000 02979cam a2200349 a 4500
003 EG-GiCUC
005 20250223032316.0
008 190615s2018 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.11.09.Ph.D.2018.Wa.S
100 0 _aWalid Shehatta Hassan
245 1 0 _aSmart touch radiofrequency catheter ablation versus cryoballoon ablation of pulmonary veins in patients with paroxysmal AF /
_cWalid Shehatta Hassan ; Supervised Sherif Hamed , Kahled Hussein , Motaz Elhalag
246 1 5 _aالذبذبة الأذينية ما بين الكى الحرارى بموجات الراديو مستخدما قسطرة ذات خاصية إستشعار الضغط والكى بالتبريد
260 _aCairo :
_bWalid Shehatta Hassan ,
_c2018
300 _a186 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Critical Care Medicine
520 _aAims Evaluation of the safety and efficacy of PVI in PAF patients using two new different technologies, cryoballoon ablation and RFA with contact force-sensing catheters. Methods and results We performed a prospective single centre non-randomized controlled clinical trial that was conducted during the period between January 2016 and June 2018 in Critical Care Medicine Department{u2013} Cairo University.Twenty patients were enrolled in this study and were subjected to standardized PVI using RFA with CF sensing catheter (Thermocool® SmartTouch{u2122}, Biosense Webster (CF group, n=10 patients) and CB ablation (Arctic Front Advance{u2122}, Medtronic)(CB group n=10 patients).Twelve months follow up was used to assess procedure long term outcome and complications rate. Procedure duration was significantly shorter for CB group than for CF group (171.7+15.24 vs. 199.3+18.94 min, P = 0.002), however fluoroscopy duration and X-ray exposure were longer in CB group than CF group , however was not statistically significant (P = 0.1 and P = 0.22, respectively). Overall complication rate was similar in both groups: 2 (20%) in each group. Transient right phrenic nerve palsy occurred only in CB group (1 patient,10% vs none in the CF group); and transient ischemic acute stroke occurred only in one patient of the CB group (10% vs none in the CF group) ,severe non-lethal complications (Tamponade, and the uncommon complication, entrapment of circular mapping catheter into mitral valve ) occurred only in CF group (2 patients, 20%)
530 _aIssued also as CD
653 4 _aParoxysmal atrial fibrillation
653 4 _aPulmonary veins
653 4 _aRadiofrequency
700 0 _aKahled Hussein ,
_eSupervisor
700 0 _aMotaz Elhalag ,
_eSupervisor
700 0 _aSherif Hamed ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c72453
_d72453