000 03113cam a2200337 a 4500
003 EG-GiCUC
005 20250223032529.0
008 200229s2019 ua dho f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.09.09.Ph.D.2019.Mo.E
100 0 _aMohamed Mamdouh Afify
245 1 0 _aEvaluation of patient satisfaction and biting force of new design of extracoronal castable precision attachment (OT unilateral attachment) versus conventional partial denture for treatment of unilateral mandibular distal extension area :
_ba randomized controlled trial /
_cMohamed Mamdouh Afify ; Supervied Nadia Ahmed Abbas , Mostafa Helmy Mostafa
246 1 5 _aتقيم درجه رضاء وقوة العضة للمرضى المعالجين بطريقة جديدة لتثبيت التركيبات الجزئيه بالوصلات مقارنة بالتركيبات الجزئية المثبتة بمشابك فى علاج حالات فقدان الاسنان بالفك السفلى فى جانب واحد
260 _aCairo :
_bMohamed Mamdouh Afify ,
_c2019
300 _a126 P. :
_bcharts , facsimiles , photoghraphs ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aThis study was conducted on sixteen patients with unilateral mandibular distal extension area with second premolar is the last abutment teeth. This study aimed to evaluate patient satisfaction and biting force of patients with unilateral mandibular distal extension area treated with two different design of removable partial denture. The patients were divided into two equal groups, group I received conventional removable partial denture which provides cross arch stabilization and a double aker clasp was fabricated.Group II received new design of extracoronal castable precision attachment (OT Unilateral attachment). Patients of both groups were evaluated at the time of prosthesis insertion, three, six and twelve months later. Evaluation included patient satisfaction by and biting force by load star sensor. Results at the end of follow up period showed statistically significant increase in group II (OT unilateral design) in patient satisfaction and biting force and it was more comfortable and satisfactory tolerated by patients than conventional partial denture. From the results of this study, it was concluded that: It's preferable to use the new design of extracoronal castable precision attachment (OT UNILATERAL) being simpler, more comfortable to the patients and give high masticatory efficiency in the form of biting force than conventional removable partial denture
530 _aIssued also as CD
653 4 _aBiting force
653 4 _aConventional partial denture
653 4 _aOT Unilateral attachment
700 0 _aMostafa Helmy Mostafa ,
_eSupervisor
700 0 _aNadia Ahmed Abbas ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c76821
_d76821