| 000 | 02988cam a2200337 a 4500 | ||
|---|---|---|---|
| 003 | EG-GiCUC | ||
| 005 | 20250223032448.0 | ||
| 008 | 191126s2019 ua do f m 000 0 eng d | ||
| 040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
| 041 | 0 | _aeng | |
| 049 | _aDeposite | ||
| 097 | _aM.Sc | ||
| 099 | _aCai01.09.13.M.Sc.2019.Mo.A | ||
| 100 | 0 | _aMohammed Mohammed Ahmed Elhag Ibrahim | |
| 245 | 1 | 0 |
_aAssessment of the accuracy of surgical guide designed from cbct with different voxel sizes in computer guided implantology : _bRandomized clinical trial / _cMohammed Mohammed Ahmed Elhag ; Supervised Mushira M. Dahaba , Ahmed M. Abdalsamad |
| 246 | 1 | 5 |
_aتقييم دقة الدليل الجراحى المصمم من التصوير المقطعى بالحاسوب مخروطى الشعاع باستخدام عناصر حجمية مختلفة فى زرع الأسنان بمعاونة الحاسوب : _bتجربة سريرية عشوائية |
| 260 |
_aCairo : _bMohammed Mohammed Ahmed Elhag Ibrahim , _c2019 |
||
| 300 |
_a72 P. : _bcharts , photographs ; _c25cm |
||
| 502 | _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery | ||
| 520 | _aObjectives:The present study was designed to assess the effect of CBCT with different voxel sizes on the accuracy of surgical guide fabrication on computer guided implantolog. Material and methods:This study was conducted on eight patients selected from outpatient clinic, Faculty of dentistry, Cairo university. The patients were divided into two groups. One group received dental implants using surgical guides designed from CBCT with 0.2 mm voxel size while the other group received dental implants using surgical guides designed from CBCT with 0.4 mm voxel size. The surgical guides were designed using bluesky bio software. The patients were asked for post-operative CBCT to compare the accuracy the surgical guide. Linear and angular deviations were measured between planned and actual position in both groups. The results were tabulated and statistically analyze.Results:Surgical guides manufactured with CBCT of 0.2 mm voxel size showed statistically significantly lower median linear and angular deviation than surgical guides manufactured with CBCT of 0.4 mm voxel in BL direction. While there was no statistically significantly difference between the two groups in linear and angular deviation in MD direction. Conclusion: There was no clinical significantly clinical difference in linear and angular accuracy between surgical guides manufactured from CBCT with voxel size either 0.2mm or 0.4 mm | ||
| 530 | _aIssued also as CD | ||
| 653 | 4 | _aComputer guided implantology | |
| 653 | 4 | _aImplant | |
| 653 | 4 | _aSurgical guides | |
| 700 | 0 |
_aAhmed Mohamed Abdalsamad , _eSupervisor |
|
| 700 | 0 |
_aMushira Mohamed Dahaba , _eSupervisor |
|
| 856 | _uhttp://172.23.153.220/th.pdf | ||
| 905 |
_aNazla _eRevisor |
||
| 905 |
_aSamia _eCataloger |
||
| 942 |
_2ddc _cTH |
||
| 999 |
_c75483 _d75483 |
||