000 03025cam a2200337 a 4500
003 EG-GiCUC
005 20250223032636.0
008 201128s2019 ua dho f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2019.Ra.I
100 0 _aRawan Ferroukhi
245 1 0 _aImpact of digital photography and conventional method on the accuracy of shade matching in the esthetic zone :
_bIn vivo study /
_cRawan Ferroukhi ; Supervised Omaima Elmahallawi , Ahmed Naguib
246 1 5 _aتأثير التصوير الرقمى والطريقة التقليدية على دقة مطابقة اللون في المنطقة الجمالية :
_bدراسة إكلينكية
260 _aCairo :
_bRawan Ferroukhi ,
_c2019
300 _a123 P. :
_bcharts , facimimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aNowadays, patients{u2019} demands have increased toward esthetics therefore, construction of a highly esthetic restoration is mandatory. Shade selection is the crucial part of esthetic dentistry which requires full understanding of color science and teeth surface characterization.This clinical study was performed in order to evaluate the accuracy of digital photography and spectrophotometer in optimizing shade matching when compared to conventional method of shade selection. A total of nine patients, requiring restorations in the esthetic zone, were included in this study. Each patient received three crowns representing three groups according to the different shade matching method used. Group (V3D) as a control group: VITA 3D-Master shade guide, Group (VE) as the first intervention: VITA Easy shade V spectrophotometer and Group (D) as the second Intervention : Digital photography with Adobe Photoshop software.The shade of the contralateral/adjacent tooth was obtained visually with the use of VITA 3D-Master shade guide, under three different light conditions to avoid metamerism.This was carried out after the five prosthodontists were examined for color blindness using Ishtar{u2019}s test. Shade was also selected using Vita Easyshade V spectrophotometer.The tooth area was selected from the device, on a natural tooth (adjacent/contralateral) on the middle- middle 1/3 of the labial surface of the tooth for the true hue and block shade. Then, a 3spot mode shade mapping was also measured on the (cervical, middle and incisal thirds).The measurement was accepted when 5 consecutive, identical readings were generated for each area
530 _aIssued also as CD
653 4 _aCervical, middle and incisal thirds
653 4 _aDigital Photography
653 4 _aEsthetic Zone
700 0 _aAhmed Naguib ,
_eSupervisor
700 0 _aOmaima Elmahallawi ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c78977
_d78977