000 03268cam a2200349 a 4500
003 EG-GiCUC
005 20250223032239.0
008 190407s2018 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.17.06.M.Sc.2018.Sh.A
100 0 _aShimaa Ali Elshahat Elkima
245 1 0 _aAssessment of selected determinants of nurses compliance to infection control guidelines in gastrointestinal endoscopy units =
_bتقييم محددات مختارة لالتزام ممرضى المناظير بارشادات مكافحة العدوى فى وحدات مناظير الجهاز الهضمى /
_cShimaa Ali Elshahat Elkima ; Supervised Khairia Abo Bakr Elsawi , Mervat Gaber Elanany , Naglaa Fathy Afifi Youssef
246 1 5 _aتقييم محددات مختارة لالتزام ممرضى المناظير بارشادات مكافحة العدوى فى وحدات مناظير الجهاز الهضمى
260 _aCairo :
_bShimaa Ali Elshahat Elkima ,
_c2018
300 _a104 + 14 Leaves :
_bcharts , facsimiles ;
_c30cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Nursing - Department of Surgical Nursing
520 _aBackground: Gastrointestinal endoscopy (GIE) is a widely performed procedure for the diagnosis and treatment of gastrointestinal diseases. The risk of infection for patients undergoing these procedures has been progressively reduced by the implementation of infection control guidelines and adequate training of nursing staff. Therefore the current study was conducted to assess the selected determinants of nurses{u2019} compliance to infection control guidelines in gastrointestinal endoscopy units. Methods: A convenient sample of 30 nurses working at three selected endoscopy units at three of the biggest teaching hospitals in Cairo Governorate were recruited to fulfil the aim of this study. A descriptive, exploratory research design was utilized. Three tools were used to collect the data: (i) semi structured interview questionnaire, (ii) observational checklist for nurses{u2019} practice and (iii) microbiological report.Results:76.7% of the subjects were females with a mean of age 39.8± 7.7 years. All of them hold secondary school nursing diploma. 73.3% had un-satisfactory level of knowledge in accordance with the national guideline for the endoscope reprocessing. More than 90%of them had unsatisfactory performance level in all the eight reprocessing steps, and 76.66% had unsatisfactory level in the storage step. There was a statistically significant difference (p < 0.05) across the three endoscopy units. Out of 44 endoscope swabs, 27.27% were positive for Pseudomonas Aeruginosa and Staph Aureus before and after using the endoscope suggesting presence of biofilms,
530 _aIssued also as CD
653 4 _aEndoscope reprocessing
653 4 _aInfection control
653 4 _aNurses{u2019} compliance
700 0 _aKhairia Abobakr Elsawi ,
_eSupervisor
700 0 _aMervat Gaber Elanany ,
_eSupervisor
700 0 _aNaglaa Fathy Afifi Youssef ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aEnas
_eCataloger
905 _aNazla
_eRevisor
942 _2ddc
_cTH
999 _c71270
_d71270