000 03240cam a2200337 a 4500
003 EG-GiCUC
005 20250223032648.0
008 201228s2019 ua dho f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2019.Ma.M
100 0 _aMarwa Magdy Abueleneen
245 1 0 _aMarginal accuracy of zirconium reinforced lithium silicate (VITA SUPRINITY) crowns with two marginal designs before and after cementation under thermomechanical cycling :
_bIn vitro study /
_cMarwa Magdy Abueleneen ; Supervised Gihan Abdelhady Elnaggar , Maha Ahmed Taymour
246 1 5 _aدقة الحواف لطرابيش سيراميك الليثيوم سيليكات المقوى بالزيركونيا (فيتا سبرينيتى) بخطين نهاية مختلفين قبل و بعد اللصق عند تعرضهم للضغط الحرارى الدورى :
_bدراسة معملية
260 _aCairo :
_bMarwa Magdy Abueleneen ,
_c2019
300 _a94 P. :
_bcharts , facimiles , photoghrphs ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aAim: This in vitro study was carried out to assess the marginal accuracy of VITA SUPRINITY crowns which were prepared with conservative feather edge margin design (intervention) compared to deep chamfer margin design (control). Materials and Methods: twenty crowns were constructed which were divided into two equal groups, Group (I): Ten crowns (n=10) fabricated with deep chamfer marginal design (control), Group (II): Ten crowns (n=10) fabricated with feather edge marginal design. Two stainless steel dies were constructed, one die was prepared with deep chamfer marginal design (0.7mm) and the other with feather edge marginal design (0.25mm). Then each die was duplicated into ten epoxy resin dies (for each group). After that, each die was scanned then crowns were milled. Crowns were then seated on their epoxy resin dies and then marginal gap was measured by scanning electron microscope (SEM). Crowns were then cemented by adhesive resin cement. All samples were subjected to thermo-mechanical aging. After that, marginal gap was then measured by the same way. Data was recorded, tabulated and statistically analyzed. Results: With regard to the effect of margin design, It was found that deep chamfer margin design recorded statistically non-significant higher marginal gap mean value (27.20 ± 3.52 æm) than feather edge design (26.21 ± 1.49 æm).Irrespective of the margin of preparation design, Marginal gap before cementation recorded lower mean value (11.89±2.13 æm) than after cementation under thermo-mechanical aging (41.97 ± 3.68 æm) and this was statistically significant as indicated by paired t-test (p=<0.0001< 0.05)
530 _aIssued also as CD
653 4 _aFeather edge finish line
653 4 _aGlass ceramics
653 4 _aMarginal fit
700 0 _aGihan Abdelhady Elnaggar ,
_eSupervisor
700 0 _aMaha Ahmed Taymour ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c79364
_d79364