| 000 | 02825cam a2200349 a 4500 | ||
|---|---|---|---|
| 003 | EG-GiCUC | ||
| 005 | 20250223032652.0 | ||
| 008 | 210109s2020 ua dh f m 000 0 eng d | ||
| 040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
| 041 | 0 | _aeng | |
| 049 | _aDeposite | ||
| 097 | _aPh.D | ||
| 099 | _aCai01.11.24.Ph.D.2020.Ma.A | ||
| 100 | 0 | _aMarian Girgis Soliman Mikhael | |
| 245 | 1 | 0 |
_aAssessment of safety, efficacy and predictability of a trifocal intra-ocular lens / _cMarian Girgis Soliman Mikhael ; Supervised Mohamed Abdelmonem Hassaballa , Amr Abdellatif Osman , Sherif Ahmed Mostafa Eissa |
| 246 | 1 | 5 | _aتقييم أمان وفاعلية وتوقعية عدسة ثلاثية البؤرة |
| 260 |
_aCairo : _bMarian Girgis Soliman Mikhael , _c2020 |
||
| 300 |
_a97 P. : _bcharts , facsimiles ; _c25cm |
||
| 502 | _aThesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology | ||
| 520 | _aAcrySof PanOptix trifocal IOL is one of the latest presbyopia correcting IOLs based on an optical technology which is different from other traditional trifocal IOLs, it is designed to help patients accomplish near and intermediate tasks with greater ease especially, at intermediate distance 60 cm not 80 cm. Our aim is to evaluate the performance of PanOptix trifocal IOL in terms of safety, efficacy, predictability and to compare contrast sensitivity, quality of vision and the aberrations induced between PanOptix trifocal IOL and Acrysof monofocol IOL. Methods :- our study is a prospective interventional non randomized study conducted on 38 eyes, 21 patients underwent phacoemulsification divided into 2 groups, group (A) implanted with PanOptix trifocal IOL,and group ( B) implanted with AcrySof monofocal IOL. Results:- PanOptix showed excellent safety, efficacy and predictability. In comparison to the monofocal group, contrast sensitivity was slightly impaired without affecting the daily activities of the patients. In addition, spectacle independence was significantly higher in the group implanted with PanOptix than the monofocal group. Conclusion :- we conclude that the success of implantation of AcrySof PanOptix IOL depends on many criteria to be fulfilled; like choosing the suitable biometry formula, thorough pre operative assessment including anterior and posterior segment examination, corneal topography, and choosing the best candidate | ||
| 530 | _aIssued also as CD | ||
| 653 | 4 | _aPanOptix | |
| 653 | 4 | _aPresbyopia | |
| 653 | 4 | _aTrifocal intra ocular lenses | |
| 700 | 0 |
_aAmr Abdellatif Osman , _eSupervior |
|
| 700 | 0 |
_aMohamed Abdelmonem Hassaballa , _eSupervior |
|
| 700 | 0 |
_aSherif Ahmed Mostafa Eissa , _eSupervior |
|
| 856 | _uhttp://172.23.153.220/th.pdf | ||
| 905 |
_aNazla _eRevisor |
||
| 905 |
_aShimaa _eCataloger |
||
| 942 |
_2ddc _cTH |
||
| 999 |
_c79488 _d79488 |
||