| 000 | 02862cam a2200349 a 4500 | ||
|---|---|---|---|
| 003 | EG-GiCUC | ||
| 005 | 20250223032758.0 | ||
| 008 | 210802s2020 ua dh f m 000 0 eng d | ||
| 040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
| 041 | 0 | _aeng | |
| 049 | _aDeposite | ||
| 097 | _aPh.D | ||
| 099 | _aCai01.11.25.Ph.D.2020.Mo.E | ||
| 100 | 0 | _aMohamed Abdelsamie Khalefa | |
| 245 | 1 | 0 |
_aEvaluation of novel quadrilateral surface plates in management of acetabular fractures : _bAccuracy of reduction and early functional outcomes with A minimum Of 1 year follow up / _cMohamed Abdelsamie Khalefa ; Supervised Khaled Fawzy M. Abdelkader , Mahmoud Abdelkarim , Walid Elnahal |
| 246 | 1 | 5 |
_aتقييم الشرائح السطحية الرباعية المبتكرة فى علاج كسور الحُق الحُرقفى جراحياً : _bدقة رد الكسور والنتائج الوظيفية والاشعاعية المبكرة مع متابعة لمدة عام كحد أدنى |
| 260 |
_aCairo : _bMohamed Abdelsamie Khalefa , _c2020 |
||
| 300 |
_a206 P. : _bcharts , facsimiles ; _c25cm |
||
| 502 | _aThesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopaedic Surgery | ||
| 520 | _aFractures involving both columns of the acetabulum are challenging particularly those with quadrilateral plate (QLP) involvement, as it adds on more burden to anatomical reconstruction and fixation. Additionally we are seeing more comminuted and osteoporotic acetabular fractures due to the rise in the numbers of elderly population. A variety of implants have been developed to address the problem of displaced quadrilateral plate fractures recently, including anterior intrapelvic approach (AIP) specific instruments and anatomic suprapectineal quadrilateral surface plating system (QLS) yet with limited published evidence. This study suggested that using novel approach specific instruments and anatomical pre-shaped plates through anterior intra-pelvic approach, has led to anatomical reduction in 82% of the cases on post-operative CT scans with 69% excellent and very good functional outcome at 1 year follow up, and a low complication rate. Older age was associated with poorer radiological and functional outcomes. Larger scale randomised control studies with longer term follow up are recommended to establish the effectiveness of these plates against the conventional ones | ||
| 530 | _aIssued also as CD | ||
| 653 | 4 | _aManagement of acetabular fractures | |
| 653 | 4 | _aQuadrilateral plate (QLP) | |
| 653 | 4 | _aQuadrilateral surface plating system (QLS) | |
| 700 | 0 |
_aKhaled Fawzy M. Abdelkader , _eSupervisor |
|
| 700 | 0 |
_aMahmoud Abdelkarim , _eSupervisor |
|
| 700 | 0 |
_aWalid Elnahal , _eSupervisor |
|
| 856 | _uhttp://172.23.153.220/th.pdf | ||
| 905 |
_aNazla _eRevisor |
||
| 905 |
_aShimaa _eCataloger |
||
| 942 |
_2ddc _cTH |
||
| 999 |
_c81585 _d81585 |
||