذو تردد 200 كيلوهرتز |
| 260 |
_aCairo : _bMohammad Ashraf Bakr , _c2018 |
||
| 300 |
_a95 P. : _bcharts , facsimiles ; _c25cm |
||
| 502 | _aThesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology | ||
| 520 | _aBackground : Myopic patients develop excessive vitreous liquefaction at a younger age. This is not matched with loosening of vitreoretinal adhesions. PVD can result in many retinal complications including retinal tears, RD and ERM. PVD can occur after LASIK as a result of the suction applied during flap creation. This is higher with mechanical microkeratomes compared to femtosecond laser systems. The incidence of PVD after LASIK ranges between 9.5 and 21% with mechanical microkeratomes and between 16% and 27% with iFS-60 and 85% with iFS-150 femtosecond laser systems.Purpose: To determine incidence of PVD after FS-LASIK using Alcon Wavelight FS-200.Methods: This is a prospective clinical trial that was conducted on 30 eyes of 15 patients in the interval between June 2017 and March 2018. Patients with no evidence of preoperative PVD using dynamic B-scan US underwent FS-LASIK. Postoperative dynamic B-scan US was repeated 3 weeks later to determine whether PVD developed.Results: Only 3 eyes developed PVD postoperatively with an incidence of 10%.Conclusion: Incidence of PVD following FS-LASIK using Alcon wavelight FS-200 is lower than that reported with other femtosecond laser systems with lower frequency | ||
| 530 | _aIssued also as CD | ||
| 653 | 4 | _a200 KHZ femtosecond laser system | |
| 653 | 4 | _aFemtosecond-assisted laser in situ keratomelieusis | |
| 653 | 4 | _aPosterior vitreous detachment | |
| 700 | 0 |
_aMohamed Anis , _eSupervisor |
|
| 700 | 0 |
_aMohamed Hassan Hosny , _eSupervisor |
|
| 700 | 0 |
_aSara Azzam , _eSupervisor |
|
| 856 | _uhttp://172.23.153.220/th.pdf | ||
| 905 |
_aEnas _eCataloger |
||
| 905 |
_aNazla _eRevisor |
||
| 942 |
_2ddc _cTH |
||
| 999 |
_c67893 _d67893 |
||