000 03168cam a2200349 a 4500
003 EG-GiCUC
005 20250223032635.0
008 201123s2020 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.11.24.Ph.D.2020.Al.C
100 0 _aAliaa Ahmed Farag Ahmed Farag Ahmed
245 1 0 _aCorrelation of stem cell count to the survival of micro fat grafts in augmenting the enophthalmic socket volume:
_bA CT volumetry guided study /
_cAliaa Ahmed Farag Ahmed Farag Ahmed ; Supervised Tamer Ismail Gawdat , Rania Ahmed Abdel Salam , Laila Ahmed Rashed
246 1 5 _aمقارنة بين إرتباط عدد الخلايا الجزعية ببقاء الرقع الدهنيه المجهرية في زيادة حجم الحجاج الذى يعانى من العين الضامره بإستخدام الأشعة المقطعية لحساب الحجم
260 _aCairo :
_bcharts,facsmilies ,
_c2020
300 _a129 P . :
_bAliaa Ahmed Farag Ahmed Farag Ahmed ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 _aBackground: The use of autologous fat grafting is limited by its unpredictable survival rate. In our study we aim at studying the effect of stem cell viability, harvested from the abdomen and thigh, on autologous fat grafts{u2019} survival in the orbital for treating the enophthalmic anophthalmic socket using CT volumetry. Methods: A randomized prospective interventional study including 24 patients suffering from unilateral enophthalmic anophthalmic socket. Pre-operative clinical assessment included photographs, exophthalmometry reading as well as CT volumetry for volume deficit calculations. The harvesting site was randomly allocated between patients (abdomen or thigh). Fat was sent to the laboratory to assess stem cell viabilityPatients were followed up to 6 months post-operatively. Percentage of fat retained 1 and 2 (Percentage of fat remaining at the last follow up compared to pre-operative measurements of the enophthalmic socket with the globe and without the globe respectively) was calculated as well as exophthalmometry change. Results: Mean percentage of retained fat 1 and 2 were 14.75% & 25.31% respectively. No statistically significant correlation was found between the sex, age of the patients, donor site, percentage of fat retained 1 and 2 or exophthalmometer change and the percentage of stem cell viability. Difficulty of extraction and degree of atrophia correlated significantly with percentage of fat retained 2 and not 1. Exophthalmometer change correlated significantly with percentage of fat retained 1 and not 2
530 _aIssued also as CD
653 4 _aEnophthalmic socket volume
653 4 _aMicro fat grafts
653 4 _aStem cell count
700 0 _aLaila Ahmed Rashed ,
_eSupervisor
700 0 _aRania Ahmed Abdel Salam ,
_eSupervisor
700 0 _aTamer Ismail Gawdat ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aAmira
_eCataloger
905 _aNazla
_eRevisor
942 _2ddc
_cTH
999 _c78924
_d78924